1.
  • Arlig, A, et al. (författare)
  • Attenuation correction in quantitative SPECT of cerebral blood flow: a Monte Carlo study
  • 2000
  • Ingår i: Physics in Medicine and Biology. - : IOP Publishing. - 1361-6560 .- 0031-9155. ; 45:12, s. 3847-3859
  • Tidskriftsartikel (refereegranskat)abstract
    • Monte Carlo simulation has been used to produce projections from a voxel-based brain phantom, simulating a 99mTc-HMPAO single photon emission computed tomography (SPECT) brain investigation. For comparison, projections free from the effects of attenuation and scattering were also simulated, giving ideal transaxial images after reconstruction. Three methods of attenuation correction were studied: (a) a pre-processing method, (b) a post-processing uniform method and (c) a post-processing non-uniform method using a density map. The accuracy of these methods was estimated by comparison of the reconstructed images with the ideal images using the normalized mean square error, NMSE, and quantitative values of the regional cerebral blood flow, rCBF. A minimum NMSE was achieved for the effective linear attenuation coefficient mu(eff) = 0.07 (0.09) cm(-1) for the uniform(pre) method, the effective mass attenuation coefficient mu(eff)/rho = 0.08 (0.10) cm2 g(-1) for the uniform(post) method and mu(eff)/rho = 0.12 (0.13) cm2 g(-1) for the non-uniform(post) method. Values in parentheses represent the case of dual-window scatter correction. The non-uniform(post) method performed better, as measured by the NMSE, both with and without scatter correction. Furthermore, the non-uniform(post) method gave, on average, more accurate rCBF values. Although the difference in rCBF accuracy was small between the various methods, the same method should be used for patient studies as for the reference material.
  •  
2.
  •  
3.
  • Gustafsson, Agnetha, 1960-, et al. (författare)
  • Dual-window scatter correction and energy window setting in cerebral blood flow SPECT: a Monte Carlo study
  • 2000
  • Ingår i: Physics in Medicine and Biology. - : IOP Publishing. - 1361-6560 .- 0031-9155. ; 45:11, s. 3431-3440
  • Tidskriftsartikel (refereegranskat)abstract
    • The image quality in SPECT studies of the regional cerebral blood flow (rCBF) performed with 99mTc-HMPAO is degraded by scattered photons. The finite energy resolution of the gamma camera makes the detection of scattered photons unavoidable, and this is observed in the image as an impaired contrast between grey and white matter structures. In this work, a Monte Carlo simulated SPECT study of a realistic voxel-based brain phantom was used to evaluate the resulting contrast-to-noise ratio for a number of energy window settings, with and without the dual-window scatter correction. Values of the scaling factor k, used to obtain the fraction of scattered photons in the photopeak window, were estimated for each energy window. The use of a narrower, asymmetric, energy discrimination window improved the contrast, with a subsequent increase in statistical noise due to the lower number of counts. The photopeak-window setting giving the best contrast-to-noise ratio was found to be the same whether or not scatter correction was applied. Its value was 17% centred at 142 keV. At the optimum photopeak-window setting, the contrast was improved by using scatter correction, but the contrast-to-noise ratio was made worse.
  •  
4.
  •  