SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "hsv:(MEDICIN OCH HÄLSOVETENSKAP) hsv:(Klinisk medicin) hsv:(Radiologi och bildbehandling) ;pers:(Bech Martin)"

Sökning: hsv:(MEDICIN OCH HÄLSOVETENSKAP) hsv:(Klinisk medicin) hsv:(Radiologi och bildbehandling) > Bech Martin

  • Resultat 1-10 av 43
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Peruzzi, Niccolò, et al. (författare)
  • 3D analysis of the myenteric plexus of the human bowel by X-ray phase-contrast tomography - a future method?
  • 2020
  • Ingår i: Scandinavian Journal of Gastroenterology. - : Informa UK Limited. - 0036-5521 .- 1502-7708. ; 55:10, s. 1261-1267
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVES: Light microscopical analysis in two dimensions, combined with immunohistochemistry, is presently the gold standard to describe the enteric nervous system (ENS). Our aim was to assess the usefulness of three-dimensional (3D) imaging by X-ray phase-contrast tomography in evaluating the ENS of the human bowel.MATERIAL AND METHODS: Myenteric ganglia were identified in full-thickness biopsies of the ileum and colon by hematoxylin & eosin staining. A1-mm biopsy punch was taken from the paraffin blocks and placed into a Kapton® tube for subsequent tomographic investigation. The samples were scanned, without further preparation, using phase-contrast tomography at two different scales: overview scans (performed with laboratory setups), which allowed localization of the nervous tissue (∼1µm effective voxel size); and high-resolution scans (performed with a synchrotron endstation), which imaged localized regions of 320x320x320 µm3 (176 nm effective voxel size).RESULTS: The contrast allowed us to follow the shape and the size changes of the ganglia, as well as to study their cellular components together with the cells and cellular projections of the periganglional space. Furthermore, it was possible to show the 3D network of the myenteric plexus and to quantify its volume within the samples.CONCLUSIONS: Phase-contrast X-ray tomography can be applied for volume analyses of the human ENS and to study tissue components in unstained paraffin-embedded tissue biopsies. This technique could potentially be used to study disease mechanisms, and to compare healthy and diseased tissues in clinical research.
  •  
2.
  • Andersson, Mariam, et al. (författare)
  • Axon morphology is modulated by the local environment and impacts the noninvasive investigation of its structure-function relationship
  • 2020
  • Ingår i: Proceedings of the National Academy of Sciences of the United States of America. - : Proceedings of the National Academy of Sciences. - 1091-6490. ; 117:52, s. 33649-33659
  • Tidskriftsartikel (refereegranskat)abstract
    • Axonal conduction velocity, which ensures efficient function of the brain network, is related to axon diameter. Noninvasive, in vivo axon diameter estimates can be made with diffusion magnetic resonance imaging, but the technique requires three-dimensional (3D) validation. Here, high-resolution, 3D synchrotron X-ray nano-holotomography images of white matter samples from the corpus callosum of a monkey brain reveal that blood vessels, cells, and vacuoles affect axonal diameter and trajectory. Within single axons, we find that the variation in diameter and conduction velocity correlates with the mean diameter, contesting the value of precise diameter determination in larger axons. These complex 3D axon morphologies drive previously reported 2D trends in axon diameter and g-ratio. Furthermore, we find that these morphologies bias the estimates of axon diameter with diffusion magnetic resonance imaging and, ultimately, impact the investigation and formulation of the axon structure-function relationship.
  •  
3.
  • Bech, Martin, et al. (författare)
  • In-vivo dark-field and phase-contrast x-ray imaging.
  • 2013
  • Ingår i: Scientific Reports. - : Springer Science and Business Media LLC. - 2045-2322. ; 3:Nov 13
  • Tidskriftsartikel (refereegranskat)abstract
    • Novel radiography approaches based on the wave nature of x-rays when propagating through matter have a great potential for improved future x-ray diagnostics in the clinics. Here, we present a significant milestone in this imaging method: in-vivo multi-contrast x-ray imaging of a mouse using a compact scanner. Of particular interest is the enhanced contrast in regions related to the respiratory system, indicating a possible application in diagnosis of lung diseases (e.g. emphysema).
  •  
4.
  • Bech, Martin, et al. (författare)
  • Results from the first preclinical CT scanner with grating based phase contrast and a rotating gantry
  • 2012
  • Ingår i: International Workshop on X-Ray and Neutron Phase Imaging with Gratings. - : AIP. - 1551-7616 .- 0094-243X. - 9780735410725 ; 1466, s. 130-136
  • Konferensbidrag (refereegranskat)abstract
    • After successful demonstrations of soft-tissue phase-contrast imaging with grating interferometers at synchrotron radiation sources and at laboratory based x-ray tubes, a first preclinical CT scanner with grating based phase contrast imaging modality has been constructed. The rotating gantry is equipped with a three-grating interferometer, a 50 watt tungsten anode source and a Hamamatsu flat panel detector. The total length of the interferometer is 45 cm, and the bed of the scanner is optimized for mice, with a scanning diameter of 35 mm. From one single scan both phase-contrast and standard attenuation based tomography can be attained, providing an overall gain in image contrast.
  •  
5.
  • Dahlin, Lars B., et al. (författare)
  • Three-dimensional architecture of human diabetic peripheral nerves revealed by X-ray phase contrast holographic nanotomography
  • 2020
  • Ingår i: Scientific Reports. - : Springer Science and Business Media LLC. - 2045-2322. ; 10:1
  • Tidskriftsartikel (refereegranskat)abstract
    • A deeper knowledge of the architecture of the peripheral nerve with three-dimensional (3D) imaging of the nerve tissue at the sub-cellular scale may contribute to unravel the pathophysiology of neuropathy. Here we demonstrate the feasibility of X-ray phase contrast holographic nanotomography to enable 3D imaging of nerves at high resolution, while covering a relatively large tissue volume. We show various subcomponents of human peripheral nerves in biopsies from patients with type 1 and 2 diabetes and in a healthy subject. Together with well-organized, parallel myelinated nerve fibres we show regenerative clusters with twisted nerve fibres, a sprouted axon from a node of Ranvier and other specific details. A novel 3D construction (with movie created) of a node of Ranvier with end segment of a degenerated axon and sprout of a regenerated one is captured. Many of these architectural elements are not described in the literature. Thus, X-ray phase contrast holographic nanotomography enables identifying specific morphological structures in 3D in peripheral nerve biopsies from a healthy subject and from patients with type 1 and 2 diabetes.
  •  
6.
  • Dreier, Till, et al. (författare)
  • Improved resolution in x-ray tomography by super-resolution
  • 2021
  • Ingår i: Applied Optics. - 2155-3165. ; 60:20, s. 5783-5794
  • Tidskriftsartikel (refereegranskat)abstract
    • In this paper, super-resolution imaging is described and evaluated for x-ray tomography and is compared with standard tomography and upscaling during reconstruction. Blurring is minimized due to the negligible point spread of photon counting detectors and an electromagnetically movable micro-focus x-ray spot. Scans are acquired in high and lowmagnification geometry, where the latter is used to minimize penumbral blurring fromthe x-ray source. Sharpness and level ofdetail can be significantly increased in reconstructed slices to the point where the source size becomes the limiting factor. The achieved resolution of the different methods is quantified and compared using biological samples via the edge spread function, modulation transfer function, and Fourier ring correlation.
  •  
7.
  • Dreier, Till, et al. (författare)
  • Super-resolution X-ray imaging with hybrid pixel detectors using electromagnetic source stepping
  • 2020
  • Ingår i: Journal of Instrumentation. - 1748-0221. ; 15:3
  • Tidskriftsartikel (refereegranskat)abstract
    • With increasing demand for high-resolution X-ray images, the super-resolution method allows to estimate a single high-resolution image from several low-resolution images. Hybrid pixel detectors provide high-quality and low-resolution images, which makes them particularlywell suited for super-resolution. However, such detectors consist of a limited number of pixels at high cost. Applying super-resolution with hybrid pixel detectors shows that it is a viable method to obtain high-resolution images. The point-spread function of such detectors can be idealised to be 1 pixel, adding no blur into the image making such detectors the ideal choice for the application of super- resolution X-ray imaging. However, there are charge sharing effects between the pixels caused by the energy and impact position of incoming photons. Utilising an X-ray source, which allows magnetic stepping of the X-ray spot, several slightly shifted images can be obtained without requiring mechanical movements. Registering the shifts between individual images with sub-pixel precision allows to estimate a high-resolution image. With repeatable and equally spaced X-ray spot position patterns, sufficient information can be obtained with only a few images. In this paper, we present the application of super-resolution for X-ray imaging using a Pilatus 100K hybrid pixel detector from Dectris Ltd. and a prototype micro-focus X-ray source from Excillum AB. Moreover, we analyse the image quality for applications in X-ray radiography and tomography. Using a sufficient number of low-resolution images allows us to achieve an increase in resolution, without introducing significant blur or artefacts into the image. Here we quantify the effects on the quality of resulting super-resolution images using different methods of image interpolation, interpolation factors, shifts of the sample on the detector, and amount of low-resolution images.
  •  
8.
  • Eggl, Elena, et al. (författare)
  • X-ray phase-contrast tomography with a compact laser-driven synchrotron source.
  • 2015
  • Ingår i: Proceedings of the National Academy of Sciences. - : Proceedings of the National Academy of Sciences. - 1091-6490 .- 0027-8424. ; 112:18, s. 5567-5572
  • Tidskriftsartikel (refereegranskat)abstract
    • Between X-ray tubes and large-scale synchrotron sources, a large gap in performance exists with respect to the monochromaticity and brilliance of the X-ray beam. However, due to their size and cost, large-scale synchrotrons are not available for more routine applications in small and medium-sized academic or industrial laboratories. This gap could be closed by laser-driven compact synchrotron light sources (CLS), which use an infrared (IR) laser cavity in combination with a small electron storage ring. Hard X-rays are produced through the process of inverse Compton scattering upon the intersection of the electron bunch with the focused laser beam. The produced X-ray beam is intrinsically monochromatic and highly collimated. This makes a CLS well-suited for applications of more advanced--and more challenging--X-ray imaging approaches, such as X-ray multimodal tomography. Here we present, to our knowledge, the first results of a first successful demonstration experiment in which a monochromatic X-ray beam from a CLS was used for multimodal, i.e., phase-, dark-field, and attenuation-contrast, X-ray tomography. We show results from a fluid phantom with different liquids and a biomedical application example in the form of a multimodal CT scan of a small animal (mouse, ex vivo). The results highlight particularly that quantitative multimodal CT has become feasible with laser-driven CLS, and that the results outperform more conventional approaches.
  •  
9.
  •  
10.
  • Einarsdóttir, Hildur, et al. (författare)
  • Computer-aided diagnosis of pulmonary diseases using x-ray darkfield radiography
  • 2015
  • Ingår i: Physics in Medicine and Biology. - : IOP Publishing. - 0031-9155 .- 1361-6560. ; 60:24, s. 9253-9268
  • Tidskriftsartikel (refereegranskat)abstract
    • In this work we develop a computer-aided diagnosis (CAD) scheme for classification of pulmonary disease for grating-based x-ray radiography. In addition to conventional transmission radiography, the grating-based technique provides a dark-field imaging modality, which utilizes the scattering properties of the x-rays. This modality has shown great potential for diagnosing early stage emphysema and fibrosis in mouse lungs in vivo. The CAD scheme is developed to assist radiologists and other medical experts to develop new diagnostic methods when evaluating grating-based images. The scheme consists of three stages: (i) automatic lung segmentation; (ii) feature extraction from lung shape and dark-field image intensities; (iii) classification between healthy, emphysema and fibrosis lungs. A study of 102 mice was conducted with 34 healthy, 52 emphysema and 16 fibrosis subjects. Each image was manually annotated to build an experimental dataset. System performance was assessed by: (i) determining the quality of the segmentations; (ii) validating emphysema and fibrosis recognition by a linear support vector machine using leave-one-out cross-validation. In terms of segmentation quality, we obtained an overlap percentage (Ω) 92.63 ± 3.65%, Dice Similarity Coefficient (DSC) 89.74 ± 8.84% and Jaccard Similarity Coefficient 82.39 ± 12.62%. For classification, the accuracy, sensitivity and specificity of diseased lung recognition was 100%. Classification between emphysema and fibrosis resulted in an accuracy of 93%, whilst the sensitivity was 94% and specificity 88%. In addition to the automatic classification of lungs, deviation maps created by the CAD scheme provide a visual aid for medical experts to further assess the severity of pulmonary disease in the lung, and highlights regions affected.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 43

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy