SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "hsv:(MEDICIN OCH HÄLSOVETENSKAP) hsv:(Klinisk medicin) ;srt2:(2010-2019);hsvcat:2"

Sökning: hsv:(MEDICIN OCH HÄLSOVETENSKAP) hsv:(Klinisk medicin) > (2010-2019) > Teknik

  • Resultat 1-10 av 795
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Abtahi, Jahan, et al. (författare)
  • Bisphosphonate coating might improve fixation of dental implants in the maxilla: A pilot study
  • 2010
  • Ingår i: International Journal of Oral and Maxillofacial Surgery. - : Elsevier Science B.V., Amsterdam. - 0901-5027 .- 1399-0020. ; 39:7, s. 673-677
  • Tidskriftsartikel (refereegranskat)abstract
    • This pilot study evaluates the clinical stability of bisphosphonate-coated dental implants placed using a two-stage surgical procedure in five patients. Each patient received seven regular Brånemark implants, one of which was coated with bisphosphonate in a fibrinogen matrix. The coated implant was inserted where the bone was expected to have the least favourable quality. The level of the marginal bone around each implant was measured by intraoral periapical radiographs and implant stability was recorded using resonance frequency measurements. Frequency values (ISQ) were obtained peroperatively before flap closure and after 6 months at abutment connection. At abutment connection the bisphosphonate-coated implants were removed en bloc in two patients for histological examination. An animal experiment had previously confirmed that gamma-sterilization did not reduce bioactivity of the bisphosphonate coating. In each patient, the bisphosphonate-coated implant showed the largest improvement in ISQ level of all implants. Their values at the start tended to be lower, and the absolute value at 6 months did not differ. No complications occurred with the coated implants. Histology showed no abnormalities. Improvement in ISQ values was an expected effect of the bisphosphonate coating, but could be due to the choice of insertion site. This finding warrants a randomized, blinded study.
  •  
2.
  • Alt Murphy, Margit, 1970, et al. (författare)
  • An upper body garment with integrated sensors for people with neurological disorders – early development and evaluation
  • 2019
  • Ingår i: BMC Biomedical Engineering. - : Springer Science and Business Media LLC. - 2524-4426. ; 1:3
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: To develop a novel wearable garment with integrated sensors for continuous monitoring of physiological and movement related variables to evaluate progression, tailor treatments and improve diagnosis in epilepsy, Parkinson’s disease and stroke. Methods: An iterative development process and evaluation of an upper body garment with integrated sensors included: identification of user needs, specification of technical and garment requirements, garment development and production as well as evaluation of garment design, functionality and usability. The project is a multidisciplinary collaboration with experts from medical, engineering, textile, and material science within the wearITmed consortium. The work was organized in regular meetings, task groups and hands-on workshops. User needs were identified using results from a mixed-methods systematic review, a focus group study and expert groups. Usability was evaluated in 19 individuals (13 controls, 6 patients with Parkinson’s disease) using semi-structured interviews and qualitative content analysis. Results: A prototype designed to monitor movements and heart rate was developed. The garment was well accepted by the users regarding design and comfort, although the users were cautious about the technology and suggested improvements. All electronic components passed a washability test. The most robust data was obtained from accelerometer and gyroscope sensors while the electrodes for heart rate registration were sensitive to motion. artefacts. The algorithm development within the wearITmed consortium has shown promising results. Conclusions: The prototype was accepted by the users. Technical improvements are needed, but preliminary data indicate that the garment has potential to be used as a tool for diagnosis and treatment selection and could provide added value for monitoring seizures in epilepsy, fluctuations in PD and activity levels in stroke. Future work aims to improve the prototype further, develop algorithms, and evaluate the functionality and usability in targeted patient groups. The potential of incorporating blood pressure and heart-rate variability monitoring will also be explored.
  •  
3.
  • Johansson, Björn (författare)
  • Opacification of anterior part of hydrophilic acrylic IOL or a prelenticular inflammatory membrane?
  • 2012
  • Ingår i: Journal of cataract and refractive surgery. - Philadelphia : Elsevier. - 0886-3350 .- 1873-4502. ; 38:6, s. 1115-1116
  • Tidskriftsartikel (refereegranskat)abstract
    • In their recent case report, Park and Chuck1 describe the bilateral appearance of an opacification at the plane of the anterior surface of the hydrophilic acrylic Akreos MI60 intraocular lens (IOL) (Bausch & Lomb). The patient's general history of diabetes mellitus, proliferative retinopathy, and iris rubeosis explains the limited pupil dilation preventing visualization of the capsulorhexis opening in their slitlamp images.
  •  
4.
  •  
5.
  • Inci, Kamuran, et al. (författare)
  • Air bubbles are released by thoracic endograft deployment: An in vitro experimental study
  • 2016
  • Ingår i: SAGE Open Medicine. - : SAGE Publications. - 2050-3121. ; 4
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: Embolic stroke is a dreaded complication of thoracic endovascular aortic repair. The prevailing theory about its cause is that particulate debris from atherosclerotic lesions in the aortic wall are dislodged by endovascular instruments and embolize to the brain. An alternative source of embolism might be air trapped in the endograft delivery system. The aim of this experimental study was to determine whether air is released during deployment of a thoracic endograft. Methods: In an experimental benchtop study, eight thoracic endografts (five Medtronic Valiant Thoracic and three Gore TAG) were deployed in a water-filled transparent container drained from air. Endografts were prepared and deployed according to their instructions for use. Deployment was filmed and the volume of air released was collected and measured in a calibrated syringe. Results: Air was released from all the endografts examined. Air volumes ranged from 0.1 to 0.3 mL for Medtronic Valiant Thoracic and from <0.025 to 0.04 mL for Gore TAG. The largest bubbles had a diameter of approximately 3 mm and came from the proximal end of the Medtronic Valiant device. Conclusion: Air bubbles are released from thoracic endografts during deployment. Air embolism may be an alternative cause of stroke during thoracic endovascular aortic repair.
  •  
6.
  • Lundh, Torbjörn, 1965, et al. (författare)
  • Torque Devices
  • 2018
  • Annan publikation (övrigt vetenskapligt/konstnärligt)abstract
    • Torque devices for navigating a guidewire through a body lumen are disclosed. The devices have a variable speed transmission design, including at least a first transmission region along a first position of the device, and a second transmission region along a second position of the device. The first and second transmission regions have different diameters, thereby allowing rotational control of the guidewire between at least two different stroke angles.
  •  
7.
  • Ahlander, Britt-Marie, 1954-, et al. (författare)
  • An echo-planar imaging sequence is superior to a steady-state free precession sequence for visual as well as quantitative assessment of cardiac magnetic resonance stress perfusion
  • 2017
  • Ingår i: Clinical Physiology and Functional Imaging. - : Blackwell Publishing. - 1475-0961 .- 1475-097X. ; 37:1, s. 52-61
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: To assess myocardial perfusion, steady-state free precession cardiac magnetic resonance (SSFP, CMR) was compared with gradient-echo-echo-planar imaging (GRE-EPI) using myocardial perfusion scintigraphy (MPS) as reference.METHODS: Cardiac magnetic resonance perfusion was recorded in 30 patients with SSFP and in another 30 patients with GRE-EPI. Timing and extent of inflow delay to the myocardium was visually assessed. Signal-to-noise (SNR) and contrast-to-noise (CNR) ratios were calculated. Myocardial scar was visualized with a phase-sensitive inversion recovery sequence (PSIR). All scar positive segments were considered pathologic. In MPS, stress and rest images were used as in clinical reporting. The CMR contrast wash-in slope was calculated and compared with the stress score from the MPS examination. CMR scar, CMR perfusion and MPS were assessed separately by one expert for each method who was blinded to other aspects of the study.RESULTS: Visual assessment of CMR had a sensitivity for the detection of an abnormal MPS at 78% (SSFP) versus 91% (GRE-EPI) and a specificity of 58% (SSFP) versus 84% (GRE-EPI). Kappa statistics for SSFP and MPS was 0·29, for GRE-EPI and MPS 0·72. The ANOVA of CMR perfusion slopes for all segments versus MPS score (four levels based on MPS) had correlation r = 0·64 (SSFP) and r = 0·96 (GRE-EPI). SNR was for normal segments 35·63 ± 11·80 (SSFP) and 17·98 ± 8·31 (GRE-EPI), while CNR was 28·79 ± 10·43 (SSFP) and 13·06 ± 7·61 (GRE-EPI).CONCLUSION: GRE-EPI displayed higher agreement with the MPS results than SSFP despite significantly lower signal intensity, SNR and CNR.
  •  
8.
  • Forberg, Jakob L, et al. (författare)
  • An artificial neural network to safely reduce the number of ambulance ECGs transmitted for physician assessment in a system with prehospital detection of ST elevation myocardial infarction
  • 2012
  • Ingår i: Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine. - : Springer Science and Business Media LLC. - 1757-7241. ; 20:1, s. 1-9
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Pre-hospital electrocardiogram (ECG) transmission to an expert for interpretation and triage reduces time to acute percutaneous coronary intervention (PCI) in patients with ST elevation Myocardial Infarction (STEMI). In order to detect all STEMI patients, the ECG should be transmitted in all cases of suspected acute cardiac ischemia. The aim of this study was to examine the ability of an artificial neural network (ANN) to safely reduce the number of ECGs transmitted by identifying patients without STEMI and patients not needing acute PCI. Methods: Five hundred and sixty ambulance ECGs transmitted to the coronary care unit (CCU) in routine care were prospectively collected. The ECG interpretation by the ANN was compared with the diagnosis (STEMI or not) and the need for an acute PCI (or not) as determined from the Swedish coronary angiography and angioplasty register. The CCU physician's real time ECG interpretation (STEMI or not) and triage decision (acute PCI or not) were registered for comparison. Results: The ANN sensitivity, specificity, positive and negative predictive values for STEMI was 95%, 68%, 18% and 99%, respectively, and for a need of acute PCI it was 97%, 68%, 17% and 100%. The area under the ANN's receiver operating characteristics curve for STEMI detection was 0.93 (95% CI 0.89-0.96) and for predicting the need of acute PCI 0.94 (95% CI 0.90-0.97). If ECGs where the ANN did not identify a STEMI or a need of acute PCI were theoretically to be withheld from transmission, the number of ECGs sent to the CCU could have been reduced by 64% without missing any case with STEMI or a need of immediate PCI. Conclusions: Our ANN had an excellent ability to predict STEMI and the need of acute PCI in ambulance ECGs, and has a potential to safely reduce the number of ECG transmitted to the CCU by almost two thirds.
  •  
9.
  • Ahlander, Britt-Marie, 1954- (författare)
  • Magnetic Resonance Imaging of the Heart : Image quality, measurement accuracy and patient experience
  • 2016
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Background: Non-invasive diagnostic imaging of atherosclerotic coronary artery disease (CAD) is frequently carried out with cardiovascular magnetic resonance imaging (CMR) or myocardial perfusion single photon emission computed tomography (MPS). CMR is the gold standard for the evaluation of scar after myocardial infarction and MPS the clinical gold standard for ischemia. Magnetic Resonance Imaging (MRI) is at times difficult for patients and may induce anxiety while patient experience of MPS is largely unknown.Aims: To evaluate image quality in CMR with respect to the sequences employed, the influence of atrial fibrillation, myocardial perfusion and the impact of patient information. Further, to study patient experience in relation to MRI with the goal of improving the care of these patients.Method: Four study designs have been used. In paper I, experimental cross-over, paper (II) experimental controlled clinical trial, paper (III) psychometric crosssectional study and paper (IV) prospective intervention study. A total of 475 patients ≥ 18 years with primarily cardiac problems (I-IV) except for those referred for MRI of the spine (III) were included in the four studies.Result: In patients (n=20) with atrial fibrillation, a single shot steady state free precession (SS-SSFP) sequence showed significantly better image quality than the standard segmented inversion recovery fast gradient echo (IR-FGRE) sequence (I). In first-pass perfusion imaging the gradient echo-echo planar imaging sequence (GREEPI) (n=30) had lower signal-to-noise and contrast–to-noise ratios than the steady state free precession sequence (SSFP) (n=30) but displayed a higher correlation with the MPS results, evaluated both qualitatively and quantitatively (II). The MRIAnxiety Questionnaire (MRI-AQ) was validated on patients, referred for MRI of either the spine (n=193) or the heart (n=54). The final instrument had 15 items divided in two factors regarding Anxiety and Relaxation. The instrument was found to have satisfactory psychometric properties (III). Patients who prior CMR viewed an information video scored significantly (lower) better in the factor Relaxation, than those who received standard information. Patients who underwent MPS scored lower on both factors, Anxiety and Relaxation. The extra video information had no effect on CMR image quality (IV).Conclusion: Single shot imaging in atrial fibrillation produced images with less artefact than a segmented sequence. In first-pass perfusion imaging, the sequence GRE-EPI was superior to SSFP. A questionnaire depicting anxiety during MRI showed that video information prior to imaging helped patients relax but did not result in an improvement in image quality.
  •  
10.
  • Sant'Anna, Anita, 1983-, et al. (författare)
  • Assessment of Gait Symmetry and Gait Normality Using Inertial Sensors : In-Lab and In-Situ Evaluation
  • 2013
  • Ingår i: Biomedical Engineering Systems and Technologies. - Heidelberg : Springer Berlin/Heidelberg. - 9783642382550 - 9783642382567 ; 357, s. 239-254
  • Bokkapitel (refereegranskat)abstract
    • Quantitative gait analysis is a powerful tool for the assessment of a number of physical and cognitive conditions. Unfortunately, the costs involved in providing in-lab 3D kinematic analysis to all patients is prohibitive. Inertial sensors such as accelerometers and gyroscopes may complement in-lab analysis by providing cheaper gait analysis systems that can be deployed anywhere. The present study investigates the use of inertial sensors to quantify gait symmetry and gait normality. The system was evaluated in-lab, against 3D kinematic measurements; and also in-situ, against clinical assessments of hip-replacement patients. Results show that the system not only correlates well with kinematic measurements but it also corroborates various quantitative and qualitative measures of recovery and health status of hip-replacement patients
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 795
Typ av publikation
tidskriftsartikel (562)
konferensbidrag (160)
doktorsavhandling (26)
forskningsöversikt (15)
bokkapitel (11)
patent (9)
visa fler...
rapport (4)
annan publikation (4)
licentiatavhandling (3)
konstnärligt arbete (1)
bok (1)
visa färre...
Typ av innehåll
refereegranskat (675)
övrigt vetenskapligt/konstnärligt (120)
Författare/redaktör
Borga, Magnus (45)
Romu, Thobias (32)
Dahlqvist Leinhard, ... (27)
Nyholm, Dag (19)
Dahlqvist Leinhard, ... (16)
Wójcik, Andrzej (15)
visa fler...
Enqvist, Olof, 1981 (15)
Trägårdh, Elin (14)
Palmquist, Anders, 1 ... (14)
Ulén, Johannes (11)
Oestreicher, Ursula (11)
Wennerberg, Ann (11)
Smedby, Örjan (10)
Karlsson, Anette (10)
Engqvist, Håkan (10)
Edenbrandt, Lars, 19 ... (10)
Thomsen, Peter, 1953 (10)
Höglund, Odd (10)
Memedi, Mevludin, 19 ... (10)
Sommer, Sylwester (10)
Johansson, Carina B. ... (10)
Ortiz Catalan, Max J ... (9)
Jimbo, Ryo (9)
Westin, Jerker (9)
Gutmark, Ephraim (9)
Vral, Anne (9)
Andersson, Martin, 1 ... (9)
Bergquist, Filip, 19 ... (8)
Gregoire, Eric (8)
Moquet, Jayne (8)
Terzoudi, Georgia (8)
Hadjidekova, Valeria (8)
Andersson, Gerhard (8)
Smedby, Örjan, 1956- (7)
Uhlén, Mathias (7)
Tolmachev, Vladimir (7)
Sintorn, Ida-Maria (7)
Adolfsson, Erik (7)
Persson, Anders (7)
Nilsson, Markus (7)
Isaksson, Hanna (7)
Jirström, Karin (7)
Cinthio, Magnus (7)
Lundh, Torbjörn, 196 ... (7)
Beinke, Christina (7)
Trompier, Francois (7)
Gil, Octavia Monteir ... (7)
Ricoul, Michelle (7)
Sabatier, Laure (7)
Sebastia, Natividad (7)
visa färre...
Lärosäte
Chalmers tekniska högskola (194)
Göteborgs universitet (177)
Linköpings universitet (170)
Lunds universitet (137)
Uppsala universitet (134)
Karolinska Institutet (116)
visa fler...
Kungliga Tekniska Högskolan (111)
Umeå universitet (65)
Örebro universitet (48)
Stockholms universitet (44)
Malmö universitet (27)
RISE (23)
Sveriges Lantbruksuniversitet (21)
Luleå tekniska universitet (20)
Högskolan Dalarna (20)
Jönköping University (14)
Högskolan i Halmstad (12)
Linnéuniversitetet (10)
Högskolan i Borås (10)
Mittuniversitetet (8)
Högskolan i Skövde (5)
Blekinge Tekniska Högskola (5)
VTI - Statens väg- och transportforskningsinstitut (4)
Högskolan i Gävle (2)
Högskolan Väst (2)
Mälardalens universitet (2)
Gymnastik- och idrottshögskolan (2)
Södertörns högskola (1)
Karlstads universitet (1)
visa färre...
Språk
Engelska (789)
Svenska (6)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (795)
Naturvetenskap (142)
Samhällsvetenskap (33)
Humaniora (6)
Lantbruksvetenskap (2)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy