SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "hsv:(MEDICIN OCH HÄLSOVETENSKAP) hsv:(Klinisk medicin) hsv:(Kirurgi) ;pers:(Ivancev Krassi)"

Sökning: hsv:(MEDICIN OCH HÄLSOVETENSKAP) hsv:(Klinisk medicin) hsv:(Kirurgi) > Ivancev Krassi

  • Resultat 1-10 av 40
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  •  
3.
  • Resch, Timothy, et al. (författare)
  • Changes in aneurysm morphology and stent-graft configuration after endovascular repair of aneurysms of the descending thoracic aorta
  • 2001
  • Ingår i: Journal of Thoracic and Cardiovascular Surgery. - : Elsevier BV. - 1097-685X .- 0022-5223. ; 122:1, s. 47-52
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE: We sought to study changes in morphology and stent-graft configuration of descending thoracic aortic aneurysms after endovascular repair. METHODS: Twenty-three patients treated with custom-made stent-grafts were studied. The stent-graft consisted of continuous, stainless-steel Z stents mounted within a polyester graft. In the last 11 cases the stents were interconnected with 3 longitudinal wires. Contrast-enhanced spiral computed tomography was performed preoperatively and at 1, 3, and every 6 months postoperatively. Angiography was used preoperatively and at 1-year follow-up. Proximal and distal necks were assessed for diameter and length. Aneurysm diameter, endoleaks, stent-graft migration, and changes in stent-graft configuration were evaluated. RESULTS: During follow-up (median, 18 months; range, 1-48 months), excluded aneurysms decreased in diameter by 4 mm (0.5-10 mm, P =.0018). Endoleaks prevented size decrease. Five patients displayed neck dilatation, 4 at both the proximal and distal fixation sites and 1 only distally. In 7 (30%) patients there was proximal migration of the distal end of the stent-graft. Three (13%) patients displayed both distal migration of the proximal end of the stent-graft and proximal migration of the distal end of the stent-graft. There was a significant correlation between stent-graft kinking and appearance of proximal or distal stent-graft migration (P =.05 and P =.0007, respectively). In no case did the migration lead to appearance of an endoleak before intervention was performed. CONCLUSION: Excluded descending thoracic aortic aneurysms decrease in size on midterm follow-up. A subgroup of patients prone to neck dilatation might exist. A combination of neck dilatation and vector forces acting on stent-grafts in the tortuous thoracic aorta might lead to stent-graft migration.
  •  
4.
  •  
5.
  • Sörelius, Karl, et al. (författare)
  • Endovascular treatment of mycotic aortic aneurysms: a European multicenter study.
  • 2014
  • Ingår i: Circulation. - : Lippincott Williams & Wilkins. - 1524-4539 .- 0009-7322. ; 130:24, s. 2136-42
  • Tidskriftsartikel (refereegranskat)abstract
    • Mycotic aortic aneurysm (MAA) is a rare and life-threatening disease. The aim of this European multicenter collaboration was to study the durability of endovascular aortic repair (EVAR) of MAA, by assessing late infection-related complications and long-term survival.
  •  
6.
  • Alhadad, Alaa, et al. (författare)
  • Percutaneous transluminal renal angioplasty (PTRA) and surgical revascularisation in renovascular disease - A retrospective comparison of results, complications, and mortality
  • 2004
  • Ingår i: European Journal of Vascular and Endovascular Surgery. - : Elsevier BV. - 1532-2165 .- 1078-5884. ; 27:2, s. 151-156
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective. To evaluate results, complications and mortality following percutaneous transluminal renal angioplasty (PTRA) and open surgical revascularisation for renovascular disease. Methods. A retrospective evaluation of 381 renovascular patients (median age 64, range 9-99 years, 152 women) treated at Malmo University Hospital during 1987-1996. Two hundred and sixty-two (69%) of the patients were treated with PTRA, 106 (28%) with open revascularisation. Results. Thirty-day mortality was 2% in the PTRA group and 9% after open surgery (p < 0.001). There were no differences between groups concerning the number of re-do procedures, but first re-do was performed after seven (IQR 3-14) months in the PTRA group, and after 15 (IQR 10-44) months after open revascularisation (p < 0.0001). After a median follow-up of 4 months (IQR 0-13) systolic and diastolic blood pressure (BP) had decreased (p < 0.0001) in both groups. The number of antihypertensive drugs was reduced (p < 0.0001) and S-creatinine levels were unchanged in both groups. Longtime survival assessed with log-rank analysis was better (p < 0.01) in the PTRA group. The risk ratio for death with open revascularisation was 1.69 (p < 0.01). Conclusions. In this retrospective comparison, PTRA was as effective as open revascularisation, with lower complication rate and lower early and long-time mortality, but with shorter time to first re-do.
  •  
7.
  • Björses, Katarina, et al. (författare)
  • Kissingstents in the Aortic Bifurcation - a Valid Reconstruction for Aorto-iliac Occlusive Disease.
  • 2008
  • Ingår i: European journal of vascular and endovascular surgery. - : Elsevier BV. - 1532-2165 .- 1078-5884. ; Aug 7, s. 424-431
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE: To evaluate outcome and patency predicting factors of kissingstent treatment for aorto iliac occlusive disease (AIOD). METHODS: Patients treated with kissingstents for AOID between 1995 and 2004 at a tertiary referral center were identified through local databases. Chart review and preoperative images were used for TASC and Fontaine classification. Follow-up consisted of clinical exams, ABI and/or duplex. Patency rates were estimated by Kaplan-Meier analysis, and Cox multivariate regression was used to determine factors associated with patency. RESULTS: 173 consecutive patients (46% male, mean 64 years) were identified. TASC distribution was: A 15%, B 34%, C 10%, D 41%. Mean follow-up was 36 months (range: 1-144). 30-day mortality was 1% (2 patients), and 1-year survival was 91% (157 patients). 2 patients underwent late, open conversion and 13 patients suffered minor puncture site complications. Primary, assisted primary and secondary patency was: 97%, 99% and 100%, and 83%, 90% and 95% at twelve and 36 months respectively. There was no significant difference in patency between the TASC groups. Patency was significantly worse for patients in Fontaine class III. CONCLUSIONS: Aortoiliac kissing stents is a valid alternative to open repair for TASC A-D lesions. The procedure has low mortality and morbidity and good patency at 3 years.
  •  
8.
  •  
9.
  • Chuter, Timothy A M, et al. (författare)
  • A telescopic stent-graft for aortoiliac implantation
  • 1997
  • Ingår i: European Journal of Vascular and Endovascular Surgery. - 1532-2165. ; 13:1, s. 79-84
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVES: To test a new delivery system for a telescopic stent-graft. MATERIALS: Variable overlap between the components of this stent-graft combination allows length adjustment. This device differs from other multi-component stent-grafts in that both components are contained within a single delivery system. METHODS: The stent-graft was implanted in the distal thoracic to suprarenal aorta of five pigs (35-50 kg), where the arterial diameter falls by almost 50%. The proximal and distal components of the stent-graft were targeted to bony landmarks in the vertebral column. RESULTS: Inspection of completion angiograms showed both proximal and distal stent-grafts to be within 1 mm of their target locations in all five experiments. Overall combined stent-graft length varied from 13.5 cm to 16.1 cm depending on the location of the bony landmark chosen as the distal target, and on the size of the pig. CONCLUSIONS: This system may be useful for the repair of abdominal aortic aneurysm whenever preoperative sizing is difficult due to aortic tortuosity, or precluded due to the urgency of the procedure.
  •  
10.
  • Chuter, Timothy A M, et al. (författare)
  • Aneurysm pressure following endovascular exclusion
  • 1997
  • Ingår i: European Journal of Vascular and Endovascular Surgery. - 1532-2165. ; 13:1, s. 85-87
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVES: To assess the effect of stent-graft implantation on the pressure within an abdominal aortic aneurysm. METHODS: Aneurysm exclusion was performed using an aorto-uniiliac stent-graft in eight patients. Following stent-graft implantation, pressure measurements were performed through a catheter adjacent to the graft in the aneurysm. This "aneurysm pressure" was compared with radial arterial pressure. RESULTS: The pressure was lower in the aneurysm than in the radial artery, in all cases. Mean aneurysm pressure was 36.5/33.8 mmHg, while mean radial arterial pressure was 118.5/50.5 mmHg (p < 0.05, for both systolic and diastolic pressures). These findings corresponded with a reduction in the palpable abdominal pulse, and an absence of perigraft perfusion on follow-up computerised tomography. CONCLUSION: Stent-graft implantation produces a fall in the pressure within an abdominal aortic aneurysm.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 40

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy