SwePub
Sök i SwePub databas

  Utökad sökning

AND är defaultoperator och kan utelämnas

Träfflista för sökning "hsv:(MEDICAL AND HEALTH SCIENCES) hsv:(Clinical Medicine) hsv:(Surgery) ;lar1:(kth)"

Sökning: hsv:(MEDICAL AND HEALTH SCIENCES) hsv:(Clinical Medicine) hsv:(Surgery) > Kungliga Tekniska Högskolan

  • Resultat 1-10 av 59
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Zeybel, M., et al. (författare)
  • Combined metabolic activators therapy ameliorates liver fat in nonalcoholic fatty liver disease patients
  • 2021
  • Ingår i: Molecular Systems Biology. - : EMBO. - 1744-4292. ; 17:10
  • Tidskriftsartikel (refereegranskat)abstract
    • Nonalcoholic fatty liver disease (NAFLD) refers to excess fat accumulation in the liver. In animal experiments and human kinetic study, we found that administration of combined metabolic activators (CMAs) promotes the oxidation of fat, attenuates the resulting oxidative stress, activates mitochondria, and eventually removes excess fat from the liver. Here, we tested the safety and efficacy of CMA in NAFLD patients in a placebo-controlled 10-week study. We found that CMA significantly decreased hepatic steatosis and levels of aspartate aminotransferase, alanine aminotransferase, uric acid, and creatinine, whereas found no differences on these variables in the placebo group after adjustment for weight loss. By integrating clinical data with plasma metabolomics and inflammatory proteomics as well as oral and gut metagenomic data, we revealed the underlying molecular mechanisms associated with the reduced hepatic fat and inflammation in NAFLD patients and identified the key players involved in the host-microbiome interactions. In conclusion, we showed that CMA can be used to develop a pharmacological treatment strategy in NAFLD patients.
  •  
2.
  •  
3.
  • Olivecrona, Henrik, et al. (författare)
  • A new computed tomography-based radiographic method to detect early loosening of total wrist implants
  • 2007
  • Ingår i: Acta Radiologica. - London, UK : Informa Healthcare. - 0284-1851 .- 1600-0455. ; 48:9, s. 997-1003
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Diagnosis of loosening of total wrist implants is usually late using routine radiographs. Switching modality to computed tomography (CT) should aid in early diagnosis. Purpose: To propose and evaluate the accuracy of a new CT method for assessing loosening of the carpal component in total wrist arthroplasty. Material and Methods: A protocol encompassing volume registration of paired CT scans of patients with unexplained pain in a prosthetically replaced wrist (used in clinical routine) is presented. Scans are acquired as a dynamic examination under torsional load. Using volume registration, the carpal component of the prosthesis is brought into spatial alignment. After registration, prosthetic loosening is diagnosed by a shift in position of the bones relative to the prosthesis. This study is a preclinical validation of this method using a human cadaverous arm with a cemented total wrist implant and tantalum markers. Seven CT scans of the arm were acquired. The scans were combined into 21 pairs of CT volumes. The carpal component was registered in each scan pair, and the residual mismatch of the surrounding tantalum markers and bone was analyzed both visually and numerically. Results: The detection limit for prosthetic movement was less than 1 mm. Conclusion: The results of this study demonstrate that CT volume registration holds promise to improve detection of movement of the carpal component at an earlier stage than is obtainable with plain radiography.
  •  
4.
  • Altay, Özlem, et al. (författare)
  • Combined Metabolic Activators Accelerates Recovery in Mild-to-Moderate COVID-19
  • 2021
  • Ingår i: Advanced Science. - : Wiley. - 2198-3844. ; 8:17
  • Tidskriftsartikel (refereegranskat)abstract
    • COVID-19 is associated with mitochondrial dysfunction and metabolic abnormalities, including the deficiencies in nicotinamide adenine dinucleotide (NAD+) and glutathione metabolism. Here it is investigated if administration of a mixture of combined metabolic activators (CMAs) consisting of glutathione and NAD+ precursors can restore metabolic function and thus aid the recovery of COVID-19 patients. CMAs include l-serine, N-acetyl-l-cysteine, nicotinamide riboside, and l-carnitine tartrate, salt form of l-carnitine. Placebo-controlled, open-label phase 2 study and double-blinded phase 3 clinical trials are conducted to investigate the time of symptom-free recovery on ambulatory patients using CMAs. The results of both studies show that the time to complete recovery is significantly shorter in the CMA group (6.6 vs 9.3 d) in phase 2 and (5.7 vs 9.2 d) in phase 3 trials compared to placebo group. A comprehensive analysis of the plasma metabolome and proteome reveals major metabolic changes. Plasma levels of proteins and metabolites associated with inflammation and antioxidant metabolism are significantly improved in patients treated with CMAs as compared to placebo. The results show that treating patients infected with COVID-19 with CMAs lead to a more rapid symptom-free recovery, suggesting a role for such a therapeutic regime in the treatment of infections leading to respiratory problems.
  •  
5.
  • Chireh, A., et al. (författare)
  • Safety evaluation of high-risk myocardial micro-biopsy in a swine model
  • 2022
  • Ingår i: Heart and Vessels. - : Springer Nature. - 0910-8327 .- 1615-2573. ; 37:4, s. 697-704
  • Tidskriftsartikel (refereegranskat)abstract
    • The objective of the study was to investigate the safety profile of high-risk micro-endomyocardial biopsy (micro-EMB) compared to conventional EMB in a large animal model. Twenty pigs were subjected to a maximum of 30 consecutive biopsies, including sampling from the free ventricular wall, with either micro-EMB (n = 10) or conventional EMB (n = 10). There were no major complications in the micro-EMB group (0/10), compared to six major complications in the EMB group (6/10; p = 0.003). Survival analysis further highlighted these differences (p = 0.004). There were significantly higher volumes of pericardial effusion in the EMB group (p = 0.01). The study shows a safety advantage of micro-EMB compared to standard EMB in the experimental high-risk circumstances investigated in this animal study. These results indicate enhanced possibilities to collect samples from sensitive areas by using the micro-EMB technique instead of standard EMB. 
  •  
6.
  • Eriksson, Jesper, et al. (författare)
  • Temporal patterns of organ dysfunction after severe trauma
  • 2021
  • Ingår i: Critical Care. - : Springer Nature. - 1364-8535 .- 1466-609X. ; 25:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Background Understanding temporal patterns of organ dysfunction (OD) may aid early recognition of complications after trauma and assist timing and modality of treatment strategies. Our aim was to analyse and characterise temporal patterns of OD in intensive care unit-admitted trauma patients. Methods We used group-based trajectory modelling to identify temporal trajectories of OD after trauma. Modelling was based on the joint development of all six subdomains comprising the sequential organ failure assessment score measured daily during the first two weeks post trauma. Further, the time for trajectories to stabilise and transition to final group assignments were evaluated. Results Six-hundred and sixty patients were included in the final model. Median age was 40 years, and median ISS was 26 (IQR 17-38). We identified five distinct trajectories of OD. Group 1, mild OD (n = 300), median ISS of 20 (IQR 14-27), had an early resolution of OD and a low mortality. Group 2, moderate OD (n = 135), and group 3, severe OD (n = 87), were fairly similar in admission characteristics and initial OD but differed in subsequent OD trajectories, the latter experiencing an extended course and higher mortality. In group 3, 56% of the patients developed sepsis as compared with 19% in group 2. Group 4, extreme OD (n = 40), received most blood transfusions, had the highest proportion of shock at admission and a median ISS of 41 (IQR 29-50). They experienced significant and sustained OD affecting all organ systems and a 28-day mortality of 30%. Group 5, traumatic brain injury with OD (n = 98), had the highest mortality of 35% and the shortest time to death for non-survivors, median 3.5 (IQR 2.4-4.8) days. Groups 1 and 5 reached their final group assignment early, > 80% of the patients within 48 h. In contrast, groups 2 and 3 had a prolonged time to final group assignment. Conclusions We identified five distinct trajectories of OD after severe trauma during the first two weeks post-trauma. Our findings underline the heterogeneous course after trauma and describe some potentially important clinical insights that are suggested by the groupings and temporal trajectories.
  •  
7.
  • Martufi, Giampaolo, 1980-, et al. (författare)
  • Multidimensional growth measurements of abdominal aortic aneurysms
  • 2013
  • Ingår i: Journal of Vascular Surgery. - : Elsevier BV. - 0741-5214 .- 1097-6809. ; 58:3, s. 748-755
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Monitoring the expansion of abdominal aortic aneurysms (AAAs) is critical to avoid aneurysm rupture in surveillance programs, for instance. However, measuring the change of the maximum diameter over time can only provide limited information about AAA expansion. Specifically, regions of fast diameter growth may be missed, axial growth cannot be quantified, and shape changes of potential interest for decisions related to endovascular aneurysm repair cannot be captured. Methods: This study used multiple centerline-based diameter measurements between the renal arteries and the aortic bifurcation to quantify AAA growth in 51 patients from computed tomography angiography (CTA) data. Criteria for inclusion were at least 1 year of patient follow-up and the availability of at least two sufficiently high-resolution CTA scans that allowed an accurate three-dimensional reconstruction. Consequently, 124 CTA scans were systematically analyzed by using A4clinics diagnostic software (VASCOPS GmbH, Graz, Austria), and aneurysm growth was monitored at 100 cross-sections perpendicular to the centerline. Results: Monitoring diameter development over the entire aneurysm revealed the sites of the fastest diameter growth, quantified the axial growth, and showed the evolution of the neck morphology over time. Monitoring the development of an aneurysm's maximum diameter or its volume over time can assess the mean diameter growth (r = 0.69, r = 0.77) but not the maximum diameter growth (r = 0.43, r = 0.34). The diameter growth measured at the site of maximum expansion was similar to 16%/y, almost four times larger than the mean diameter expansion of 4.4%/y. The sites at which the maximum diameter growth was recorded did not coincide with the position of the maximum baseline diameter (rho = 0.12; P = .31). The overall aneurysm sac length increased from 84 to 89 mm during the follow-up (P < .001), which relates to the median longitudinal growth of 3.5%/y. The neck length shortened, on average, by 6.2% per year and was accompanied by a slight increase in neck angulation. Conclusions: Neither maximum diameter nor volume measurements over time are able to measure the fastest diameter growth of the aneurysm sac. Consequently, expansion-related wall weakening might be inappropriately reflected by this type of surveillance data. In contrast, localized spots of fast diameter growth can be detected through multiple centerline-based diameter measurements over the entire aneurysm sac. This information might further reinforce the quality of aneurysm surveillance programs.
  •  
8.
  • Jedenmalm, Anneli, et al. (författare)
  • Validation of a 3D CT method for measurement of linear wear of acetabular cups : A hip simulator study
  • 2011
  • Ingår i: Acta Orthopaedica. - : Medical Journals Sweden AB. - 1745-3674 .- 1745-3682. ; 82:1, s. 35-41
  • Tidskriftsartikel (refereegranskat)abstract
    • Material and methods Ultra-high molecular weight polyethylene cups with a titanium mesh molded on the outside were subjected to wear using a hip simulator. Before and after wear, they were (1) imaged with a CT scanner using a phantom model device, (2) measured using a coordinate measurement machine (CMM), and (3) weighed. CMM was used as the reference method for measurement of femoral head penetration into the cup and for comparison with CT, and gravimetric measurements were used as a reference for both CT and CMM. Femoral head penetration and wear vector angle were studied. The head diameters were also measured with both CMM and CT. The repeatability of the method proposed was evaluated with two repeated measurements using different positions of the phantom in the CT scanner. Results The accuracy of the 3D CT method for evaluation of linear wear was 0.51 mm and the repeatability was 0.39 mm. Repeatability for wear vector angle was 17 degrees A degrees. Interpretation This study of metal-meshed hip-simulated acetabular cups shows that CT has the capacity for reliable measurement of linear wear of acetabular cups at a clinically relevant level of accuracy.
  •  
9.
  • Johansson, Björn, et al. (författare)
  • Visual and optical performance of the Akreos Adapt Advanced Optics and Tecnis Z9000 intraocular lenses. Swedish multicenter study
  • 2007
  • Ingår i: Journal of cataract and refractive surgery. - : Ovid Technologies (Wolters Kluwer Health). - 0886-3350 .- 1873-4502. ; 33:9, s. 1565-1572
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: To compare the subjective visual and objective optical performance of 2 aspherical intraocular lenses (lOLs), the Akreos Adapt Advanced Optics (AO) (Bausch & Lomb, Inc.) and the Tecnis Z9000 (Advanced Medical Optics, Inc.). SETTING: Four university hospitals in Sweden. METHODS: This study comprised 80 patients, 20 each from 4 university hospital centers in Sweden. All patients had bilateral clear corneal phacoemulsification with implantation of an Akreos Adapt AO IOL in 1 eye and Tecnis Z9000 IOL in the other eye according to a randomization protocol. Preoperatively, 90% contrast Early Treatment Diabetic Retinopathy Study (ETDRS) visual acuity was measured and the mesopic pupil sizes were determined. Ten to 12 weeks postoperatively, 12.5% and 90% contrast ETDRS visual acuities and photopic and mesopic Functional Acuity Contrast Test chart contrast sensitivities were determined. Wavefront analysis was performed with the Zywave II aberrometer (Bausch & Lomb, Inc.), and a questionnaire on the subjective quality of vision was completed by each patient. RESULTS: The Akreos AO IOL and Tecnis Z9000 IOL produced similar high- and low-contrast visual acuities as well as photopic and mesopic contrast sensitivities. The Tecnis Z9000 IOL resulted in lower spherical aberrations of the eye (mean 0.05 ± 0.13 μm versus 0.35 ± 0.13 μm root mean square, 6.0 mm pupil) (P<.001); however, the Akreos AO IOL provided a larger depth of field (mean 1.22 diopter [D] ± 0.48 [SD] versus 0.86 ± 0.50 D, 6.0 mm pupil) (P<.001). Patient satisfaction was generally high, although 68.8% of the patients reported some type of visual disturbance postoperatively. Twenty-eight percent of patients reported better subjective visual quality in the Akreos AO eye and 14%, in the Tecnis Z9000 eye (P<.0001). Accordingly, 33% perceived more visual disturbances in the Tecnis Z9000 eye and 11%, in the Akreos AO eye (P<.0001). CONCLUSIONS: Maximum reduction of spherical aberration did not maximize subjective visual quality. The higher perceived quality of vision with the Akreos AO IOL could be because of differences in depth of field, lOL material, or IOL design.
  •  
10.
  • Otten, Volker, et al. (författare)
  • Are CT Scans a Satisfactory Substitute for the Follow-Up of RSA Migration Studies of Uncemented Cups? : A Comparison of RSA Double Examinations and CT Datasets of 46 Total Hip Arthroplasties
  • 2017
  • Ingår i: BioMed Research International. - : Hindawi Publishing Corporation. - 2314-6133 .- 2314-6141. ; 2017
  • Tidskriftsartikel (refereegranskat)abstract
    • As part of the 14-year follow-up of a prospectively randomized radiostereometry (RSA) study on uncemented cup fixation, two pairs of stereo radiographs and a CT scan of 46 hips were compared. Tantalum beads, inserted during the primary operation, were detected in the CT volume and the stereo radiographs and used to produce datasets of 3D coordinates. The limit of agreement between the combined CT and RSA datasets was calculated in the same way as the precision of the double RSA examination. The precision of RSA corresponding to the 99% confidence interval was 1.36 degrees, 1.36 degrees, and 0.60 degrees for X-, Y-, and Z-rotation and 0.40, 0.17, and 0.37mm for X-, Y-, and Z-translation. The limit of agreement between CT and RSA was 1.51 degrees, 2.17 degrees, and 1.05 degrees for rotation and 0.59, 0.56, and 0.74mm for translation. The differences between CT and RSA are close to the described normal 99% confidence interval for precision in RSA: 0.3 degrees to 2 degrees for rotation and 0.15 to 0.6mm for translation. We conclude that measurements using CT and RSA are comparable and that CT can be used for migration studies for longitudinal evaluations of patients with RSA markers.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 59
Typ av publikation
tidskriftsartikel (56)
annan publikation (1)
konferensbidrag (1)
forskningsöversikt (1)
Typ av innehåll
refereegranskat (53)
övrigt vetenskapligt/konstnärligt (6)
Författare/redaktör
Uhlén, Mathias (7)
Maguire Jr., Gerald ... (5)
Gasser, T. Christian (5)
Noz, Marilyn E. (5)
Olivecrona, Henrik (5)
Lundberg, J. (3)
visa fler...
Jonsson, Stefan (3)
Holmin, S. (3)
Gutmark, Ephraim (3)
Zeleznik, Michael P. (3)
Mihaescu, Mihai, 197 ... (3)
Pontén, Fredrik (2)
Mardinoglu, Adil (2)
Nielsen, Jens B, 196 ... (2)
Arif, Muhammad (2)
Schwenk, Jochen M. (2)
Meijer, Sebastiaan, ... (2)
Borén, Jan, 1963 (2)
Mardinoglu, Adil, 19 ... (2)
Jedenmalm, Anneli (2)
Magnusson, Kristina (2)
Jirström, Karin (2)
Agustsson, T (2)
Enochsson, Lars (2)
Eriksson, Per (2)
Sandell, Mikael (2)
Roy, Joy (2)
Altay, Özlem (2)
Li, Xiangyu (2)
Yang, Hong (2)
Kim, Woonghee (2)
Turkez, H. (2)
Aminoff, Hedvig (2)
Arnelo, Urban (2)
Groth, Kristina (2)
Romero, Mario, 1973- (2)
Brennan, Donal J (2)
El-Hajj, Victor Gabr ... (2)
Buwaider, Ali (2)
Edström, Erik, 1975- (2)
Elmi-Terander, Adria ... (2)
Iop, Alessandro (2)
Parker, Louis P. (2)
Doyle, Barry J. (2)
Kiessling, Jonas (2)
Fedeli, Stefano (2)
Sakalihasan, Natzi (2)
Norman, Paul E (2)
Mylavarapu, Goutham (2)
Laczik, Tamas (2)
visa färre...
Lärosäte
Karolinska Institutet (30)
Uppsala universitet (9)
Göteborgs universitet (6)
Umeå universitet (6)
Lunds universitet (4)
visa fler...
Chalmers tekniska högskola (4)
Linköpings universitet (3)
Örebro universitet (2)
Mittuniversitetet (2)
Stockholms universitet (1)
Malmö universitet (1)
RISE (1)
Sophiahemmet Högskola (1)
Röda Korsets Högskola (1)
visa färre...
Språk
Engelska (59)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (59)
Teknik (11)
Naturvetenskap (2)
Samhällsvetenskap (1)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy