SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "hsv:(MEDICIN OCH HÄLSOVETENSKAP) hsv:(Klinisk medicin) ;srt2:(1990-1999);srt2:(1998);pers:(Steen Stig)"

Sökning: hsv:(MEDICIN OCH HÄLSOVETENSKAP) hsv:(Klinisk medicin) > (1990-1999) > (1998) > Steen Stig

  • Resultat 1-5 av 5
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Eriksson, Leif, et al. (författare)
  • Lung transplantation at the University of Lund 1990-1995. Analysis of the first 39 consecutive patients
  • 1998
  • Ingår i: Scandinavian Cardiovascular Journal. - : Informa UK Limited. - 1651-2006 .- 1401-7431. ; 32:1, s. 23-28
  • Tidskriftsartikel (refereegranskat)abstract
    • Between 1990 and 1995 39 patients were lung transplanted at the University Hospital in Lund. This is a retrospective review of survival and lung function in these patients. There were 17 single-lung transplants (SLT), 21 double-lung transplants (DLT) and 1 heart-lung transplant (HLT). Seven patients died during the period, giving an overall survival of 82%. One-year survival according to Kaplan-Meier survival analysis was 87%, and 2-year survival was 83%. Vital capacity and forced expiratory volume in 1 s (FEV1) 1 year after transplantation were 91% and 100% of predicted, respectively, in the DLT group and 60% and 50% in the SLT group. Bronchiolitis obliterans syndrome (BOS) developed in 11 of the 35 patients (31%) surviving more than 6 months, 2/21 in the DLT group and 8/13 in the SLT group and in the patient with HLT. The median time until detection of BOS was 11 months after the operation (range 6-18 months). Working capacity 1 year after transplantation was 60% of predicted in the DLT group and 47% of predicted in the SLT group. Ventilatory capacity was no longer function limiting. Lung transplantation today is a therapeutic option with a good medium-term survival and good functional results in selected patients with severe lung disease.
  •  
2.
  • Budrikis, A, et al. (författare)
  • Function of adult pig hearts after 2 and 12 hours of cold cardioplegic preservation
  • 1998
  • Ingår i: Annals of Thoracic Surgery. - 1552-6259. ; 66:1, s. 73-78
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Most cardioplegic solutions have been developed using the classic Langendorf heart perfusion model, which only allows a short experimental follow-up. Our aim was to investigate hearts after prolonged storage by using a physiologic model including prolonged perfusion with normal, fresh blood. METHODS: Sixteen hearts from 60-kg pigs were preserved with dextran-enriched (dextran-40, 35 g/L) St. Thomas' solution for 2 or 12 hours after which they were continuously reperfused for 12 hours with normal blood, supplied by a support pig. A flexible balloon, fixed to an artificial valve apparatus connected to a circuit system, was inserted in the left ventricle for obtaining measurements of hemodynamic performance. RESULTS: During the first 3 to 4 hours of reperfusion there was no significant difference in left ventricular developed pressure, cardiac output, minute work output, or oxygen consumption between the two groups. After this time left ventricular developed pressure (p < 0.001), cardiac output (p < 0.01), minute work output (p < 0.01), and oxygen consumption were significantly lower in the 12-hour group. Coronary flow was higher (p < 0.01) and coronary vascular resistance lower (p < 0.01) during the first 5 to 6 hours of reperfusion in the 12-hour group. After 12 hours of reperfusion coronary vascular resistance was significantly higher (p < 0.01) in the 12-hour group. CONCLUSIONS: High-degree and long-lasting coronary hyperemia at the beginning of reperfusion can be a sign of unsatisfactory preservation of the heart. This investigation shows the importance of reperfusion with normal blood and a long follow-up period after postischemic reperfusion when studying the effect of cardioplegic solutions.
  •  
3.
  • Eriksson, Leif, et al. (författare)
  • Induced hypothermia in critical respiratory failure after lung transplantation
  • 1998
  • Ingår i: Annals of Thoracic Surgery. - 1552-6259. ; 65:3, s. 827-829
  • Tidskriftsartikel (refereegranskat)abstract
    • Primary graft failure after lung transplantation is a serious complication with high mortality. We present 2 cases of critical respiratory failure after lung transplantation treated with surface cooling to 32 degrees and 35 degrees C, respectively, as an adjunct to conventional intensive care. Both patients were discharged from the hospital in good clinical condition. Surface cooling may be an effective mode of treatment in patients with critical respiratory failure after lung transplantation and should be considered before extracorporeal membrane oxygenation treatment is initiated.
  •  
4.
  • Koul, Bansi, et al. (författare)
  • HeartMate left ventricular assist device as bridge to heart transplantation
  • 1998
  • Ingår i: Annals of Thoracic Surgery. - 1552-6259. ; 65:6, s. 1625-1630
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Because of the limited supply of donor hearts, prospective recipients continue to die while on the waiting list for heart transplantation. Use of long-term mechanical circulatory support devices as a bridge to transplantation may reduce this mortality. However, with the present state of technology, continued clinical evaluation of the various long-term, mechanical circulatory support devices available is mandatory. METHODS: Sixteen patients were bridged with the HeartMate left ventricular assist device (LVAD) to heart transplantation for New York Heart Association functional class IV cardiac failure. Twelve pneumatic and six electric devices were used. The mean cardiac index and the mean pulmonary vascular resistance of the patient cohort were 1.71 x min(-1) x m(-2) and 3.1 Wood units, respectively. RESULTS: The mean LVAD support time per transplanted patient was 237 days, with a cumulative LVAD support time of about 7.2 years. Bleeding was the main operative and postoperative complication. Two patients suffered from neurologic complications and there were two major incidents of device malfunction. Twelve patients (75%) now have received a transplant, 3 (19%) are awaiting a transplant, and in 1 patient (6%), the device was explanted after spontaneous left ventricular recovery. Eleven of the 12 patients who received a transplant are alive and doing well. The HeartMate LVAD gave adequate circulatory support over extended periods of time and reversed the vital organ dysfunction. Since the start of the LVAD program, only 1 patient has died on our heart transplantation waiting list, compared to nine deaths in the 2 preceding years. CONCLUSIONS: The HeartMate LVAD bridge to heart transplantation can be performed with low post-LVAD implantation and posttransplantation mortality and offers 1- and 2-year posttransplantation actuarial survival rates comparable to those for nonbridged heart transplant recipients.
  •  
5.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-5 av 5

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy