SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Wennerberg Ann 1955 ) ;lar1:(gu);mspu:(article);srt2:(2015-2018);srt2:(2018)"

Sökning: WFRF:(Wennerberg Ann 1955 ) > Göteborgs universitet > Tidskriftsartikel > (2015-2018) > (2018)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Johansson, Pär, et al. (författare)
  • Biomechanical, histological, and computed X-ray tomographic analyses of hydroxyapatite coated PEEK implants in an extended healing model in rabbit
  • 2018
  • Ingår i: Journal of Biomedical Materials Research Part A. - : Wiley. - 1549-3296 .- 1552-4965. ; 106:5, s. 1440-1447
  • Tidskriftsartikel (refereegranskat)abstract
    • A nanosized hydroxyapatite (HA) modification on polyetheretherketone (PEEK) using a novel spin coating technique was investigated in a rabbit model. Spin coating technique creates a 20-40 nm thick layer of nanosized HA particles with similar shape, size, and crystallinity as human bone. Some implants were designed with a perforating hole in the apical region to mimic a fusion chamber of a spinal implant. The coating nano-structures were assessed using a scanning electron microscope. The in vivo response to HA-PEEK was compared to untreated PEEK with respect to removal torque, histomorphometry, and computed microtomography. The HA-coated and pure PEEK implants were inserted in the tibia and femur bone according to simple randomization. The rabbits were sacrificed 20 weeks after implantation. Removal torque analysis showed significantly higher values for HA-PEEK. Qualitative histological evaluation revealed an intimate contact between PEEK and the bone at the threads and perforated hole. Histomorphometric assessment showed higher bone-implant and bone area values for HA-PEEK but without statistical significance. The effect of the HA coating showed most prominent effect in the removal torque which may be correlated to an alteration in the bone quality around the HA-PEEK implants. (c) 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 106A: 1440-1447, 2018.
  •  
2.
  •  
3.
  • Trindade, Ricardo, et al. (författare)
  • Osseointegration and foreign body reaction: Titanium implants activate the immune system and suppress bone resorption during the first 4 weeks after implantation
  • 2018
  • Ingår i: Clinical Implant Dentistry and Related Research. - : Wiley. - 1523-0899 .- 1708-8208. ; 20:1, s. 82-91
  • Tidskriftsartikel (refereegranskat)abstract
    • © 2017 Wiley Periodicals, Inc. Background: Osseointegration mechanisms are still not entirely understood. Purpose: The present pilot study aims at demonstrating the involvement of the immune system in the process of osseointegration around titanium implants, comparing bone healing in the presence and absence of a titanium implant. Materials and Methods: Fifteen New Zealand White rabbits had one osteotomy performed at each of the distal femurs; on one side, no implant was placed (sham) and on the other side a titanium implant was introduced. Subjects were sacrificed at 10 and 28 days for gene expression analysis (three subjects each time point) and for decalcified qualitative histology (six subjects each time point). At 10 days, the three subjects for gene expression analysis were part of the six subjects for histology. Results: Gene expression analysis: at 10 days, ARG1 was significantly up-regulated around titanium, indicating an activation of M2-macrophages. At 28 days CD11b, ARG1, NCF-1, and C5aR1 were significantly up-regulated, indicating activation of the innate immune system, respectively M1-macrophages, M2-macrophages and group 2-innate lymphoid cells, neutrophils, and the complement system; on the other hand, the bone resorption markers RANKL, OPG, cathepsin K, and TRAP were significantly down-regulated around titanium. Histology: at 10 days new bone formation is seen around both sham and titanium sites, separating bone marrow from the osteotomy/implant site; at 28 days no bone trabeculae is seen on the sham site, which is healing at the original cortical level, whereas around titanium implants, bone continues into organization of more mature cortical-like bone, forming a layer between the implant and the bone marrow. Conclusions: The presence of a titanium implant during bone healing activates the immune system and displays type 2 inflammation, which is likely to guide the host-biomaterial relationship. At the same time, bone resorption is suppressed around titanium sites compared to sham sites after 4 weeks of implantation, suggesting a shift to a more pronounced bone forming environment. This suggests two important steps in osseointegration: identification of the titanium foreign body by the immune system and the development of a bone forming environment, that at tissue level translates into bone build-up on the titanium surface and can be perceived as an attempt to isolate the foreign body from the bone marrow space.
  •  
4.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy