1. |
- Hau-Riege, S. P., et al.
(författare)
-
Force Field Benchmark of Organic Liquids : Density, Enthalpy of Vaporization, Heat Capacities, Surface Tension, Isothermal Compressibility, Volumetric Expansion Coefficient, and Dielectric Constant
- 2007
-
Ingår i: Physical Review Letters. - 0031-9007 .- 1079-7114. ; 98:14, s. 145502-
-
Tidskriftsartikel (refereegranskat)abstract
- At the recently built FLASH x-ray free-electron laser, we studied the reflectivity of Si/C multilayers with fluxes up to 3×1014W/cm2. Even though the nanostructures were ultimately completely destroyed, we found that they maintained their integrity and reflectance characteristics during the 25-fs-long pulse, with no evidence for any structural changes over lengths greater than 3Å. This experiment demonstrates that with intense ultrafast pulses, structural damage does not occur during the pulse, giving credence to the concept of diffraction imaging of single macromolecules.
|
|
2. |
|
|
3. |
|
|
4. |
- Chalupsky, J, et al.
(författare)
-
Non-thermal desorption/ablation of molecular solids induced by ultra-short soft x-ray pulses
- 2009
-
Ingår i: Optics Express. - 1094-4087. ; 17:1, s. 208-217
-
Tidskriftsartikel (refereegranskat)abstract
- We report the first observation of single-shot soft x-ray laser induced desorption occurring below the ablation threshold in a thin layer of poly ( methyl methacrylate) - PMMA. Irradiated by the focused beam from the Free-electron LASer in Hamburg ( FLASH) at 21.7nm, the samples have been investigated by atomic-force microscope (AFM) enabling the visualization of mild surface modifications caused by the desorption. A model describing non-thermal desorption and ablation has been developed and used to analyze single-shot imprints in PMMA. An intermediate regime of materials removal has been found, confirming model predictions. We also report below-threshold multiple-shot desorption of PMMA induced by high-order harmonics (HOH) at 32nm. Short-time exposure imprints provide sufficient information about transverse beam profile in HOH's tight focus whereas long-time exposed PMMA exhibits radiation-initiated surface hardening making the beam profile measurement infeasible. (C) 2008 Optical Society of America
|
|
5. |
|
|
6. |
- Khanna, Chand, et al.
(författare)
-
The dog as a cancer model
- 2006
-
Ingår i: Nature Biotechnology. - : Springer Science and Business Media LLC. - 1087-0156 .- 1546-1696. ; 24:9, s. 1065-1066
-
Tidskriftsartikel (refereegranskat)
|
|