1.
  • Björkman-Burtscher, Isabella, et al. (författare)
  • Proton MR spectroscopy and preoperative diagnostic accuracy: an evaluation of intracranial mass lesions characterized by stereotactic biopsy findings
  • 2000
  • Ingår i: AJNR. - 1936-959X. ; 21:1, s. 84-93
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND AND PURPOSE: MR imaging has made it easier to distinguish among the different types of intracranial mass lesions. Nevertheless, it is sometimes impossible to base a diagnosis solely on clinical and neuroradiologic findings, and, in these cases, biopsy must be performed. The purpose of this study was to evaluate the hypothesis that proton MR spectroscopy is able to improve preoperative diagnostic accuracy in cases of intracranial tumors and may therefore obviate stereotactic biopsy. METHODS: Twenty-six patients with intracranial tumors underwent MR imaging, proton MR spectroscopy, and stereotactic biopsy. MR spectroscopic findings were evaluated for the distribution pattern of pathologic spectra (NAA/Cho ratio < 1) across the lesion and neighboring tissue, for signal ratios in different tumor types, and for their potential to improve preoperative diagnostic accuracy. RESULTS: Gliomas and lymphomas showed pathologic spectra outside the area of contrast enhancement while four nonastrocytic circumscribed tumors (meningioma, pineocytoma, metastasis, and germinoma) showed no pathologic spectra outside the region of enhancement. No significant correlation was found between different tumor types and signal ratios. MR spectroscopy improved diagnostic accuracy by differentiating infiltrative from circumscribed tumors; however, diagnostic accuracy was not improved in terms of differentiating the types of infiltrative or circumscribed lesions. CONCLUSION: MR spectroscopy can improve diagnostic accuracy by differentiating circumscribed brain lesions from histologically infiltrating processes, which may be difficult or impossible solely on the basis of clinical or neuroradiologic findings.
  •  
2.
  • Wirestam, Ronnie, et al. (författare)
  • Regional cerebral blood flow distributions in normal volunteers: dynamic susceptibility contrast MRI compared with 99mTc-HMPAO SPECT
  • 2000
  • Ingår i: Journal of Computer Assisted Tomography. - 1532-3145. ; 24:4, s. 526-530
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: Relative regional cerebral blood flow (rCBF) at rest was measured in 44 volunteers using both dynamic susceptibility contrast (DSC) MRI and (99m)Tc-HMPAO SPECT on the same day. METHOD: In MRI, a Gd-DTPA-BMA contrast agent bolus (0.3 mmol/kg body wt) was monitored with a simultaneous dual FLASH pulse sequence (time resolution 1.5 s). MRI-based rCBF images were calculated by singular value decomposition-based deconvolution of the measured tissue concentration-time curve with an arterial input function from a small artery within the imaging slice. In the SPECT investigation, 900 MBq of (99m)Tc-HMPAO was injected intravenously. Relative rCBF in gray matter in the thalamus and in frontal white matter was determined. RESULTS: The ratio of relative rCBF in gray matter to relative rCBF in white matter was 2.21 +/- 0.57 using MRI and 2.24 +/- 0.54 using SPECT (mean +/- SD). CONCLUSION: Relative rCBF maps from DSC MRI and (99m)Tc-HMPAO SPECT showed good agreement, and the MRI-based rCBF ratio correlated with the corresponding SPECT-based ratio (r = 0.79, p < 0.0000006).
  •  
3.
  • Brockstedt, Sara, et al. (författare)
  • High-resolution diffusion imaging using phase-corrected segmented echo-planar imaging
  • 2000
  • Ingår i: Magnetic Resonance Imaging. - 1873-5894. ; 18:6, s. 649-657
  • Tidskriftsartikel (refereegranskat)abstract
    • Diffusion magnetic resonance imaging (MRI) was performed with a high-resolution segmented echo-planar imaging technique, which provided images with substantially less susceptibility artifacts than images obtained with single-shot echo-planar imaging (EPI). Diffusion imaging performed with any multishot pulse sequence is inherently sensitive to motion artifacts and in order to reduce motion artifacts, the presented method utilizes navigator echo phase corrections, performed after a one-dimensional Fourier transform along the frequency-encoding direction. Navigator echo phases were fitted to a straight line prior to phase correction to avoid errors from internal motion. In vivo imaging was performed using electro cardiographic (ECG) triggering. Apparent diffusion coefficient (ADC) maps were calculated on a pixel-by-pixel basis using up to seven diffusion sensitivities, ranging from b = 0 to 1129 x 10(6) s/m(2).
  •  
4.
  • Engellau, Lena, et al. (författare)
  • MR evaluation ex vivo and in vivo of a covered stent-graft for abdominal aortic aneurysms: ferromagnetism, heating, artifacts, and velocity mapping
  • 2000
  • Ingår i: Journal of Magnetic Resonance Imaging. - 1522-2586. ; 12:1, s. 112-121
  • Tidskriftsartikel (refereegranskat)abstract
    • Magnetic resonance imaging (MRI) safety was evaluated at 1.5 T in a covered nickel titanium stent-graft (Vanguard) used for endovascular treatment of abdominal aortic aneurysms (AAAs). Imaging artifacts were assessed on MRI with contrast-enhanced (CE) three-dimensional (3D) MR angiography (MRA) and spiral computed tomography (CT) in 10 patients as well as ex vivo. Velocity mapping was performed in the suprarenal aorta and femoral arteries in 14 patients before and after stent-graft placement. For comparison it was also performed in six healthy volunteers. No ferromagnetism or heating was detected. Metal artifacts caused minimal image distortion on MRI/MRA. The artifacts disturbed image evaluation on CT at the graft bifurcation and graft limb junction. No significant differences in mean flow were found in patients before and after stent-graft placement. Our study indicates that MRI at 1.5 T may be performed safely in patients with the (Vanguard) stent-graft. MRI/MRA provides diagnostic image information. Velocity mapping is not included in our routine protocol.
  •  
5.
  •  
6.
  • Geijer, Bo, et al. (författare)
  • Persistent high signal on diffusion-weighted MRI in the late stages of small cortical and lacunar ischaemic lesions
  • 2001
  • Ingår i: Neuroradiology. - : Springer Science and Business Media LLC. - 1432-1920 .- 0028-3940. ; 43:2, s. 115-122
  • Tidskriftsartikel (refereegranskat)abstract
    • Diffusion-weighted imaging (DWI) is very sensitive to early brain infarcts. However, the late stages have been insufficiently studied. Infarcts in small vessel disease are often multiple and of different ages, and differentiation between new and old lesions might be difficult. We have therefore studied the change with time in DWI of small (< 3 ml) ischaemic lesions. We imaged 21 patients with an acute lacunar syndrome and a lesion visible on early DWI. They all had three MRI examinations 12-58 h (early), 7-16 and 54-144 days after the onset of stroke; 10 patients with high DWI signal on the third examination had a fourth examination 12-28 months after the stroke. MRI was performed at 1.5 T, using echo-planar DWI with 7 b-values from 0 to 1200 x 10(6) s/m2 and conventional T2-weighted imaging. After 7-16 days 18 of 21 lesions gave high signal on DWI, and 12/16 measurable lesions had a decreased apparent diffusion coefficient (ADC). After 54-144 days ten lesions still gave high DWI signal and two still had an ADC below normal. On the fourth examination there was no remaining high DWI signal and all ADC were higher than normal.
  •  
7.
  • Geijer, Bo, et al. (författare)
  • The value of b required to avoid T2 shine-through from old lucunar infarcts in diffusion-weighted imaging
  • 2001
  • Ingår i: Neuroradiology. - : Springer Science and Business Media LLC. - 1432-1920 .- 0028-3940. ; 43:7, s. 511-517
  • Tidskriftsartikel (refereegranskat)abstract
    • Multiple small infarcts of different ages are common in small-vessel disease. Diffusion-weighted imaging (DWI) is a powerful method for discriminating new from chronic lesions. This can be done on the diffusion-weighted images provided that b is sufficiently high. Our purpose was to determine that critical value of b. We reviewed DWI from a previous study of acute, mainly lacunar strokes, and selected 18 old lacunar infarcts, well defined on uncoded images with b 0 s/m2 (i. e., T2-weighted images) but invisible on DWI with b 1,200 x 10(6) s/m2. We used a 1.5 tesla imager and single-shot echo-planar technique. We had seven separate acquisitions with echo time 123 ms and b in steps between 0 and 1,200 x 10(6) s/m2. Two neuroradiologists blinded to the selection of lesions carried out two different lesion-detection procedures, thereby testing each lesion four times, giving a total of 72 tests of b values. The results were consistent, indicating a level for detection of 800 x 10(6) s/m2 in two tests, 400-600 x 10(6) s/m2 in 65 tests and at lower values in the remainder. For imagers up to 1.5 tesla, at long repetition times and an echo time up to 120 ms T2-shine through of old lacunar infarcts can be avoided using b of 1,000 x 10(6) s/m2.
  •  
8.
  • Holmqvist, Catarina, et al. (författare)
  • Collateral flow in coarctation of the aorta with magnetic resonance velocity mapping: correlation to morphological imaging of collateral vessels.
  • 2002
  • Ingår i: Journal of Magnetic Resonance Imaging. - : Wiley. - 1522-2586 .- 1053-1807. ; 15:1, s. 39-46
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: To correlate quantification of collateral flow in aortic coarctation with the morphological visualization of the collateral vessels and to compare different approaches to measurement of collateral flow. MATERIALS AND METHODS: Thirteen children with coarctation were examined with T1-weighted spin-echo (T1-W SE) imaging and 3D contrast-enhanced magnetic resonance angiography (MRA). MR velocity mapping was performed at four levels in the descending aorta. RESULTS: The flow immediately above and below the coarctation did not differ significantly. Measuring within the coarctation resulted in flow overestimation. The increase of flow from proximal to distal aorta was 12 +/- 21% in patients with no or uncertain collaterals and 69 +/- 55% in patients with pronounced collaterals. Spin-echo images and MRA were comparable in visualizing collateral vessels. The visual estimation of collaterals correlated reasonably well with flow quantification MR velocity mapping. CONCLUSION: Collateral flow assessment with MR velocity mapping is an accurate technique for evaluating the hemodynamic importance of a coarctation and is recommended if abundant collaterals are not visualized with spin echo or MRA.
  •  
9.
  •  
10.
  • Juul-Kristensen, Birgit, et al. (författare)
  • Muscle Sizes and Moment Arms of Rotator Cuff Muscles Determined by Magnetic Resonance Imaging
  • 2000
  • Ingår i: Cells Tissues Organs. - : S. Karger AG. - 1422-6405 .- 1422-6421. ; 167, s. 214-222
  • Tidskriftsartikel (refereegranskat)abstract
    • Biomechanical models which require information on, e.g., joint torque and muscle force are useful in the estimation of when and how mechanical overload of the musculoskeletal system may lead to disorders. The aim was to study the reliability and validity of magnetic resonance imaging (MRI) to quantify muscle sizes and moment arms by MRI and to test selected anthropometric measures as predictors of muscle sizes and moment arms. A total of 20 healthy Scandinavian women (age 22–58 years) participated in an MRI scanning of their dominant shoulder. With a PC-based program the reliability and the validity of the MRI measurements was estimated to be high, and mean anatomical cross-sectional areas (ACSA) and muscle lengths were measured to be 4.0, 9.8 and 12.1 cm2 and 12.0, 12.6 and 12.8 cm for m. supraspinatus, m. infraspinatus and m. subscapularis, respectively. Volumes were calculated to be 48.8, 125.1 and 153.6 cm3. Moment arms were measured with the upper arm in a neutral position and in a functional position of 34° abduction for m. supraspinatus only, and were 2.4 and 2.6 cm. Physiological cross-sectional area (PCSA) and its fiber force component were estimated from dissected fiber length and pennation angle. MRI volume and PCSA were 1.4–1.7 times higher than dissection data, primarily because of age differences. No external anthropometric measures were found to be predictors of volumes or moment arms.
  •  