SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Bruze M.) srt2:(2005-2009)"

Sökning: WFRF:(Bruze M.) > (2005-2009)

  • Resultat 1-10 av 19
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • Diepgen, T. L., et al. (författare)
  • Hand eczema classification: a cross-sectional, multicentre study of the aetiology and morphology of hand eczema
  • 2009
  • Ingår i: British Journal of Dermatology. - : Oxford University Press (OUP). - 1365-2133 .- 0007-0963. ; 160:2, s. 353-358
  • Tidskriftsartikel (refereegranskat)abstract
    • Hand eczema is a long-lasting disease with a high prevalence in the background population. The disease has severe, negative effects on quality of life and sometimes on social status. Epidemiological studies have identified risk factors for onset and prognosis, but treatment of the disease is rarely evidence based, and a classification system for different subdiagnoses of hand eczema is not agreed upon. Randomized controlled trials investigating the treatment of hand eczema are called for. For this, as well as for clinical purposes, a generally accepted classification system for hand eczema is needed. The present study attempts to characterize subdiagnoses of hand eczema with respect to basic demographics, medical history and morphology. Clinical data from 416 patients with hand eczema from 10 European patch test clinics were assessed. A classification system for hand eczema is proposed. It is suggested that this classification be used in clinical work and in clinical trials.
  •  
3.
  • Ekqvist, Susanne, et al. (författare)
  • High frequency of contact allergy to gold in patients with endovascular coronary stents
  • 2007
  • Ingår i: British Journal of Dermatology. - : Oxford University Press (OUP). - 1365-2133 .- 0007-0963. ; 157:4, s. 730-738
  • Tidskriftsartikel (refereegranskat)abstract
    • Background Stent implantation is an effective method for treatment of atherosclerotic disease. Factors predisposing to in-stent restenosis are still largely unknown. Contact allergy to metal ions eluted from the stent has been suggested to be a risk factor. Objectives To explore whether there is a possible induction of contact allergy to metals used in stents among patients with a stainless steel stent containing nickel (Ni stent) and patients with a gold-plated stent (Au stent). Methods Adults (n = 484) treated with coronary stent implantation participated in the study with patch testing. The study design was retrospective and cross-sectional with no assessment of contact allergy before stenting. Age- and sex-matched patch-tested patients with dermatitis (n = 447) served as controls. Results Of Au-stented patients, 54 of 146 (37%) were allergic to gold compared with 85 of 447 (19%) controls (P < 0.001). Within the stented population there were no statistically significant differences in contact allergy to gold or nickel between Ni-stented and Au-stented patients. In multivariate models where other risk factors for contact allergy to gold were considered, the Au stent showed a trend towards statistical significance (odds ratio 1.43, 95% confidence interval 0.95-2.16; P = 0.09). Conclusions As the frequency of contact allergy to gold is higher in stented patients independent of stent type it suggests a previous sensitization. However, several pieces of circumstantial evidence as well as statistical analysis indicate the possibility of sensitization in the coronary vessel by the Au stent. Ni stents and Au stents should not be ruled out as risk factors for induction of contact allergy to these metals.
  •  
4.
  •  
5.
  • Matura, M, et al. (författare)
  • Selected oxidized fragrance terpenes are common contact allergens
  • 2005
  • Ingår i: Contact Dermatitis. - : Wiley. - 0105-1873 .- 1600-0536. ; 52:6, s. 320-328
  • Tidskriftsartikel (refereegranskat)abstract
    • Terpenes are widely used fragrance compounds in fine fragrances, but also in domestic and occupational products. Terpenes oxidize easily due to autoxidation on air exposure. Previous studies have shown that limonene, linalool and caryophyllene are not allergenic themselves but readily form allergenic products on air-exposure. This study aimed to determine the frequency and characteristics of allergic reactions to selected oxidized fragrance terpenes other than limonene. In total 1511 consecutive dermatitis patients in 6 European dermatology centres were patch tested with oxidized fragrance terpenes and some oxidation fractions and compounds. Oxidized linalool and its hydroperoxide fraction were found to be common contact allergens. Of the patients tested, 1.3% showed a positive reaction to oxidized linalool and 1.1% to the hydroperoxide fraction. About 0.5% of the patients reacted to oxidized caryophyllene whereas 1 patient reacted to oxidized myrcene. Of the patients reacting to the oxidized terpenes, 58% had fragrance-related contact allergy and/or a positive history for adverse reaction to fragrances. Autoxidation of fragrance terpenes contributes greatly to fragrance allergy, which emphasizes the need of testing with compounds that patients are actually exposed to and not only with the ingredients originally applied in commercial formulations.
  •  
6.
  • Thyssen, Jacob Pontoppidan, et al. (författare)
  • p-Phenylenediamine sensitization is more prevalent in central and southern European patch test centres than in Scandinavian: results from a multicentre study
  • 2009
  • Ingår i: Contact Dermatitis. - : Wiley. - 0105-1873 .- 1600-0536. ; 60:6, s. 314-319
  • Tidskriftsartikel (refereegranskat)abstract
    • Positive patch test reactions to p-phenylenediamine (PPD) are common. PPD is used in oxidative hair dyes and is also present in dark henna temporary 'tattoos'. Cross-sensitization to other contact allergens may occur. Because subjects sensitized to PPD are at risk of clinically severe reactions upon hair dyeing, there is a need for 'current' prevalence data on PPD sensitization. To compare PPD patch test results from dermatitis patients tested between 2003 and 2007 in 10 European patch test centres and to analyse the causes and determine relevance of positive PPD patch test reactions. Patch testing was performed using PPD (1% free base in petrolatum from Trolab (Almirall Hermal GmbH, Reinbeck, Germany) or Chemotechnique (Malmo, Sweden), equivalent to 0.090 mg/cm(2) in the TRUE (R) test from MEKOS Laboratories AS). Statistical analysis was performed using the chi-squared test. The weighted average prevalence was 4.6% among 21 515 patients. PPD sensitization occurred more often in centres located in Central and Southern Europe than in Scandinavian centres (odds ratio = 2.40; 95% confidence interval = 2.07-2.78). The overall proportion of positive patch test reactions to PPD that were registered as being of either current or 'past' relevance was high (weighted average 53.6% and 20.3%, respectively). Consumer hair dyeing was the most prominent cause of PPD sensitization (weighted average 41.8%). Furthermore, occupational hair dye exposure (10.6%) and cross-sensitization to textile dyes (12.6%) were frequently reported. PPD sensitization caused by exposure to hair dyes is frequent and remains a present problem for patients visiting contact dermatitis clinics, especially in patch test centres located in Central and Southern Europe.
  •  
7.
  • Agner, Tove, et al. (författare)
  • Contact sensitisation in hand eczema patients-relation to subdiagnosis, severity and quality of life: a multi-centre study
  • 2009
  • Ingår i: Contact Dermatitis. - 0105-1873. ; 61:5, s. 291-296
  • Tidskriftsartikel (refereegranskat)abstract
    • Background Contact sensitisation has been identified as a factor associated with poor prognosis for patients with hand eczema. Objectives To study implications of contact sensitisation with respect to severity, quality of life (QoL) and subdiagnosis of hand eczema. Methods The study was performed as a multi-centre, cross-sectional study from 10 European clinics. All patients were patch tested, and severity of hand eczema assessed by Hand Eczema Severity Index. A multi-variate analysis was performed to explore which factors influenced severity, QoL and sick leave. Results A total 416 patients were included, and 63% had contact sensitisation to one or more of the tested allergens. More women (66%) than men (51%) were sensitized. No significant association was found between sensitisation to specific allergens, disease severity, QoL or diagnostic subgroups. High age, male sex, atopic eczema and presence of contact sensitisation were independent risk factors for increased severity as measured by Hand Eczema Severity Index. Furthermore, the severity of hand eczema increased by the number of contact sensitisations detected (P = 0.023). High age and personal history of atopic eczema were independent risk factors for low QoL, as measured by Dermatology Life Quality Index, and atopic eczema as well as allergic contact dermatitis as subdiagnosis was associated with increased sick leave. Conclusion Diagnostic subgroups were not found to be related to specific allergens. Contact sensitisation was found to be a risk factor for increased severity of hand eczema, as did high age, male sex and atopic eczema.
  •  
8.
  • Agner, Tove, et al. (författare)
  • Hand eczema severity and quality of life: a cross-sectional, multicentre study of hand eczema patients
  • 2008
  • Ingår i: Contact Dermatitis. - : Wiley. - 0105-1873 .- 1600-0536. ; 59:1, s. 43-47
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and Objectives: Hand eczema is a chronic disease with negative impact on quality of life (QoL). In this study, QoL in hand eczema patients is assessed and related to age, sex, severity, and diagnostic subgroups. Methods: A total of 416 patients with hand eczema from 10 European patch test clinics participated in the study. Data on QoL were obtained from a self-administered questionnaire using the Dermatology Life Quality Index (DLQI). Severity was assessed by a scoring system (Hand Eczema Severity Index, HECSI) as well as frequency of eruptions and sick leave due to hand eczema. Results: No significant difference was found between males and females with respect to QoL [DLQI median values and 25/75 percentiles for males and females being 7.0 (3-14) and 8.0 (3-13), respectively], although males were more severely affected than females (P < 0.025). A significant positive correlation was found for hand eczema severity and age (P < 0.001), while no significant correlation was found for QoL and age. QoL was found increasingly reduced when sick leave was getting higher (P < 0.001). A statistically significant correlation between QoL (as measured by DLQI) and hand eczema severity as measured by HECSI was found (P < 0.001). No significant difference in QoL was found between diagnostic subgroups. Conclusions: QoL was found markedly negatively affected in hand eczema patients and was significantly correlated to disease severity. No significant difference in QoL was found between males and females, in spite of significantly more severe eczema in males, indicating that QoL in female patients is more easily affected.
  •  
9.
  •  
10.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 19

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy