SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "db:Swepub ;conttype:(refereed);spr:hun;pers:(Szentkiralyi István)"

Sökning: db:Swepub > Refereegranskat > Ungerska > Szentkiralyi István

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Szabó, Zoltán, et al. (författare)
  • Kiegészítő klinikai módszer a nyitott szívműtéteknél fellépő légembolisatio csökkentésére : [A complementary clinical method to minimize air embolism during open-heart surgery]
  • 2008
  • Ingår i: Magyar Sebeszet. - : Akademiai Kiado. - 0025-0295 .- 1789-4301. ; 61, s. 57-59
  • Tidskriftsartikel (refereegranskat)abstract
    • Air from the left heart is ejected even up to several hours after cardiopulmonary bypass (CPB) despite the use of CO 2 . The following method is complementary in addition to surgical de-airing in order to further reduce the chance of air embolism, especially from the pulmonary veins. After re-expanding the lungs with standard bag inflation, the ventilation is restarted in consultation with the surgeon. The ventilator is set to the respiratory minute volume used before the CPB but at a respiratory frequency of 10/minutes whereas the regularly beating heart is filled from the heart lung machine. Transoesophageal echocardiography (TEE) reliably controls the effect.
  •  
2.
  • Tamas, Eva, et al. (författare)
  • [Simple surgical method for intraoperative evaluation of adequacy of tricuspid annuloplasty].
  • 2008
  • Ingår i: Magyar sebészet. - 0025-0295. ; 61:1, s. 49-52
  • Tidskriftsartikel (refereegranskat)abstract
    • In tricuspid annuloplasty intraoperative "real time" evaluation using transoesophageal echocardiography requires normal flow to get reliable result. It means that the patient has to be already weaned from the cardiopulmonary bypass by the time of evaluation. In the authors' experience a well functioning tricuspid annuloplasty prevents back-flow through the valve. It can be observed on on-pump beating heart. If the tricuspid valve is competent, it is unnecessary to suck the blood flowing back through the coronary sinus while closing the right atrium. This observation seems to correlate well with post cardiopulmonary bypass transoesophageal echocardiography measurements and the control transthoracic echocardiography right before discharging the patients. These statements are based on a group of 72 patients. Sixty-nine patients (95.8%) were discharged (early mortality 4.2%). Only in one case we could observe a discrepancy between the intraoperative surgical observation and the postoperative echocardiographic finding. Development of functional tricuspid regurgitation in left-sided heart disease is a warning sign for myocardial impairment, which is an indication for surgery. Tricuspid annuloplasty can be performed even with moderate to medium grade regurgitation because it improves the early and late outcome. The described method is an adequate method for intraoperative evaluation of the repaired tricuspid valve competency.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2
Typ av publikation
tidskriftsartikel (2)
Typ av innehåll
Författare/redaktör
Tamas, Eva (2)
Maros, Tamás (2)
Hermansson, Ulf (1)
Szabó, Zoltan (1)
Träff, Stefan (1)
visa fler...
Peterffy, Arpad (1)
Galajda, Zoltán (1)
Palotás, Lehel (1)
Jagamos, Endre (1)
visa färre...
Lärosäte
Linköpings universitet (2)
Språk
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (1)
År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy