SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "hsv:(MEDICIN OCH HÄLSOVETENSKAP) hsv:(Klinisk medicin) hsv:(Kirurgi) ;pers:(Lindstedt Ingemansson Sandra)"

Sökning: hsv:(MEDICIN OCH HÄLSOVETENSKAP) hsv:(Klinisk medicin) hsv:(Kirurgi) > Lindstedt Ingemansson Sandra

  • Resultat 1-10 av 41
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Anesäter, Erik, et al. (författare)
  • The influence on wound contraction and fluid evacuation of a rigid disc inserted to protect exposed organs during negative pressure wound therapy.
  • 2011
  • Ingår i: International Wound Journal. - 1742-481X. ; 8, s. 393-399
  • Tidskriftsartikel (refereegranskat)abstract
    • The use of a rigid disc as a barrier between the wound bed and the wound filler during negative pressure wound therapy (NPWT) has been suggested to prevent damage to exposed organs. However, it is important to determine that the effects of NPWT, such as wound contraction and fluid removal, are maintained during treatment despite the use of a barrier. This study was performed to examine the effect of NPWT on wound contraction and fluid evacuation in the presence of a rigid disc. Peripheral wounds were created on the backs of eight pigs. The wounds were filled with foam, and rigid discs of different designs were inserted between the wound bed and the foam. Wound contraction and fluid evacuation were measured after application of continuous NPWT at -80 mmHg. Wound contraction was similar in the presence and the absence of a rigid disc (84 ± 4% and 83 ± 3%, respectively, compared with baseline). Furthermore, the rigid disc did not affect wound fluid removal compared with ordinary NPWT (e.g. after 120 seconds, 71 ± 4 ml was removed in the presence and 73 ± 3 ml was removed in the absence of a disc). This study shows that a rigid barrier may be placed under the wound filler to protect exposed structures during NPWT without affecting wound contraction and fluid removal, which are two crucial features of NPWT.
  •  
2.
  • Lindstedt Ingemansson, Sandra, et al. (författare)
  • Evaluation of continuous and intermittent myocardial topical negative pressure.
  • 2008
  • Ingår i: Journal of Cardiovascular Medicine. - 1558-2027. ; 9:8, s. 813-819
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE: Topical negative pressure, commonly used in wound therapy, has been shown to increase blood flow and stimulate angiogenesis in subcutaneous tissue and skeletal muscle. In wound therapy, intermittent negative pressure is often preferred to continuous negative pressure as tissue exposed to intermittent therapy shows twice as much granulation tissue formation than that exposed to continuous pressure after 2 weeks of therapy. The present study was designed to elucidate the differences in microvascular blood flow in the left anterior descending artery area between continuous and intermittent myocardial topical negative pressure of -50 mmHg. METHODS: Six pigs underwent median sternotomy. Laser Doppler probes were inserted horizontally into the heart muscle in the left anterior descending artery area at depths of approximately 5-6 mm. Measurements of microvascular blood flow were performed in normal myocardium and ischemic myocardium during 20 min of countinuous and intermittent topical negative pressure at -50 mmHg. RESULTS: Both continuous and intermittent topical negative pressure of -50 mmHg significantly increased microvascular blood flow in the underlying myocardium: from 56.2 +/- 13.1 perfusion units (PU) before to 132.8 +/- 7.4 PU during countinuous topical negative pressure application (P < 0.05) and from 75.8 +/- 12.1 PU before to 153.6 +/- 4.7 PU during intermittent topical negative pressure application (P < 0.05). CONCLUSION: No statistically significant difference was found between microvascular blood flow during 20 min of continuous and intermittent topical negative pressure at -50 mmHg in this porcine model.
  •  
3.
  • Lindstedt Ingemansson, Sandra, et al. (författare)
  • Impact of different topical negative pressure levels on myocardial microvascular blood flow.
  • 2008
  • Ingår i: Cardiovascular Revascularization Medicine. - : Elsevier BV. - 1878-0938 .- 1553-8389. ; 9:1, s. 29-35
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: We have previously shown that a myocardial topical negative pressure (TNP) of -50 mmHg significantly increases microvascular blood flow in the underlying myocardium in normal, ischemic, and reperfused porcine myocardium. The present study was designed to elucidate the effect of different TNP levels between -50 and -150 mmHg on microvascular flow in normal and ischemic myocardium. MATERIALS AND METHODS: Seven pigs underwent median sternotomy. The microvascular blood flow in the myocardium was recorded, before and after the application of TNP, using laser Doppler velocimetry. Analyses were performed before left anterior descending artery (LAD) occlusion (normal myocardium) and after 20 min of LAD occlusion (ischemic myocardium). RESULTS: A TNP of -50 mmHg significantly increased microvascular blood flow in both normal (from 320.0+/-56.1 PU before TNP application to 435.7+/-65.5 PU after TNP application, P=.028) and ischemic myocardium (from 110.0+/-36.7 PU before TNP application to 194.3+/-56.2 PU after TNP application, P=.012). TNP between -75 and -150 mmHg showed no significant increase in microvascular blood flow in normal or ischemic myocardium. CONCLUSIONS: Of pressures between -50 and -150 mmHg, a TNP of -50 mmHg seems to be the most effective negative pressure concerning significant increase in microvascular blood flow in both normal and ischemic myocardium.
  •  
4.
  • Lindstedt Ingemansson, Sandra, et al. (författare)
  • Topical negative pressure effects on coronary blood flow in a sternal wound model.
  • 2008
  • Ingår i: International Wound Journal. - 1742-481X. ; 5:4, s. 503-509
  • Tidskriftsartikel (refereegranskat)abstract
    • Several studies have suggested that mediastinitis is a strong predictor for poor long-term survival after coronary artery bypass surgery (CABG). In those studies, several conventional wound-healing techniques were used. Previously, we have shown no difference in long-term survival between CABG patients with topical negative pressure (TNP)-treated mediastinitis and CABG patients without mediastinitis. The present study was designed to elucidate if TNP, applied over the myocardium, resulted in an increase of the total amount of coronary blood flow. Six pigs underwent median sternotomy. The coronary blood flow was measured, before and after the application of TNP (-50 mmHg), using coronary electromagnetic flow meter probes. Analyses were performed before left anterior descending artery (LAD) occlusion (normal myocardium) and after 20 minutes of LAD occlusion (ischaemic myocardium). Normal myocardium: 171.3 +/- 14.5 ml/minute before to 206.3 +/- 17.6 ml/minute after TNP application, P < 0.05. Ischaemic myocardium: 133.7 +/- 18.4 ml/minute before to 183.2 +/- 18.9 ml/minute after TNP application, P < 0.05. TNP of -50 mmHg applied over the LAD region induced a significant increase in the total coronary blood flow in both normal and ischaemic myocardium.
  •  
5.
  • Sjögren, Johan, et al. (författare)
  • Vakuumassisterad sår- behandling ger goda kliniska resultat God läkning vid komplicerade sår--djupa sternuminfektioner ett exempel.
  • 2008
  • Ingår i: Läkartidningen. - 0023-7205. ; 105:40, s. 2773-2776
  • Tidskriftsartikel (refereegranskat)abstract
    • acuum-assisted closure (V.A.C.®) is a novel treatment for wound healing, which has been used extensively during the last years in a growing number of clinical applications. This wound-healing technique is based on the application of local negative pressure to a wound. During treatment with vacuum-assisted closure, several beneficial wound healing mechanisms are initiated. Topical negative pressure increases the microvascular blood flow in the surrounding tissue and reduces wound tissue oedema and wound size. Furthermore, the stimulation of growth factors and neoangiogenesis facilitates the formation of granulation tissue in the wound. Vacuum-assisted closure has been widely adopted as a standard treatment for deep sternal wound infections following cardiac surgery since topical negative pressure combines several advantageous features from conventional surgical techniques. However, although it is effective, vacuum-assisted closure must always be used in combination with proper surgical revision and adequate antibiotic therapy in order to obtain optimal results.
  •  
6.
  •  
7.
  •  
8.
  • Lindstedt Ingemansson, Sandra, et al. (författare)
  • C-reactive protein and leucocyte counts drop faster using the HeartShield® device in patients with DSWI.
  • 2015
  • Ingår i: International Wound Journal. - : Wiley. - 1742-481X .- 1742-4801. ; 12:2, s. 189-194
  • Tidskriftsartikel (refereegranskat)abstract
    • Right ventricular heart rupture is a devastating complication associated with negative pressure wound therapy (NPWT) in cardiac surgery. The use of a rigid barrier disc (HeartShield™) has been suggested to offer protection against this lethal complication by preventing the heart from being drawn up by the negative pressure and damaged by the sharp sternum bone edges. Seven patients treated with conventional NPWT and seven patients treated with NPWT with a protective barrier disc (HeartShield) were compared with regard to bacterial clearance and infection parameters including C-reactive protein levels and leucocyte counts. C-reactive protein levels and leucocyte counts dropped faster and bacterial clearance occurred earlier in the HeartShield® group compared with the conventional NPWT group. Negative biopsy cultures were shown after 3·1 ± 0·4 NPWT dressing changes in the HeartShield group, and after 5·4 ± 0·6 NPWT dressing changes in the conventional NPWT group (P < 0·001). All patients were followed up with clinical check-up after 3 months. None of the patients in the HeartShield group had any signs of reinfection such as deep sternal wound infection (DSWI) or sternal fistulas, whereas in the conventional NPWT group, two patients had signs of sternal fistulas that demanded hospitalisation. HeartShield hiders the right ventricle to come into contact with the sharp sternal edges during NPWT and thereby protects from heart damage. This study shows that using HeartShield is beneficial in treating patients with DSWI. Improved wound healing by HeartShield may be a result of the efficient drainage of wound effluents from the thoracic cavity.
  •  
9.
  • Lindstedt Ingemansson, Sandra, et al. (författare)
  • Effects on drainage of the mediastinum and pleura during negative pressure wound therapy when using a rigid barrier to prevent heart rupture.
  • 2011
  • Ingår i: International Wound Journal. - 1742-481X. ; 8, s. 454-458
  • Tidskriftsartikel (refereegranskat)abstract
    • Right ventricular heart rupture is a devastating complication associated with negative pressure wound therapy (NPWT) following cardiac surgery. The use of a rigid disc has been suggested to offer protection against this lethal complication by preventing the heart from being drawn up towards, and damaged by, the sharp sternum edges. The aim of the present study was to compare the wound fluid evacuation from the pericardium and the left pleura when using NPWT with such a disc between the sternal edges and the heart, and when using conventional NPWT. Six pigs underwent median sternotomy followed by NPWT at -120 mmHg, using foam, with or without a rigid plastic disc between the heart and the sternal edges. A 250 ml saline was infused into the pericardium, and the time required for fluid evacuation was measured. A 500 ml saline was infused into the left pleura and the time for fluid evacuation measured. The pericardium was effectively drained of 250 ml fluid in both cases [conventional NPWT: 24 ± 0·7 seconds, NPWT with the disc: 25 ± 1·1 seconds (n.s.)]. The left pleura was effectively drained when using NPWT with the disc, but was not drained at all when using conventional NPWT. The left pleura could be effectively drained of 500 ml fluid when a rigid perforated plastic disc was inserted between the sternal edges and the heart during NPWT. Significantly less drainage of the left pleura was possible when using conventional NPWT without the disc. The pericardium was equally good drained using NPWT with or without the disc.
  •  
10.
  • Lindstedt Ingemansson, Sandra, et al. (författare)
  • Haemodynamic effects of negative pressure wound therapy when using a rigid barrier to prevent heart rupture.
  • 2011
  • Ingår i: International Wound Journal. - 1742-481X. ; 8, s. 385-392
  • Tidskriftsartikel (refereegranskat)abstract
    • Right ventricular heart rupture is a devastating complication associated with negative pressure wound therapy (NPWT) in cardiac surgery. The use of a rigid barrier has been suggested to offer protection against this lethal complication by preventing the heart from being drawn up and damaged by the sharp sternum bone edges. The aim of this study was to investigate the haemodynamic effects of placing a rigid barrier over the heart to protect it from rupture during NPWT. Eight pigs underwent median sternotomy followed by NPWT at -70 and -120 mmHg, using foam, with or without a rigid plastic disc between the heart and the sternal edges. The heart frequency, cardiac output, mean systemic arterial pressure, mean pulmonary artery pressure, central venous pressure and left atrial pressure were recorded. Cardiac output was not affected by NPWT, regardless of whether a rigid barrier was used. Heart frequency decreased during NPWT without a disc, and showed a tendency towards a decrease when using a rigid disc. The blood pressure decreased during NPWT without a disc, and showed only a tendency towards a decrease when a disc was inserted between the heart and the sternum. In conclusion, the results of this haemodynamic study show that a rigid disc can safely be placed over the heart during NPWT, to prevent heart rupture. The haemodynamic effects of NPWT in sternotomy wounds are slightly reduced by the presence of the rigid disc.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 41

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy