1.
  •  
2.
  • Olivecrona, Henrik, et al. (författare)
  • A new CT method for measuring cup orientation after total hip arthroplasty : A study of 10 patients
  • 2004
  • Ingår i: Acta Orthopaedica Scandinavica. - : Medical Journals Sweden AB. - 0001-6470. ; 75:3, s. 252-260
  • Tidskriftsartikel (refereegranskat)abstract
    • Background It is difficult to assess the orientation of the acetabular component on routine radiographs. We present a method for determining the spatial orientation of the acetabular component after total hip arthroplasty (THA) using computed tomography. Patients and methods Two CT-scans, 10 min apart, were obtained from each of 10 patients after THA. Using locally developed software, two independent examiners measured the orientation of the acetabular component in relation to the pelvis. The measurements were repeated after one week. To be independent of the patient position during scanning, the method involved two steps. Firstly, a 3D volumetric image of the pelvis was brought into a standard pelvic orientation, then the orientation of the acetabular component was measured. The orientation of the acetabular component was expressed as operative anteversion and inclination relative to an internal pelvic reference coordinate system. To evaluate precision, we compared measurements across pairs of CT volumes between observers and trials. Results Mean absolute interobserver angle error was 2.3degrees for anteversion (range 0-6.6degrees), and 1.1degrees for inclination (range 0-4.6degrees). For interobserver measurements, the precision, defined as one standard deviation, was 2.9degrees for anteversion, and 1.5degrees for inclination. A Student's West showed that the overall differences between the examiners, trials, and cases were not significant. Data were normally distributed and were not dependent on examiner or trial. Interpretation We conclude that the implant angles of the acetabular component in relation to the pelvis could be detected repeatedly using CT, independently of patient positioning.
  •  
3.
  • Olivecrona, Henrik, et al. (författare)
  • Spatial component position in total hip arthroplasty - Accuracy and repeatability with a new CT method
  • 2003
  • Ingår i: Acta Radiologica. - : SAGE Publications. - 0284-1851 .- 1600-0455. ; 44:1, s. 84-91
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: 3D detection of centerpoints of prosthetic cup and head after total hip arthroplasty (THA) using CT. Material and Methods: Two CT examinations, 10 min apart, were obtained from each of 10 patients after THA. Two independent examiners placed landmarks in images of the prosthetic cup and head. All landmarking was repeated after 1 week. Centerpoints were calculated and compared. Results: Within volumes, all measurements of centerpoints of cup and head fell, with a 95% confidence, within one CT-voxel of any other measurement of the same object. Across two volumes, the mean error of distance between center of cup and prosthetic head was 1.4 mm (SD 0.73). Intra- and interobserver 95% accuracy limit was below 2 mm within and below 3 mm across volumes. No difference between intra- and interobserver measurements occurred. A formula for converting finite sets of point landmarks in the radiolucent tread of the cup to a centerpoint was stable. The percent difference of the landmark distances from a calculated spherical surface was within one CT-voxel. This data was normally distributed and not dependent on observer or trial. Conclusion: The true 3D position of the centers of cup and prosthetic head can be detected using CT. Spatial relationship between the components can be analyzed visually and numerically.
  •  
4.
  • Olivecrona, Lotta, et al. (författare)
  • Acetabular component migration in total hip arthroplasty using CT and a semiautomated program for volume merging
  • 2002
  • Ingår i: Acta Radiologica. - : SAGE Publications. - 0284-1851 .- 1600-0455. ; 43:5, s. 517-527
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To develop a non-invasive method for detection of acetabular cup migration after total hip arthroplasty (THA) with a higher degree of accuracy than routine plain radiography. Material and Methods: Two CT examinations, 10 min apart, were obtained from each of 10 patients that had undergone THA. Using an in-house developed semiautomated program for volume merging, the pelves in the two examinations were fused and the acetabular cup was visually and numerically evaluated to test the method's accuracy in detecting migration. Results: In the visual evaluation of the best match a 1-mm translation of the cup was detectable. The numerical evaluation, comparing landmarks placed in the images of the acetabular cup and the head of the femur component in the two examinations, showed the mean difference in orientation of acetabular axes to be 2.5degrees, the mean distance between centre of cup face to be 2.5 mm and the mean distance between centre of the head of the prosthetic femoral component to be 1 mm. Conclusion: This method has a significantly higher accuracy than routine plain radiography in detecting acetabular cup migration and could be used in clinical practice. It gives both a visual and a numerical correlate to migration.
  •  
5.
  • Olivecrona, Lotta, et al. (författare)
  • Model studies on acetabular component migration in total hip arthroplasty using CT and a semiautomated program for volume merging
  • 2003
  • Ingår i: Acta Radiologica. - : SAGE Publications. - 0284-1851 .- 1600-0455. ; 44:4, s. 419-429
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: Validation of a non-invasive CT method for detection of acetabular cup migration after total hip arthroplasty in a phantom study. Material and Methods: 26 CT examinations were obtained of a pelvic model while altering the position of the acetabular cup. Using a previously described program for volume merging, the pelvi in different examinations were fused and the 3D alterations of the position of the acetabular cup were evaluated visually and numerically and correlated to direct measurements on the model. Results: Visually, two independent examiners differentiated between 0, 1 and 2 to 3 mm migration with 100% specificity and sensitivity. Numerically, the mean error over all cases between model and CT measurements was 0.04 mm (SD +/- 0.33). The mean absolute error between model and CT data was 0.26 mm (SD +/- 0.19). Intra- and interobserver 95% accuracy and repeatability limits were below 0.5/0.7 mm, respectively. No significant interobserver difference occurred. The data were normally distributed and not dependent on observer. Conclusion: The accuracy of this non-invasive method out-performs routine plain radiography. The method gives both visual and numerical correlates to migration and can be used in clinical practice.
  •  
6.
  • Trulsson, M, et al. (författare)
  • Cortical responses to single mechanoreceptive afferent microstimulation revealed with fMRI
  • 2001
  • Ingår i: NeuroImage. - : Academic Press. - 1053-8119 .- 1095-9572. ; 13:4, s. 613-622
  • Tidskriftsartikel (refereegranskat)abstract
    • The technique of intraneural microneurography/microstimulation has been used extensively to study contributions of single, physiologically characterized mechanoreceptive afferents (MRAs) to properties of somatosensory experience in awake human subjects. Its power as a tool for sensory neurophysiology can be greatly enhanced, however, by combining it with functional neuroimaging techniques that permit simultaneous measurement of the associated CNS responses. Here we report its successful adaptation to the environment of a high-field MR scanner. Eight median-nerve MRAs were isolated and characterized in three subjects and microstimulated in conjunction with fMRI at 3.0 T. Hemodynamic responses were observed in every case, and these responses were robust, focal, and physiologically orderly. The combination of fMRI with microstimulation will enable more detailed studies of the representation of the body surface in human somatosensory cortex and further studies of the relationship of that organization to short-term plasticity in the human SI cortical response to natural tactile stimuli. It can also be used to study many additional topics in sensory neurophysiology, such as CNS responses to additional classes of afferents and the effects of stimulus patterning and unimodal/crossmodal attentional manipulations. Finally, it presents unique opportunities to investigate the basic physiology of the BOLD effect and to compare the operating characteristics of fMRI and EEG as human functional neuroimaging modalities in an unusually specific and well-characterized neurophysiological setting.
  •  
7.
  • Qatarneh, Sharif M., et al. (författare)
  • Evaluation of a segmentation procedure to delineate organs for use in construction of a radiation therapy planning atlas
  • 2003
  • Ingår i: International Journal of Medical Informatics. - 1386-5056 .- 1872-8243. ; 69, s. 39-55
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives: This paper evaluates a semi-automatic segmentation procedure to enhance utilizing atlas based treatment plans. For this application, it is crucial to provide a collection of 'reference' organs, restorable from the atlas so that they closely match those of the current patient. To enable assembling representative organs, we developed a semiautomatic procedure using an active contour method. Method: The 3D organ volume was identified by defining contours on individual slices. The initial organ contours were matched to patient volume data sets and then superimposed on them. These starting contours were then adjusted and refined to rapidly find the organ outline of the given patient. Performance was evaluated by contouring organs of different size, shape complexity, and proximity to surrounding structures. We used representative organs defined on CT volumes obtained from 12 patients and compared the resulting outlines to those drawn by a radiologist. Results: A strong correlation was found between the area measures of the delineated liver (r = 0.992), lung (r = 0.996) and spinal cord (r = 0.81), obtained by both segmentation techniques. A paired Student's t-test showed no statistical difference between the two techniques regarding the liver and spinal cord (p > 0.05). Conclusion: This method could be used to form 'standard' organs, which would form part of a whole body atlas (WBA) database for radiation treatment plans as well as to match atlas organs to new patient data.
  •  
8.
  •  
9.
  •  
10.
  •  