SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Ventura F.) srt2:(2005-2009)"

Search: WFRF:(Ventura F.) > (2005-2009)

  • Result 1-8 of 8
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Schael, S, et al. (author)
  • Precision electroweak measurements on the Z resonance
  • 2006
  • In: Physics Reports. - : Elsevier BV. - 0370-1573 .- 1873-6270. ; 427:5-6, s. 257-454
  • Research review (peer-reviewed)abstract
    • We report on the final electroweak measurements performed with data taken at the Z resonance by the experiments operating at the electron-positron colliders SLC and LEP. The data consist of 17 million Z decays accumulated by the ALEPH, DELPHI, L3 and OPAL experiments at LEP, and 600 thousand Z decays by the SLID experiment using a polarised beam at SLC. The measurements include cross-sections, forward-backward asymmetries and polarised asymmetries. The mass and width of the Z boson, m(Z) and Gamma(Z), and its couplings to fermions, for example the p parameter and the effective electroweak mixing angle for leptons, are precisely measured: m(Z) = 91.1875 +/- 0.0021 GeV, Gamma(Z) = 2.4952 +/- 0.0023 GeV, rho(l) = 1.0050 +/- 0.0010, sin(2)theta(eff)(lept) = 0.23153 +/- 0.00016. The number of light neutrino species is determined to be 2.9840 +/- 0.0082, in agreement with the three observed generations of fundamental fermions. The results are compared to the predictions of the Standard Model (SM). At the Z-pole, electroweak radiative corrections beyond the running of the QED and QCD coupling constants are observed with a significance of five standard deviations, and in agreement with the Standard Model. Of the many Z-pole measurements, the forward-backward asymmetry in b-quark production shows the largest difference with respect to its SM expectation, at the level of 2.8 standard deviations. Through radiative corrections evaluated in the framework of the Standard Model, the Z-pole data are also used to predict the mass of the top quark, m(t) = 173(+10)(+13) GeV, and the mass of the W boson, m(W) = 80.363 +/- 0.032 GeV. These indirect constraints are compared to the direct measurements, providing a stringent test of the SM. Using in addition the direct measurements of m(t) and m(W), the mass of the as yet unobserved SM Higgs boson is predicted with a relative uncertainty of about 50% and found to be less than 285 GeV at 95% confidence level. (c) 2006 Elsevier B.V. All rights reserved.
  •  
2.
  • Abbondanno, U, et al. (author)
  • The data acquisition system of the neutron time-of-flight facility n_TOF at CERN
  • 2005
  • In: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 538:1-3, s. 692-702
  • Journal article (peer-reviewed)abstract
    • The n_TOF facility at CERN has been designed for the measurement of neutron capture, fission and (n, xn) cross-sections with high accuracy. This requires a flexible and-due to the high instantaneous neutron flux-almost dead time free data acquisition system. A scalable and versatile data solution has been designed based on 8-bit flash-ADCs with sampling rates up to 2 GHz and 8 Mbyte memory buffer. The software is written in C and C++ and is running on PCs equipped with RedHat Linux.
  •  
3.
  •  
4.
  • Baroni, M. P. M. A., et al. (author)
  • Optical and morphological properties of porous diamond-like-carbon films deposited by magnetron sputtering
  • 2006
  • In: Journal of Non-Crystalline Solids. - : Elsevier BV. - 0022-3093 .- 1873-4812. ; 352:32-35, s. 3734-3738
  • Journal article (peer-reviewed)abstract
    • Porous diamond-like-carbon (PDLC) thin films obtained on silicon substrate by DC low energy magnetron sputtering have been investigated by photoluminescence, transmission and reflection spectroscopy, photoacoustic and spectroscopic ellipsometry. The absorption features observed for these films show similarities with those of porous silicon (PS) as well as in the performed gradient structural pattern classification of the SFM porosity, by means of the computational GPA-flyby environment on PS and PDLC samples. The dielectric function is also calculated for the bulk diamond-like carbon using the full-potential linearized augmented plane wave method within the framework of local density approximation to density functional theory. From the measurement a low real dielectric constant of about 4.5 at 0.8 eV was found whereas the calculated e(1)(0) for the bulk diamond has a value of 5.5.
  •  
5.
  •  
6.
  •  
7.
  • Peskov, V., et al. (author)
  • Development and first tests of GEM-Like detectors with resistive electrodes
  • 2007
  • In: IEEE Transactions on Nuclear Science. - : Institute of Electrical and Electronics Engineers (IEEE). - 0018-9499 .- 1558-1578. ; 54:5, s. 1784-1791
  • Journal article (peer-reviewed)abstract
    • We have developed and tested several prototypes of GEM-like detectors with electrodes coated with resistive layers or completely made of resistive materials. These detectors can operate stably at gains close to 10(5). The resistive layers limit the energy of discharges appearing at higher gains thus making the detectors very robust. We demonstrated that the cathodes of some of these detectors could be coated by CsI or SbCs layers to enhance the detection efficiency for the UV and visible photons. We also discovered that such detectors can operate stably in the cascade mode and high overall gains (similar to 10(6)) are reachable. Applications in several areas, for example in RICH or in noble liquid TPCs are therefore possible. The first results from the detection of UV photons at room and cryogenic temperatures will be given.
  •  
8.
  • Ponsot, Elodie, 1973-, et al. (author)
  • Mitochondrial tissue specificity of substrates utilization in rat cardiac and skeletal muscles
  • 2005
  • In: Journal of Cellular Physiology. - Hoboken, USA : John Wiley & Sons. - 0021-9541 .- 1097-4652. ; 203:3, s. 479-86
  • Journal article (peer-reviewed)abstract
    • As energetic metabolism is crucial for muscles, they develop different adaptations to respond to fluctuating demand among muscle types. Whereas quantitative characteristics are known, no study described simultaneously quantitative and qualitative differences among muscle types in terms of substrates utilization patterns. This study thus defined the pattern of substrates preferential utilization by mitochondria from glycolytic gastrocnemius (GAS) and oxidative soleus (SOL) skeletal muscles and from heart left ventrical (LV) in rats. We measured in situ, ADP (2 mM)-stimulated, mitochondrial respiration rates from skinned fibers in presence of increasing concentrations of pyruvate (Pyr) + malate (Mal), palmitoyl-carnitine (Palm-C) + Mal, glutamate (Glut) + Mal, glycerol-3-phosphate (G3-P), lactate (Lact) + Mal. Because the fibers oxygen uptake (Vs) followed Michaelis-Menten kinetics in function of substrates level we determined the Vs and Km, representing maximal oxidative capacity and the mitochondrial sensibility for each substrate, respectively. Vs were in the order GAS < SOL < LV for Pyr, Glu, and Palm-C substrates, whereas in the order SOL = LV < GAS with G3-P. Moreover, the relative capacity to oxidize Palm-C is extremely higher in LV than in SOL. Vs was not stimulated by the Lact substrate. The Km was equal for Pyr among muscles, but much lower for G3-P in GAS and lower for Palm-C in LV. These results demonstrate qualitative mitochondrial tissue specificity for metabolic pathways. Mitochondria of glycolytic muscle fibers are well adapted to play a central role for maintaining a satisfactory cytosolic redox state in these fibers, whereas mitochondria of LV developed important capacities to use fatty acids.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-8 of 8

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view