SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "hsv:(MEDICIN OCH HÄLSOVETENSKAP) hsv:(Klinisk medicin) hsv:(Odontologi) ;pers:(Lekholm Ulf 1944)"

Sökning: hsv:(MEDICIN OCH HÄLSOVETENSKAP) hsv:(Klinisk medicin) hsv:(Odontologi) > Lekholm Ulf 1944

  • Resultat 1-10 av 39
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Albrektsson, Tomas, 1945, et al. (författare)
  • Histologic investigations on 33 retrieved Nobelpharma implants.
  • 1993
  • Ingår i: Clinical materials. - 0267-6605. ; 12:1, s. 1-9
  • Tidskriftsartikel (refereegranskat)abstract
    • Thirty Nobelpharma implants were retrieved from 17 patients despite a remaining clinical stability, after between 1 and 16 years of clinical function. The reasons for implant removal were bone resorption in combination with soft tissue disorders, psychological causes, implant fracture and post mortem cases. When measured at the cortical passage, there was an average of 84.9% direct bone-to-implant contact and 81.8% average surface bone area in individual threads as evaluated in a computerized morphometric system at the light microscopic level.
  •  
2.
  • Becker, W, et al. (författare)
  • Five-year evaluation of implants placed at extraction and with dehiscences and fenestration defects augmented with ePTFE membranes: results from a prospective multicenter study.
  • 1999
  • Ingår i: Clinical implant dentistry and related research. - 1523-0899. ; 1:1, s. 27-32
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Barrier membranes have been used to promote bone ingrowth on implants with dehiscences and fenestrations. Membranes also have been used to protect defects adjacent to implants placed at the time of extraction. The concept of guided bone regeneration relates to preferentially allowing cells from bone to migrate into various defects while excluding fibrous tissue and epithelium. The purpose of these procedures is to enhance bone-to-implant contact at the treated sites and to prevent mucosal complications. PURPOSE: The purpose of this article is to report clinical outcomes for implants placed at the time of extraction and augmented with expanded polytetrafluoroethylene (ePTFE) and followed for 5 years. The outcomes for implants with dehiscences and fenestrations augmented with ePTFE barriers and followed up to 5 years also are reported. METHODS AND MATERIALS: Four treatment centers participated in this study (Tucson, Gothenburg, Spokane, and Leuven). In the extraction group, teeth were removed for varying reasons, and Br?nemark implants were placed and stabilized within the host bone. Defects present at the coronal implant aspect were covered with ePTFE barrier membranes. Flaps were rotated to cover the membrane-treated sites. If exposure of the material occurred prior to second-stage surgery, the membranes were removed. Barriers remaining unexposed were removed at second-stage surgery. The implants were followed up to 5 years. In the fenestration and dehiscence group, implants with exposed threads were augmented with ePTFE barrier membranes. The barriers were removed at appropriate intervals, and the patients were followed up to 5 years. Radiographic measurements were made from nonstandardized periapical radiographs at abutment connection and 1, 3, and 5-year follow-up visits. RESULTS: Forty patients participated in the extraction group. They received a total of 49 implants. Three implants failed prior to loading. The 5-year cumulative survival rates for implants placed at the time of extraction were 93.9% and 93.8%, respectively, for maxillary and mandibular implants. The average maxillary mesial and distal marginal bone loss (1-5 yr) was 0.3 mm (standard deviation [SD] = 1.5) and 0.3 mm (SD = 1.0). In mandibles, the average mesial and distal bone loss (1-5 yr) was -0.2 mm (SD = 0.5) and -0.05 mm (SD = 0.6), respectively. The dehiscence and fenestration group included 44 patients. Twenty-six were followed for up to 5 years. Eight patients experienced total implant failure. For dehiscences and fenestrations, the cumulative survival rates were 76.8% and 83.8% for maxillary and mandibular implants, respectively. The average maxillary mesial and distal bone loss (1-5 yr) was 0.4 mm (SD = 0.8) and 0.2 mm (SD = 0.9), respectively. In mandibles, the average mesial and distal marginal bone loss was 0.3 mm (SD = 0.9) and 0.3 mm (SD = 0.8), respectively. CONCLUSIONS: Implants placed at the time of extraction and augmented with ePTFE barrier membranes have favorable long-term predictability. On the other hand, long-term evaluation of implant dehiscences and fenestrations augmented with barrier membranes indicates that they have less favorable 5-year survival rates. Membrane augmentation of these may be questioned.
  •  
3.
  • Berglundh, Tord, 1954, et al. (författare)
  • Histopathological observations of human periimplantitis lesions.
  • 2004
  • Ingår i: Journal of clinical periodontology. - 0303-6979. ; 31:5, s. 341-7
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE: The aim of the present study was to analyze some characteristics of advanced and progressive periimplantitis lesions in man. MATERIAL AND METHODS: Soft tissue biopsies were obtained from 12 implants in six patients. The implants had been in function between 4 and 21 years and were, with one exception, located in the maxilla. The radiographic examination performed prior to biopsy revealed that all sites exhibited advanced bone loss. Further, clinical signs of severe inflammation, such as suppuration, swelling and/or fistula formation were detected in the majority of sites and seven of the 12 implants were found to be mobile at biopsy. Each biopsy was following fixation embedded in epoxy resin and sections were prepared for histometric and morphometric analysis. RESULTS AND CONCLUSION: It was demonstrated (i). that all soft tissue units harbored large inflammatory cell infiltrates (ICT) that extended to a position apical of a pocket epithelium and (ii). that about 60% of the lesions were occupied by inflammatory cells, among which plasma cells dominated. Numerous amounts of PMN cells occurred not only in the pocket epithelium and adjacent connective tissue areas, but were also present in peri-vascular compartments in more central areas of the ICT.
  •  
4.
  • Cardaropoli, Giuseppe, 1968, et al. (författare)
  • Peri-implant bone alterations in relation to inter-unit distances. A 3-year retrospective study.
  • 2003
  • Ingår i: Clinical oral implants research. - 0905-7161. ; 14:4, s. 430-6
  • Tidskriftsartikel (refereegranskat)abstract
    • The aim of the present retrospective study was to evaluate longitudinal alterations in radiographic bone topography at proximal sites of three-unit implant-supported fixed partial prostheses during the first 3 years after bridge installation, in relation to vertical and horizontal inter-unit distances. The subjects were partially dentate patients who had received implant-supported fixed partial prostheses during the year 1995 at the Brånemark Clinic, Göteborg, Sweden. For inclusion in the study, the patient had to have a three-unit bridge construction supported by three implants in the posterior area of the jaw. Twenty-eight patients having 35 screw-retained prostheses on Brånemark standard implants fulfilled the inclusion criteria. Radiographs obtained at bridge installation and at 1- and 3-year follow-ups were assessed for implant positions, contact point level, bone level at implants and adjacent tooth and mid-proximal bone crest level. The data were analysed with respect to two proximal units: tooth/implant units (n=35) and implant/implant units (n=70). Multiple regression analyses were used to evaluate the influence of various factors on the peri-implant and periodontal bone level changes during the 3 years of follow-up. At the tooth/implant units, the mean bone loss over the 3 years was 0.5 mm at the implant and 0.4 mm at the tooth. Multiple regression analysis failed to identify significant explanatory factors for the peri-implant/periodontal bone level changes at the tooth/implant units (R2=0.28). At the implant/implant units, the peri-implant bone loss was 0.6-0.7 mm and was significantly influenced by the vertical inter-implant distance (P<0.01), the difference in bone level at baseline between two neighbouring implants (P<0.001) and the bone level changes at the opposed implant surface (P<0.001) (R2=0.49). Furthermore, the magnitude of apical displacement of the inter-implant bone crest level during the 3 years of follow-up was negatively associated with the horizontal inter-implant distance (P<0.05). The results of the study demonstrated that both vertical and horizontal differences in implant positions might influence bone alterations in the inter-implant area during the first 3 years of loading, while the data failed to show corresponding relationships for the bone changes at the proximal area between the implant and the neighbouring tooth.
  •  
5.
  • Cardaropoli, Giuseppe, 1968, et al. (författare)
  • Tissue alterations at implant-supported single-tooth replacements: a 1-year prospective clinical study.
  • 2006
  • Ingår i: Clinical oral implants research. - : Wiley. - 0905-7161 .- 1600-0501. ; 17:2, s. 165-71
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVES: The aim of this prospective study was to evaluate dimensional alterations of the peri-implant tissues at single-tooth restorations from the time of implant placement to 1-year post-loading. MATERIAL AND METHODS: Eleven patients, aged 18-36 years, subjected to single-tooth replacements with implant-supported restorations (Brånemark implant system) in the maxillary anterior region were included in the analysis. The implant installation was performed as a two-stage procedure with a 6-month healing interval. Bone dimensions were determined by direct assessments immediately following implant placement and at abutment connection. The prosthetic restoration was placed approximately 1 month after abutment surgery. Radiographic and clinical examinations were performed at crown placement and at 1-year post-loading. Assessments of the soft tissues at the implant site and at the neighboring teeth were performed before and during implant placement, before abutment connection, after crown placement and at the 1-year follow-up examination. Mean values and standard deviations were calculated for each variable and interval, with the subject as the statistical unit. RESULTS: At the time of abutment connection, a mean loss of bone height at the facial and lingual aspect of the implant amounting to 0.7-1.3 mm (P < 0.05) was recorded, whereas no significant change was noted at proximal sites. A mean reduction of 0.4 mm of the labial bone thickness was observed between implant placement and the second-stage surgery. The radiographic bone-to-implant level showed a mean loss of 0.9 mm between abutment connection and crown placement (P<0.05) and a further 0.7 mm loss at 1 year (P < 0.05). The thickness of the labial mucosa was increased at crown placement followed by a slight remission at 1 year. During the corresponding interval, a mean apical displacement of the labial soft tissue margin of 0.6 mm had taken place (P < 0.05). A papilla fill of > or = 50% was observed at a frequency of 32% at crown placement and 86% at 1 year. CONCLUSIONS: The results demonstrated that following implant surgery remodeling takes place, which is manifested in diminished bone dimensions, both horizontally and vertically, at the facial aspect of the implant. The observed soft tissue alterations after the crown placement may affect the esthetic appeal of the restorative therapy.
  •  
6.
  • Fransson, Christer, 1956, et al. (författare)
  • Prevalence of subjects with progressive bone loss at implants.
  • 2005
  • Ingår i: Clinical oral implants research. - : Wiley. - 0905-7161. ; 16:4, s. 440-6
  • Tidskriftsartikel (refereegranskat)abstract
    • AIM: The aim of the present study was to assess the prevalence of subjects with progressive bone loss at implants with a function time of at least 5 years. MATERIAL AND METHODS: Radiographs of 1346 patients who had attended annual follow-up visits at the Brånemark Clinic, Public Dental Services, Gothenburg, Sweden were retrieved. Six hundred and sixty-two subjects fulfilled the inclusion criteria. Thus, they all had been provided with implant-supported (Brånemark System) Nobel BioCare, Gothenburg, Sweden) fixed partial or complete dentures or single-tooth replacements with a documented function time in radiographs of at least 5 years. Implants that demonstrated progressive bone loss to a level of > or =3 threads of an implant were detected. The number of subjects who exhibited one or more implants with progressive bone loss to the threshold level was recorded. RESULTS: Twenty-eight percent of 662 included subjects had one or more implants with progressive bone loss. A logistic regression analysis revealed that the individuals in this group carried a significantly larger number of implants than the subjects in whom no implants with progressive loss were detected (6 vs. 4.8). Furthermore, >30% of the subjects in the group with progressive bone loss had > or =3 identified implants and that about 33% of all such implants in this group exhibited extensive bone loss. Out of the total 3413 implants included in the study, 423 implants (12.4%) demonstrated progressive bone loss. CONCLUSION: It is suggested that the prevalence of progressive bone loss at implants assessed from subject-based data is higher than that evaluated from implant-based data.
  •  
7.
  • Friberg, Bertil, 1950, et al. (författare)
  • A comparison between cutting torque and resonance frequency measurements of maxillary implants. A 20-month clinical study.
  • 1999
  • Ingår i: International journal of oral and maxillofacial surgery. - 0901-5027. ; 28:4, s. 297-303
  • Tidskriftsartikel (refereegranskat)abstract
    • Oral implant treatment ad modum Brånemark was undertaken in nine patients with edentulous maxillae. Cutting torque measurements and resonance frequency analyses (RFA) were conducted at implant placement and the corresponding values were subjected to correlation analyses. The implants were also evaluated with RFA at abutment connection and at one-year follow-up in order to identify possible changes in implant stability. A total of 61 implants were inserted, of which 49 were of the Mk II self-tapping type. Two implants were lost during the study period. The cumulative torque was presented as a mean value for the upper/crestal, the middle and the lower/apical third of the implant site respectively, as well as an overall value for the whole site. The highest correlation (r = 0.84, P<0.05) was found when comparing the mean torque values of the upper/crestal portion with the resonance frequency values at implant placement. The Mk II implant sites were divided into three groups based on the values of the cutting torque, i.e. soft (group 1), medium (group 2) and dense bone (group 3). The mean value of each group was plotted against the corresponding mean value of resonance frequency measured at implant insertion. Statistical analysis showed significant differences in resonance frequency at implant insertion between groups 1 and 2 (P = 0.047) and between groups 1 and 3 (P = 0.002). When repeating the resonance frequency analyses at second stage surgery and at one-year follow-up, no significant differences were detected between any of the groups. It was shown that the stability of implants placed in softer bone seemed to "catch up" over time with more dense bone sites.
  •  
8.
  • Friberg, Bertil, 1950, et al. (författare)
  • A new self-tapping Brånemark implant: clinical and radiographic evaluation.
  • 1992
  • Ingår i: The International journal of oral & maxillofacial implants. - 0882-2786. ; 7:1, s. 80-5
  • Tidskriftsartikel (refereegranskat)abstract
    • A new self-tapping Brånemark implant designed for denser bone qualities was evaluated with regard to insertion technique, complications, marginal bone remodeling, and survival rate. Thirty patients, representing 21 mandibles and 9 maxillae, participated in the study. In each patient both standard and self-tapping implants were placed, and a total of 179 implants, 88 self-tapping and 91 standard, were inserted. Thirteen of 62 mandibular self-tapping implants reached their correct positions only after using the screw tap or the cylinder wrench for manual insertion. No such problems were noted when using standard fixtures after bone pre-tapping. In the maxillae, neither of the two implant designs presented any problems. One standard and one self-tapping fixture failed to osseointegrate. Radiolucencies were seen in the bone around the apical portion of two fixtures, one of each design. The mean marginal bone resorption after 1 year of follow-up was 0.5 to 0.6 mm for the two fixture types.
  •  
9.
  • Friberg, Bertil, 1950, et al. (författare)
  • Early failures in 4,641 consecutively placed Brånemark dental implants: a study from stage 1 surgery to the connection of completed prostheses.
  • 1991
  • Ingår i: The International journal of oral & maxillofacial implants. - 0882-2786. ; 6:2, s. 142-6
  • Tidskriftsartikel (refereegranskat)abstract
    • This study comprised 4,641 Brånemark dental implants, which were retrospectively followed from stage 1 surgery to completion of the prosthetic restorations. The implants were placed during a 3-year period (1986 to 1988) in 943 jaws, representing 889 patients with complete and partial edentulism. The jaw and sex distribution revealed a predominance of mandibles (564/943) and females (534/943). The mean age of the patients was 57.5 years (range 13 to 88 years) at implant placement. Only 69 (1.5%) fixtures failed to integrate, and most losses were seen in completely edentulous maxillae (46/69), in which the jaw bone exhibited soft quality and severe resorption. A preponderance of failures could also be seen among the shortest fixtures (7 mm). A majority of the mobile implants were recorded at the abutment connection (stage 2) operation (48/69).
  •  
10.
  • Friberg, Bertil, 1950, et al. (författare)
  • Evaluation of bone density using cutting resistance measurements and microradiography: an in vitro study in pig ribs.
  • 1995
  • Ingår i: Clinical oral implants research. - 0905-7161. ; 6:3, s. 164-71
  • Tidskriftsartikel (refereegranskat)abstract
    • A method using cutting resistance measurements during low-speed threading for identification of various bone densities has been evaluated with regard to its precision and potential. Pig ribs were used as test samples. Differing hand pressure, minor deviation (5 degrees) from a vertical tapping direction and individual threading did not reveal any significant differences in cutting resistance values. After implants were inserted into the threaded canals, the total bone as well as trabecular and compact bone areas surrounding the implants were calculated via a computer program and using microradiographs of the bone test samples. The outcome of the cutting resistance measurements was compared with that of the microradiographic technique, and good agreement was observed between the two procedures in the ability to identify bone density. Therefore, cutting resistance measurements may in the future also be used to clinically identify bone qualities in jaws.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 39
Typ av publikation
tidskriftsartikel (37)
forskningsöversikt (2)
Typ av innehåll
refereegranskat (39)
Författare/redaktör
Jemt, Torsten, 1950 (15)
Sennerby, Lars, 1960 (10)
Friberg, Bertil, 195 ... (10)
Gröndahl, Kerstin, 1 ... (8)
Norlund, A (4)
visa fler...
Nilner, Krister (4)
Nordenram, G. (4)
Sunnegårdh-Grönberg, ... (4)
Leonhardt, Åsa, 1964 (4)
Hultin, M (4)
Davidson, Thomas (3)
Rohlin, Madeleine (3)
Roos, J (3)
Wennström, Jan, 1947 (2)
Berglundh, Tord, 195 ... (2)
Lindhe, Jan, 1935 (2)
Cardaropoli, Giusepp ... (2)
Albrektsson, Tomas, ... (2)
Becker, W. (2)
Tranaeus, S (2)
Dahlén, Gunnar, 1944 (2)
Tranæus, Sofia (2)
Herrmann, Irene, 195 ... (2)
Helgesson, G (2)
Roos, Johan (2)
Holm, Sture, 1936 (2)
Johansson, P. (1)
Adolfsson, B (1)
Dahlin, Christer, 19 ... (1)
Rohlin, M (1)
Johansson, Carina B. ... (1)
Eriksson, A R (1)
Lindahl, L (1)
Nevins, M (1)
Oikarinen, V (1)
Astrand, P (1)
Wikström, Maude, 194 ... (1)
Davidson, Thomas, 19 ... (1)
Bergstrom, C (1)
van Steenberghe, D (1)
Higuchi, K (1)
Becker, B E (1)
Gislason, Örn, 2000 (1)
Brånemark, Per-Ingva ... (1)
Bergström, C. (1)
Gualini, Federico (1)
Jemt, T. (1)
PERSSON, LG (1)
Fransson, Christer, ... (1)
visa färre...
Lärosäte
Göteborgs universitet (39)
Umeå universitet (4)
Linköpings universitet (4)
Malmö universitet (4)
Karolinska Institutet (4)
Chalmers tekniska högskola (2)
Språk
Engelska (39)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (39)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy