SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "hsv:(MEDICIN OCH HÄLSOVETENSKAP) hsv:(Klinisk medicin) srt2:(1990-1999);pers:(Strand Sven Erik)"

Sökning: hsv:(MEDICIN OCH HÄLSOVETENSKAP) hsv:(Klinisk medicin) > (1990-1999) > Strand Sven Erik

  • Resultat 1-10 av 38
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Sjöholm, H, et al. (författare)
  • Necrosis of malignant gliomas after intratumoral injection of 201Tl in vivo in the rat
  • 1995
  • Ingår i: Anti-Cancer Drugs. - 0959-4973. ; 6:1, s. 109-114
  • Tidskriftsartikel (refereegranskat)abstract
    • Fourteen adult Fischer 344 rats were inoculated in vivo unilaterally in the caudate nucleus in the brain with malignant RG 2 glioma cells. By 3 weeks a tumor with a diameter of 3-6 mm normally develops. Ten animals which survived the repeated periods of anesthesia and thallium (Tl) injections (intratumorally three times of 201Tl, 15-23 days after inoculation) showed a prolonged retention of radioactivity at the site of injection with no uptake in other organs except for the kidneys. Singular circumscribed necroses were found post-mortem at the site of injection, comprising malignant glioma tumor tissue, which in six animals was absent, in three animals was markedly reduced in size compared with controls and in one animal had the expected size. In four animals metastases were found in distant locations in the brain; in three of these cases there was a retention of radioactivity in the tumor. The selective necrotizing effect on the tumor cells is interpreted as mainly due to emission of Auger electrons from intracellularly accumulated 201Tl, giving rise to very high energy deposition in the vicinity of the cell nucleus. The results should also have implications for the treatment of human malignant gliomas.
  •  
2.
  •  
3.
  • Almquist, Helén, et al. (författare)
  • Quantitative SPECT by attenuation correction of the projection set using transmission data: evaluation of a method
  • 1990
  • Ingår i: European Journal Of Nuclear Medicine. - 1432-105X. ; 16:8-10, s. 587-594
  • Tidskriftsartikel (refereegranskat)abstract
    • A method for measuring attenuation coefficients in single-photon emission tomography (SPECT) is described and evaluated, together with a method for attenuation correction using these measured attenuation coefficients. Build-up, caused by scattered photons, is corrected for by a simple substitution in the algorithms. Transmission studies are performed with a 99mTc- or 57Co flood source, and emission phantom studies with 99mTc line sources. The method is evaluated with variable but well-defined phantoms. The result is accurate attenuation coefficients for different densities, dimensions and geometries, and an accuracy of corrected emission activities of better than +/- 10% in most cases. The present limitations of the method for attenuation correction are discussed.
  •  
4.
  • Brun, Eva, et al. (författare)
  • Early prediction of treatment outcome in head and neck cancer with 2-18FDG PET
  • 1997
  • Ingår i: Acta Oncologica. - : Informa UK Limited. - 1651-226X .- 0284-186X. ; 36:7, s. 741-747
  • Tidskriftsartikel (refereegranskat)abstract
    • The development of alternative treatment regimens in clinical oncology has increased the need for early prediction of cancer therapy outcome. The aim of this study was, early in the treatment phase, to identify patients with advanced head and neck cancer, responding or not responding to initiated therapy. The tumour metabolic rate of glucose (MRgl) examined by 2-18FDG-PET was determined in 17 patients before and after the first weeks of either radiotherapy (16-35 Gy) or one course of combination chemotherapy. Metabolic values uptake values normalized to plasma activity integrals--were correlated to loco-regional outcome, as evaluated 5-6 weeks after completion of treatment. Initial low tumour MRgl (<20 micromol/min/100 g tissue), in primary lesions or regional metastases, predicted a local complete response. When a high initial tumour MRgl was found, the magnitude of the reduction of MRgl in the second PET examination might be an adjunct in predicting local tumour response.
  •  
5.
  • Ceberg, Crister, et al. (författare)
  • A new method for quantification of image distortion due to pile-up in scintillation cameras
  • 1991
  • Ingår i: European Journal Of Nuclear Medicine. - 1432-105X. ; 18:12, s. 959-963
  • Tidskriftsartikel (refereegranskat)abstract
    • Characterization of the count-rate performance of scintillation cameras should include not only the specification of count losses. At high count rates, there is also an image distortion due to the mispositioning of pile-up events. In this paper a simple and clinically relevant procedure to quantify this distortion is presented. The images of a square uniform technetium-99m phantom at high and low count rates are used. The fraction of the total counts being correctly positioned is determined as the peripheral count density divided by the total average count density. This ratio, corrected for the camera non-uniformity at low count rates, is called the 'positioning ability'. According to the National Electrical Manufacturers' Association (NEMA), the 'system count rate performance with scatter' should be reported as the measured count rate giving 20% count losses. In this paper it is suggested that this measure be complemented by a measure of the fraction correct positioned events at this count rate. This fraction, the 'high count rate positioning ability', can be easily and accurately measured using our method. The method has been tested on two different scintillation cameras. For one of them the high count rate positioning ability was determined as 91% at a measured count rate of 30,000 s-1 with 20% count losses. For the other camera, the corresponding figures were 88% at 59,000 s-1 and close to 100% at 38,000 s-1, before and after the installation of a new pile-up rejection circuit, respectively.
  •  
6.
  •  
7.
  • Garkavij, Michael, et al. (författare)
  • Enhanced radioimmunotargeting of 125I-labeled L6-biotin monoclonal antibody (MAb) by combining preload of cold L6 MAb and subsequent immunoadsorption in rats
  • 1995
  • Ingår i: Cancer Research. - 1538-7445. ; 55:23 Suppl, s. 5874-5880
  • Tidskriftsartikel (refereegranskat)abstract
    • The present study investigates whether tumor:normal tissue uptake ratios of radiolabeled monoclonal antibodies can be further improved by a combination of extracorporeal immunoadsorption (ECIA) and preload with unlabeled idiotypic monoclonal antibody. Athymic rats, heterotransplanted with human lung carcinoma under the kidney capsule (SR tumor) and i.m. (IM tumor), were divided into four study groups: controls, ECIA, preload, and combined preload+ECIA. The preload+ECIA procedure reduced the whole-body and plasma activity by 48 and 89%, respectively. After such combined procedure, the uptake of 125I-labeled L6-biotin in SR tumors was unchanged, while the uptake in normal tissues was considerably reduced. Tumor (T):bone marrow ratio was then increased by 17.5 times (after ECIA) and by 4.5 times (24 h after ECIA). Similar enhancements were achieved for T:liver and T:kidney ratios. For the IM tumors, the ratios were not as high as for SR tumors. The effects on T:normal ratios of preload+ECIA in combination were synergistic. The combined procedure resulted both in an increased uptake and prolonged persistence of 125I-labeled L6-biotin in the SR tumors and also in a reduction of corresponding uptake values in organs critical for radiation.
  •  
8.
  • Garkavij, Michael, et al. (författare)
  • Extracorporeal immunoadsorption from whole blood based on the avidin-biotin concept. Evaluation of a new method
  • 1996
  • Ingår i: Acta Oncologica. - : Informa UK Limited. - 1651-226X .- 0284-186X. ; 35:3, s. 309-312
  • Tidskriftsartikel (refereegranskat)abstract
    • This study of 36 rats with rat colon adenocarcinoma transplants was carried out to investigate the efficacy of a new method of whole blood immunoadsorption (WBIA) in removing biotinylated monoclonal antibodies (MAbs) directly from unseparated blood, in order to increase 'the tumor/normal-tissue uptake ratio', as compared with extracorporeal immunoadsorption (ECIA) of antibodies from plasma. Compared with the ECIA system, the overall volume of the WBIA system (comprising only a pump, an adsorption column, a drop-chamber and tubings) was less (3.6 vs. 6.2 ml), and procedure duration 2 h less. The 17 rats undergoing the WBIA procedure, started 12 h after i.v. injection of 4.0-4.5 MBq 125I-BR96-biotin, manifested neither hemolysis nor any other complication; no signs of organ edema were found at dissection; whole body and blood radioactivity values were reduced by 51% and 89.5%, respectively. The WBIA method was as effective as ECIA, but technically simpler, safer and more reliable.
  •  
9.
  • Garkavij, Martin, et al. (författare)
  • Extracorporeal whole-blood immunoadsorption enhances radioimmunotargeting of iodine-125-labeled BR96-biotin monoclonal antibody
  • 1997
  • Ingår i: Journal of Nuclear Medicine. - 0161-5505. ; 38:6, s. 895-901
  • Tidskriftsartikel (refereegranskat)abstract
    • This study investigates the efficacy of tumor radioimmunotargeting with 125I-labeled BR96-biotin monoclonal antibody using a new method, whole-blood immunoadsorption (WBIA), based on direct adsorption of unbound monoclonal antibody (MAb) from blood without preceding separation of plasma. METHODS: Highly tumor-reactive, internalizing, chimeric BR96 MAb of isotype IgG1 binds to a tumor-associated Lewis-type (Le(Y)) cell surface antigen. Forty-six Brown Norwegian male rats were inoculated intramuscularly and beneath the liver or kidney capsule with syngeneic rat colon carcinoma BN7005, expressing Lewis-type antigen, and investigated. The rats were injected intravenously with 3.5-4.5 MBq 125I-labeled BR96-biotin. Twenty of the rats underwent WBIA starting 5 or 12 hr after injection. About six blood volumes were passed through an avidin-gel adsorption column during 2 hr. RESULTS: By using WBIA, whole-body radioactivity was reduced by 50%, and plasma activity by 85%. Both directly after completion of WBIA and 33 hr later, the activity uptake in tumors manifested only a nonsignificant decrease as compared with corresponding controls (p > 0.05) and had approximately similar time-activity curves. Uptake ratios for tumor (T):bone marrow, T:liver, T:kidney and T:lung were enhanced 2.3- to 3.5-fold in all three tumor models, as compared with controls. The ratio of liver tumor to bone marrow was improved from 10:1 to 30:1. CONCLUSION: This new method of WBIA yields significantly improved radioimmunotargeting of highly tumor-reactive, internalizing MAb BR96.
  •  
10.
  • Garkavij, Michael, et al. (författare)
  • Improving radioimmonotargeting of tumors. Variation in the amount of L6 MAb administered, combined with an immunoadsorption system (ECIA)
  • 1993
  • Ingår i: Acta Oncologica. - : Informa UK Limited. - 1651-226X .- 0284-186X. ; 32:7-8, s. 853-859
  • Tidskriftsartikel (refereegranskat)abstract
    • Extracorporeal immunoadsorption (ECIA) is a new method for the selective removal of circulating radiolabeled monoclonal antibodies (MAb) from plasma to increase the uptake in tumor versus normal tissues (T/N-ratio). To ascertain whether the amount of MAb affects T/N ratios immediately and 24 h after ECIA, we used a rat model with two tumor sites--one intramuscular (im) and one below the subrenal capsule (SR). Extracorporeal immunoadsorption was done with an avidin-agarose column after injection of 125I-labeled biotinylated L6 MAb. The animals received 10, 50 or 250 micrograms of L6 only (controls), or followed by ECIA. The efficacy of the procedure in removing plasma activity was 80-95%. For both tumor sites, the highest T/N-ratios were obtained with 10 micrograms L6. All T/N-ratios significantly improved for SR tumors by a factor ranging from 3.2 (lung) to 12.6 (bone marrow). The T/N-ratios were still elevated 24 h after ECIA. Injection of larger amounts of MAb, probably causing a higher degree of tumor saturation, will not necessarily improve the T/N ratio after ECIA.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 38

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy