SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "hsv:(MEDICIN OCH HÄLSOVETENSKAP) hsv:(Klinisk medicin) hsv:(Radiologi och bildbehandling) srt2:(2000-2004);pers:(Maguire Jr. Gerald Q.)"

Sökning: hsv:(MEDICIN OCH HÄLSOVETENSKAP) hsv:(Klinisk medicin) hsv:(Radiologi och bildbehandling) > (2000-2004) > Maguire Jr. Gerald Q.

  • Resultat 1-10 av 18
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Olivecrona, Henrik, et al. (författare)
  • A new CT method for measuring cup orientation after total hip arthroplasty : A study of 10 patients
  • 2004
  • Ingår i: Acta Orthopaedica Scandinavica. - : Medical Journals Sweden AB. - 0001-6470. ; 75:3, s. 252-260
  • Tidskriftsartikel (refereegranskat)abstract
    • Background It is difficult to assess the orientation of the acetabular component on routine radiographs. We present a method for determining the spatial orientation of the acetabular component after total hip arthroplasty (THA) using computed tomography. Patients and methods Two CT-scans, 10 min apart, were obtained from each of 10 patients after THA. Using locally developed software, two independent examiners measured the orientation of the acetabular component in relation to the pelvis. The measurements were repeated after one week. To be independent of the patient position during scanning, the method involved two steps. Firstly, a 3D volumetric image of the pelvis was brought into a standard pelvic orientation, then the orientation of the acetabular component was measured. The orientation of the acetabular component was expressed as operative anteversion and inclination relative to an internal pelvic reference coordinate system. To evaluate precision, we compared measurements across pairs of CT volumes between observers and trials. Results Mean absolute interobserver angle error was 2.3degrees for anteversion (range 0-6.6degrees), and 1.1degrees for inclination (range 0-4.6degrees). For interobserver measurements, the precision, defined as one standard deviation, was 2.9degrees for anteversion, and 1.5degrees for inclination. A Student's West showed that the overall differences between the examiners, trials, and cases were not significant. Data were normally distributed and were not dependent on examiner or trial. Interpretation We conclude that the implant angles of the acetabular component in relation to the pelvis could be detected repeatedly using CT, independently of patient positioning.
  •  
2.
  •  
3.
  • Olivecrona, Henrik, et al. (författare)
  • Spatial component position in total hip arthroplasty - Accuracy and repeatability with a new CT method
  • 2003
  • Ingår i: Acta Radiologica. - : SAGE Publications. - 0284-1851 .- 1600-0455. ; 44:1, s. 84-91
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: 3D detection of centerpoints of prosthetic cup and head after total hip arthroplasty (THA) using CT. Material and Methods: Two CT examinations, 10 min apart, were obtained from each of 10 patients after THA. Two independent examiners placed landmarks in images of the prosthetic cup and head. All landmarking was repeated after 1 week. Centerpoints were calculated and compared. Results: Within volumes, all measurements of centerpoints of cup and head fell, with a 95% confidence, within one CT-voxel of any other measurement of the same object. Across two volumes, the mean error of distance between center of cup and prosthetic head was 1.4 mm (SD 0.73). Intra- and interobserver 95% accuracy limit was below 2 mm within and below 3 mm across volumes. No difference between intra- and interobserver measurements occurred. A formula for converting finite sets of point landmarks in the radiolucent tread of the cup to a centerpoint was stable. The percent difference of the landmark distances from a calculated spherical surface was within one CT-voxel. This data was normally distributed and not dependent on observer or trial. Conclusion: The true 3D position of the centers of cup and prosthetic head can be detected using CT. Spatial relationship between the components can be analyzed visually and numerically.
  •  
4.
  • Olivecrona, Henrik, et al. (författare)
  • Stability of acetabular axis after total hip arthroplasty, repeatability using CT and a semiautomated program for volume fusion
  • 2003
  • Ingår i: Acta Radiologica. - : SAGE Publications. - 0284-1851 .- 1600-0455. ; 44:6, s. 653-661
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To validate a CT method for detecting changes in acetabular cup orientation after THA. Material and Methods: 26 CT examinations were obtained from a pelvic model with an uncemented acetabular cup. The model position was altered between acquisitions, but the cup axis angle vis-a-vis the pelvis was maintained. Data sets were combined into 37 pairs, each containing a unique positioning error. The pelvi in different examinations were fused, creating transformed volumes. Landmarks corresponding to the cup before and after fusion were placed interactively by two independent examiners. The orientation of the acetabular axis was calculated for each volume and compared across volumes. Results: Before fusion the mean angle error between the acetabular axes was 4.17degrees (SD +/- 1.95degrees). After fusion the mean angle error was 0.36degrees (SD +/- 0.17). The 95% repeatability limits were below 0.7degrees. There was no significant interobserver difference. Analysis of the cup landmarking pattern by condition numbers and individual landmark errors showed stability. Conclusion: Non-invasive fusion of CT volumes and a stable landmarking pattern for the acetabular cup outperforms routine plain radiography in detecting changes in the orientation of the acetabular axis over time. The method delivers both visual and numerical output and could be used in clinical practice.
  •  
5.
  • Olivecrona, Lotta, et al. (författare)
  • Acetabular component migration in total hip arthroplasty using CT and a semiautomated program for volume merging
  • 2002
  • Ingår i: Acta Radiologica. - : SAGE Publications. - 0284-1851 .- 1600-0455. ; 43:5, s. 517-527
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To develop a non-invasive method for detection of acetabular cup migration after total hip arthroplasty (THA) with a higher degree of accuracy than routine plain radiography. Material and Methods: Two CT examinations, 10 min apart, were obtained from each of 10 patients that had undergone THA. Using an in-house developed semiautomated program for volume merging, the pelves in the two examinations were fused and the acetabular cup was visually and numerically evaluated to test the method's accuracy in detecting migration. Results: In the visual evaluation of the best match a 1-mm translation of the cup was detectable. The numerical evaluation, comparing landmarks placed in the images of the acetabular cup and the head of the femur component in the two examinations, showed the mean difference in orientation of acetabular axes to be 2.5degrees, the mean distance between centre of cup face to be 2.5 mm and the mean distance between centre of the head of the prosthetic femoral component to be 1 mm. Conclusion: This method has a significantly higher accuracy than routine plain radiography in detecting acetabular cup migration and could be used in clinical practice. It gives both a visual and a numerical correlate to migration.
  •  
6.
  • Olivecrona, Lotta, et al. (författare)
  • Model studies on acetabular component migration in total hip arthroplasty using CT and a semiautomated program for volume merging
  • 2003
  • Ingår i: Acta Radiologica. - : SAGE Publications. - 0284-1851 .- 1600-0455. ; 44:4, s. 419-429
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: Validation of a non-invasive CT method for detection of acetabular cup migration after total hip arthroplasty in a phantom study. Material and Methods: 26 CT examinations were obtained of a pelvic model while altering the position of the acetabular cup. Using a previously described program for volume merging, the pelvi in different examinations were fused and the 3D alterations of the position of the acetabular cup were evaluated visually and numerically and correlated to direct measurements on the model. Results: Visually, two independent examiners differentiated between 0, 1 and 2 to 3 mm migration with 100% specificity and sensitivity. Numerically, the mean error over all cases between model and CT measurements was 0.04 mm (SD +/- 0.33). The mean absolute error between model and CT data was 0.26 mm (SD +/- 0.19). Intra- and interobserver 95% accuracy and repeatability limits were below 0.5/0.7 mm, respectively. No significant interobserver difference occurred. The data were normally distributed and not dependent on observer. Conclusion: The accuracy of this non-invasive method out-performs routine plain radiography. The method gives both visual and numerical correlates to migration and can be used in clinical practice.
  •  
7.
  • Dewyngaert, J. Keith, et al. (författare)
  • Procedure for unmasking localization information from ProstaScint scans for prostate radiation therapy treatment planning
  • 2004
  • Ingår i: International Journal of Radiation Oncology, Biology, Physics. - : Elsevier BV. - 0360-3016 .- 1879-355X. ; 60:2, s. 654-662
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To demonstrate a method to extract the meaningful biologic information from In-111-radiolabeled capromab pendetide (ProstaScint) SPECT scans for use in radiation therapy treatment planning by removing that component of the In-111 SPECT images associated with normal structures. Methods and Materials: We examined 20 of more than 80 patients who underwent simultaneous Tc-99m/In-111 SPECT scans, which were subsequently registered to the corresponding CT/MRI scans. A thresholding algorithm was used to identify Tc-99m uptake associated with blood vessels and CT electron density associated with bone marrow. Corresponding voxels were removed from the In-111 image set. Results: No single threshold value was found to be associated with the Tc-99m uptake that corresponded to the blood vessels. Intensity values were normalized to a global maximum and, as such, were dependent upon the quantity of Tc-99m pooled in the bladder. The reduced ProstaScint volume sets were segmented by use of a thresholding feature of the planning system and superimposed on the CT/MRI scans. Conclusions: ProstaScint images are now closer to becoming a biologically and therapeutically useful and accurate image set. After known sources of normal intensity are stripped away, the remaining areas that demonstrate uptake may be segmented and superimposed on the treatment-planning CT/MRI volume.
  •  
8.
  • Qatarneh, Sharif M., et al. (författare)
  • Evaluation of a segmentation procedure to delineate organs for use in construction of a radiation therapy planning atlas
  • 2003
  • Ingår i: International Journal of Medical Informatics. - 1386-5056 .- 1872-8243. ; 69, s. 39-55
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives: This paper evaluates a semi-automatic segmentation procedure to enhance utilizing atlas based treatment plans. For this application, it is crucial to provide a collection of 'reference' organs, restorable from the atlas so that they closely match those of the current patient. To enable assembling representative organs, we developed a semiautomatic procedure using an active contour method. Method: The 3D organ volume was identified by defining contours on individual slices. The initial organ contours were matched to patient volume data sets and then superimposed on them. These starting contours were then adjusted and refined to rapidly find the organ outline of the given patient. Performance was evaluated by contouring organs of different size, shape complexity, and proximity to surrounding structures. We used representative organs defined on CT volumes obtained from 12 patients and compared the resulting outlines to those drawn by a radiologist. Results: A strong correlation was found between the area measures of the delineated liver (r = 0.992), lung (r = 0.996) and spinal cord (r = 0.81), obtained by both segmentation techniques. A paired Student's t-test showed no statistical difference between the two techniques regarding the liver and spinal cord (p > 0.05). Conclusion: This method could be used to form 'standard' organs, which would form part of a whole body atlas (WBA) database for radiation treatment plans as well as to match atlas organs to new patient data.
  •  
9.
  • Aitken, Candice L., et al. (författare)
  • Tumor localization and image registration of F-18FDG coincidence detection scans with computed tomographic scans
  • 2002
  • Ingår i: Clinical Nuclear Medicine. - : Ovid Technologies (Wolters Kluwer Health). - 0363-9762 .- 1536-0229. ; 27:4, s. 275-282
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: The aim of this study was to determine the feasibility of registering routine clinical F-18 fluorodeoxyglucose (FDG) coincidence detection (CD) scans with computed tomographic (CT) scans for radiation treatment planning and case management. Methods: F-18 FDG CD and chest CT scans, performed in 10 randomly selected patients with confirmed or possible adenocarcinoma of the lung, were evaluated. The quality of the matches was verified by comparisons of the center-to-center distance between a region of interest (ROI) manually drawn on the CT slice and warped onto the CD slice with an ROI drawn manually directly on the CD slice. In addition, the overlap between the two ROIs was calculated. Results: All 10 F-18 FDG CD and CT scans were registered with good superimposition of soft tissue density on increased radionuclide activity. The center-to-center distance between the ROIs ranged from 0.29 mm to 8.08 mm, with an average center-to-center distance of 3.89 mm 2.42 mm (0.69 pixels +/- 0.34 pixels). The ROI overlap ranged from 77% to 99%, with an average of 90% +/- 5.6%. Conclusions: Although the use of F-18 FDG CD shows great promise for the identification of tumors, it shares the same drawbacks as those associated with radiolabeled monoclonal antibody SPECT and ligand-based positron emission tomographic scans in that anatomic markers are limited. This study shows that image registration is feasible and may improve the clinical relevance of CD images.
  •  
10.
  • Crafoord, Joakim, et al. (författare)
  • Comparison of two landmark based image registration methods for use with a body atlas
  • 2000
  • Ingår i: Physica medica (Testo stampato). - 1120-1797 .- 1724-191X. ; 16:2, s. 75-82
  • Tidskriftsartikel (refereegranskat)abstract
    • We describe preliminary work registering abdominal MRI images from three healthy male volunteers. Anatomically selected 3D homologous point pairs (landmarks), from which eigenvalues were generated to form the basis for a 3D non-affine polynomial transformation, were placed on axial slices alone and on axial, coronal and sagittal slices. Registration accuracy was judged visually by comparing superimposed 3D isosurfaces from the reference, untransformed, and transformed volume data and by comparing merged 2D slices projected fi om the transformed and reference volume data superimposed with 2D isolines. The squared sum of intensity differences between the transformed/untransformed and the reference volume was significant at the 0.05 (p >0.05) confidence level. The correlation coefficient improved by an average of 38% and the cross correlation between pixel values improved by an average of 22%. In each trial, the standard deviation of the landmarks after transformation was within one voxel and the standard error of the mean was not significantly different from zero at the 0.05 confidence level. Abdominal isosurface volume differences (between individuals) changed from an average of 14.5% before registration to 2.9% after registration. This experiment shows that it is possible to choose landmarks such that abdominal data from different subject volumes can be mapped to a common reference, and thus that it is possible to use this combined volume both to form an atlas and to warp abdominal data from an atlas to a patient volume.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 18

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy