SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "hsv:(MEDICIN OCH HÄLSOVETENSKAP) hsv:(Klinisk medicin) ;srt2:(1990-1999);pers:(Valentin Lil)"

Sökning: hsv:(MEDICIN OCH HÄLSOVETENSKAP) hsv:(Klinisk medicin) > (1990-1999) > Valentin Lil

  • Resultat 1-10 av 27
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Flygare, Annika, et al. (författare)
  • Ultrasound measurements of subcutaneous adipose tissue in infants are reproducible
  • 1999
  • Ingår i: Journal of Pediatric Gastroenterology and Nutrition - Jpgn. - 1536-4801. ; 28:5, s. 492-494
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: The purpose of this study was to evaluate the ultrasound technique for measuring subcutaneous adipose tissue in infants. METHODS: Twenty infants were investigated at 3, 6, and 12 months of age. All measurements were made by the same investigator in triplicate on the left side of the body at the triceps and subscapular anatomic landmarks and at the abdomen and thigh. An ultrasound system equipped with a linear 7.0-MHz transducer was used. RESULTS: The intraclass correlation coefficients were 0.88 to 0.99. Random errors ranged from 0.01 to 0.19 mm. For log-transformed values, the random error ranged from 2.4% to 5.7%. CONCLUSIONS: Measurements of subcutaneous fat in infants using ultrasound are reproducible when performed by the same observer.
  •  
2.
  • Gudmundsson, Saemundur, et al. (författare)
  • Factors affecting color Doppler energy ultrasound recordings in an in-vitro model
  • 1998
  • Ingår i: Ultrasound in Medicine and Biology. - 0301-5629. ; 24:6, s. 899-902
  • Tidskriftsartikel (refereegranskat)abstract
    • Compared to conventional color Doppler ultrasound imaging, the new color Doppler modality "color Doppler energy" (CDE) has improved the possibility of visualizing blood vessels having low blood-flow velocities, but appears to be influenced by the settings of the ultrasound instrument and motion artefacts. The aim of this methodological study was to evaluate the effects of the different factors on the CDE signal. The CDE mode of a commercially available ultrasound system (Acuson 128 XP) was tested in an in vitro study. The effect of depth, angle of insonation, flow velocity, instrument power output, gain and other instrument settings were evaluated. The CDE signals obtained were stored on videotape and subsequently subjected to off-line computer analysis. The CDE signal intensity was found to be influenced mainly by fluid flow velocity, but was also affected by depth and instrument settings. Gain and power had, however, limited influence in this setting. Thus, the intensity of the CDE signal is influenced by several factors. Our results emphasize the need for optimum fixed preinstalled instrument settings when attempting to quantify organ perfusion by use of this new technique.
  •  
3.
  • Jorgensen, F S, et al. (författare)
  • MULTISCAN--a Scandinavian multicenter second trimester obstetric ultrasound and serum screening study
  • 1999
  • Ingår i: Acta Obstetricia et Gynecologica Scandinavica. - 1600-0412. ; 78:6, s. 501-510
  • Tidskriftsartikel (refereegranskat)abstract
    • AIM: To study the detection rates of second trimester ultrasound screening for neural tube defects (NTD), abdominal wall defects (AWD) and Down's syndrome (DS) in low risk populations at tertiary centers, and to compare the ultrasound screening detection rates with those that were obtainable by biochemical serum screening (double test: alpha-fetoprotein/human chorion gonadotrophin/age test). STUDY DESIGN: Prospective multicenter study with a three year inclusion period: 1/1/1989-31/12/1991. SUBJECTS: 27,844 low-risk women at 18-34 years of age who had a second trimester ultrasound screening examination. Of these, 10,264 also had a serum test. METHODS: An ultrasound malformation scan and a serum test were carried out at 17-19 weeks of gestation. Risk calculations regarding DS were based on alpha-fetoprotein, human chorion gonadotrophin and maternal age; performed retrospectively for the first two years. RESULTS: In total 73 cases were identified in the study population: NTD (n=34), AWD (n=7) and DS (n=32). The detection rates, (%, with 95% confidence interval) for ultrasound screening were: NTD: 79.4 (62.1-91.3); AWD: 85.7 (42.1-99.6); DS: 6.3 (0.8-20.8). In the subgroup of women who had both tests, the detection rates for ultrasound screening vs double test were: NTD: 62.5 (24.5-91.5) vs 75.0 (34.9-96.8); AWD: 66.7 (9.4-99.2) vs 100 (29.2-100.0); DS: 7.7 (0.2-36.0) vs 46.2 (19.2-74.9). The false positive rates (%) for ultrasound screening vs double test were: NTD: 0.01/3.3; AWD: 0.01/3.3; DS: 0.1/4.0. CONCLUSION: Second trimester ultrasound screening in a low risk population gave a low detection rate for fetal DS (6.3%) and an acceptable detection rate for NTD (79.4%) and AWD (85.7%). In the subgroup of women who had both tests, serum screening performed better than ultrasound as applied in the present study, especially regarding DS.
  •  
4.
  • Karlsson, Bengt, et al. (författare)
  • Transvaginal ultrasonography of the endometrium in women with postmenopausal bleeding--a Nordic multicenter study
  • 1995
  • Ingår i: American Journal of Obstetrics and Gynecology. - : Elsevier BV. - 1097-6868 .- 0002-9378. ; 172:5, s. 1488-1494
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE: The purpose of this study was to use transvaginal ultrasonographic measurements to find the thickness of the endometrium below which the risk of endometrial abnormality in women with postmenopausal bleeding is low. STUDY DESIGN: This multicenter study was carried out at eight clinics in four Nordic countries. The study included 1168 women with postmenopausal bleeding scheduled for curettage Before the curettage was performed, the thickness of the endometrium was measured with transvaginal ultrasonography. The measurement included both endometrial layers (double-layer technique). The transvaginal ultrasonographic measurement was compared with the histopathologic diagnosis of the curettage specimens. RESULTS: In women with atrophic endometrium the mean endometrial thickness (+/- SD) was 3.9 +/- 2.5 mm. The corresponding figures for women with endometrial cancer were 21.1 +/- 11.8 mm. No malignant endometrium was thinner than 5 mm. In 30 women (2.8%) it was not possible to measure the thickness of the endometrium; one of these women had endometrial cancer. The 95% confidence limit for the probability of excluding endometrial abnormality was 5.5% when the endometrial thickness was < or = 4 mm as measured by transvaginal ultrasonography. CONCLUSION: The risk of finding pathologic endometrium at curettage when the endometrium is < or = 4 mm as measured by transvaginal ultrasonography is 5.5%. Thus in women with postmenopausal bleeding and an endometrium < or = 4 mm it would seem justified to refrain from curettage.
  •  
5.
  • Maesel, A, et al. (författare)
  • Fetal cerebral blood flow velocity during labor and the early neonatal period
  • 1994
  • Ingår i: Ultrasound in Obstetrics & Gynecology. - : Wiley. - 1469-0705 .- 0960-7692. ; 4:5, s. 372-376
  • Tidskriftsartikel (refereegranskat)abstract
    • This study was performed to elucidate circulatory changes in the fetal cerebral circulation during uncomplicated labor and in early neonatal life. Eighteen healthy term singleton fetuses were followed longitudinally during labor. Using the transabdominal approach, and the color Doppler technique, the middle cerebral artery was identified and Doppler flow velocity waveforms recorded between and during uterine contractions. Neonatal recordings were made by insonating the middle cerebral artery from the temporal region before and immediately after the cutting of the umbilical cord, and at 1 hour and 1 day after birth. The recorded Doppler signals were evaluated for pulsatility index, heart rate, peak systolic flow velocity, end-diastolic flow velocity and time-averaged maximum velocity. There was no change in the pulsatility index between and during contractions (1.39 +/- 0.36 and 1.40 +/- 0.39, respectively, mean +/- SD). A significant decrease in the pulsatility index compared to fetal values was seen 4 min after birth (1.06 +/- 0.30, p < 0.01). One hour after birth, the pulsatility index values increased significantly (1.52 +/- 0.25, p < 0.001), to fall again between I hour and 1 day after birth (0.95 +/- 0.26, p < 0.001). Mechanical compression of the skull, blood gas changes and a decrease in ductal shunting may all have contributed to these changes. The present study has shown physiological neonatal circulatory adaptation and onset of breathing to cause manifest changes in cerebral blood flow velocity.
  •  
6.
  • Sjöström, Karin, et al. (författare)
  • Do pre-, early, and mid-pregnancy life events influence gestational length?
  • 1999
  • Ingår i: Journal of Psychosomatic Obstetrics and Gynecology. - 0167-482X. ; 20:3, s. 170-176
  • Tidskriftsartikel (refereegranskat)abstract
    • The aim of this study was to determine whether the frequency and quality of reported life events during the 6 months before pregnancy to mid-pregnancy influence gestational age at birth. Seventy nulliparous women were studied at 12 and 25 gestational weeks with a 64-item self-rated life event questionnaire developed for obstetric groups. Life events were categorised into eight psychosocial areas according to the diagnostic and statistic manual (DSM-III-R). The women rated each experienced event as strainful or not strainful. Gestational age was determined by ultrasound biometry before 20 gestational weeks. The number of life events during the following periods was recorded from 6 months before pregnancy to 12 gestational weeks, from 12 gestational weeks to 25 gestational weeks, from 6 months before pregnancy to 25 gestational weeks. No significant relationships were found between the number of reported life events and pregnancy duration. Life events in different psychosocial areas also did not influence gestational age at birth. A non-significant relationship (p = 0.06) was found between pregnancy duration and the number of strainful events reported from 6 months before pregnancy to 25 gestational weeks, shorter pregnancy duration being found in women reporting many strainful events. Our findings suggest that life events in general do not influence pregnancy duration. However, if they are perceived as strainful, pregnancy length tends to decrease.
  •  
7.
  • Sjöström, Karin, et al. (författare)
  • Maternal anxiety in late pregnancy and fetal hemodynamics
  • 1997
  • Ingår i: European Journal of Obstetrics, Gynecology, and Reproductive Biology. - 0301-2115. ; 74:2, s. 149-155
  • Tidskriftsartikel (refereegranskat)abstract
    • The aim of this study was to investigate if fetal circulation is affected by maternal anxiety. 37 nulliparous women were studied prospectively in the third trimester of pregnancy, with self-rate tests of anxiety (STAI). Doppler ultrasound examination of the umbilical artery and fetal middle cerebral artery was performed at 37-40 gestational weeks. The pulsatility index (PI) was calculated and corrected for heart rate. The women were divided into groups of increasing levels of anxiety. The fetuses of women with high trait anxiety scores had significantly higher PI values in the umbilical artery (p = 0.0056), significantly lower PI values in the fetal middle cerebral artery (p = 0.0029) and significantly lower cerebro-umbilical PI ratios (p = 0.0002), suggesting a change in blood distribution in favor of brain circulation in the fetuses. Maternal weight, weight-increase, height, age, marital status, smoking habits, drinking habits and socio-economic factors known to affect fetal well-being did not interfere with these findings. No significant differences in birth-weight, length and head circumference were found between infants born to mothers with higher trait anxiety levels compared to mothers with lower trait anxiety levels. Our results suggest that maternal stress, in terms of trait anxiety, influences fetal cerebral circulation.
  •  
8.
  • Sladkevicius, Povilas, et al. (författare)
  • Blood flow velocity in the uterine and ovarian arteries during menstruation
  • 1994
  • Ingår i: Ultrasound in Obstetrics & Gynecology. - : Wiley. - 1469-0705 .- 0960-7692. ; 4:5, s. 421-427
  • Tidskriftsartikel (refereegranskat)abstract
    • Eleven healthy women with regular menstrual cycles were examined with a combination of two-dimensional real-time ultrasound and color and spectral Doppler techniques on the 7th day after follicular rupture, and on the 1st, 2nd, 3rd and 4th days of menstrual bleeding. Both uterine arteries, arteries in the stroma and hila of both ovaries, in the wall of the largest follicle of the non-dominant ovary and in the wall of the corpus luteum were examined with the Doppler technique. The pulsatility index (PI) and the time-averaged maximum velocity were calculated. In the uterine arteries, the PI was highest on the first day of menstrual bleeding (median PI 3.2 for the dominant and 3.0 for the non-dominant uterine artery), after which it decreased to its lowest values on the second day (median PI 2.1 and 1.8, respectively) and third day (median PI 2.2 and 2.1, respectively). The time-averaged maximum velocity reached its highest value on the second and third days of menstruation. The corpus luteum was still visible on the first day of menstrual bleeding in all women, and on the second day in five. It was indistinguishable on the third and fourth days of menstruation in all women. In the dominant ovary, the time-averaged maximum velocity of flow in the arteries in the ovarian hilum decreased during menstrual bleeding and was lower during menstruation than in the preceding luteal phase. In the non-dominant ovary, neither the PI nor the time-averaged maximum velocity manifested any consistent changes during the period studied. We conclude that substantial changes in PI and time-averaged maximum velocity occur in the uterine arteries and in the arteries of the dominant ovary during menstruation.
  •  
9.
  • Sladkevicius, Povilas, et al. (författare)
  • Blood flow velocity in the uterine and ovarian arteries during the normal menstrual cycle
  • 1993
  • Ingår i: Ultrasound in Obstetrics & Gynecology. - : Wiley. - 1469-0705 .- 0960-7692. ; 3:3, s. 199-208
  • Tidskriftsartikel (refereegranskat)abstract
    • Twelve healthy women with regular menstrual cycles were examined with a combination of two-dimensional real-time ultrasound and color and spectral Doppler techniques on cycle days 4 and 8 and daily from cycle day 12 until follicular rupture, then days + 1, +2, +5, +7 and +12 after follicular rupture. The uterine and subendometrial arteries, arteries in the ovarian stroma and hilum, in the wall of the largest follicle of each ovary, and in the wall of the corpus luteum were examined. The pulsatility index and the time-averaged maximum velocity were calculated. In the uterine arteries the pulsatility index was highest on day + 2, after which it decreased successively to its lowest value, whereas the time-averaged maximum velocity reached its highest value on day + 12. Similar changes were observed in the subendometrial arteries. In the non-dominant ovary, neither the pulsatility index nor the time-averaged maximum velocity manifested any consistent changes during the cycle. In the dominant ovary, the time-averaged maximum velocity increased and the pulsatility index decreased after follicular rupture, being significantly higher and lower, respectively, in the luteal than in the follicular phase. These changes were seen in the ovarian hilum, stroma and follicular wall, but were most obvious in the wall of the dominant follicle and of the corpus luteum. We conclude that the blood circulation in the uterus and in the dominant ovary changes considerably during the menstrual cycle, whereas that in the non-dominant ovary shows no unequivocal changes.
  •  
10.
  • Sladkevicius, Povilas, et al. (författare)
  • Endometrial thickness and Doppler velocimetry of the uterine arteries as discriminators of endometrial status in women with postmenopausal bleeding: a comparative study
  • 1994
  • Ingår i: American Journal of Obstetrics and Gynecology. - 1097-6868. ; 171:3, s. 722-728
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE: Our purpose was to compare the ability of transvaginal Doppler ultrasonographic examination with that of gray-scale ultrasonographic examination to discriminate between benign and malignant and between normal and pathologic endometrium in women with postmenopausal bleeding. STUDY DESIGN: One hundred thirty-eight consecutive women scheduled for curettage because of postmenopausal bleeding underwent transvaginal ultrasonography, including color and spectral Doppler techniques, within 8 days preceding the operation. The thickness of the endometrium was measured. Doppler signals of the maximum blood flow velocity obtained from the two main uterine arteries and subendometrial and intraendometrial arteries were evaluated for pulsatility index and time-averaged maximum velocity. The results of the examinations were compared with the histologic diagnosis of the curettage specimen. RESULTS: Receiver-operator characteristic curves showed endometrial thickness to be a better discriminator between normal and pathologic and between benign and malignant endometrium than any Doppler variable, 14 mm being the optimal threshold value for differentiating between benign and malignant endometrium (sensitivity 88%, specificity 81%). CONCLUSION: Measurement of endometrial thickness with transvaginal ultrasonography is a better method for discriminating between benign and malignant or normal and pathologic endometrium than is Doppler velocimetry of the uterine arteries.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 27

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy