SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "hsv:(MEDICIN OCH HÄLSOVETENSKAP) hsv:(Klinisk medicin) srt2:(1990-1999);srt2:(1994);lar1:(ltu)"

Sökning: hsv:(MEDICIN OCH HÄLSOVETENSKAP) hsv:(Klinisk medicin) > (1990-1999) > (1994) > Luleå tekniska universitet

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Lexell, Jan, et al. (författare)
  • Fibre type composition of rabbit tibialis anterior and extensor digitorum longus muscles
  • 1994
  • Ingår i: Journal of Anatomy. - 0021-8782 .- 1469-7580. ; 185:Pt 1, s. 95-101
  • Tidskriftsartikel (refereegranskat)abstract
    • Rabbit tibialis anterior (TA) and extensor digitorum longus (EDL) muscles are used extensively in studies of stimulation-induced fibre type transformation, but the proportions and sizes of the 2 main fibre types, and the way in which they are distributed within the muscles, have never been described in any detail. In this study, transverse sections were processed by enzyme histochemical and immunohistochemical techniques and assessed morphometrically. The data were analysed by multivariate methods. In both TA and EDL muscles, the proportion of type 1 fibres varied significantly, and to a similar extent, within a cross-section, from lateral to medial and from superficial to deep parts. The fibre density, an indirect estimate of the mean muscle fibre area, also varied significantly, but not systematically, within a cross-section. For the EDL muscle, the proportion of type 1 fibres was consistently higher in the distal than in the proximal part of the muscle. The proportion of type 1 fibres was also significantly higher in the EDL than in the TA muscle for each of the 6 rabbits. There was no systematic variation between muscles from left and right limbs. The type proportions and fibre densities for both TA and EDL muscles differed significantly between individual rabbits, but not between sexes. The study provides a database that has hitherto been lacking on normal fibre type composition and its variation within and between these experimentally important muscles.
  •  
2.
  • Eriksson, Håkan, et al. (författare)
  • A robust correlation receiver for distance estimation
  • 1994
  • Ingår i: IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control. - New York : Institute of Electrical and Electronics Engineers (IEEE). - 0885-3010 .- 1525-8955. ; 41:5, s. 596-603
  • Tidskriftsartikel (refereegranskat)abstract
    • Many methods for distance estimation, such as the ultrasonic pulse-echo method, involve the estimation of a time-of-flight (TOF). In this paper, a signal model is developed that, apart from the TOF, accounts for an unknown, linear frequency dependent distortion as well as for additive noise. We derive a TOF estimator for this model based on the criteria of maximum likelihood. The resulting receiver can be seen as an extension or generalization of the well known cross-correlation, or "matched filter", estimator described, e.g., by Nilsson. The novel receiver is found to be more robust against unknown pulse shape distortion than the cross-correlation estimator, giving less biased TOF estimates. Also, bias versus noise sensitivity can be controlled by proper model order selection
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2
Typ av publikation
tidskriftsartikel (2)
Typ av innehåll
refereegranskat (2)
Författare/redaktör
Ödling, Per (1)
Börjesson, Per Ola (1)
Eriksson, Håkan (1)
Holmer, Nils-Gunnar (1)
Lexell, Jan (1)
Jarvis, J C (1)
visa fler...
Currie, J (1)
Downham, D Y (1)
Salmons, S (1)
visa färre...
Lärosäte
Lunds universitet (2)
Blekinge Tekniska Högskola (1)
Språk
Engelska (2)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (2)
Teknik (1)
År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy