1.
  • Bech, Martin, et al. (författare)
  • In-vivo dark-field and phase-contrast x-ray imaging.
  • 2013
  • Ingår i: Scientific Reports. - : Springer Science and Business Media LLC. - 2045-2322. ; 3:Nov 13
  • Tidskriftsartikel (refereegranskat)abstract
    • Novel radiography approaches based on the wave nature of x-rays when propagating through matter have a great potential for improved future x-ray diagnostics in the clinics. Here, we present a significant milestone in this imaging method: in-vivo multi-contrast x-ray imaging of a mouse using a compact scanner. Of particular interest is the enhanced contrast in regions related to the respiratory system, indicating a possible application in diagnosis of lung diseases (e.g. emphysema).
  •  
2.
  • Bech, Martin, et al. (författare)
  • Results from the first preclinical CT scanner with grating based phase contrast and a rotating gantry
  • 2012
  • Ingår i: International Workshop on X-Ray and Neutron Phase Imaging with Gratings. - : AIP. - 1551-7616 .- 0094-243X. - 9780735410725 ; 1466, s. 130-136
  • Konferensbidrag (refereegranskat)abstract
    • After successful demonstrations of soft-tissue phase-contrast imaging with grating interferometers at synchrotron radiation sources and at laboratory based x-ray tubes, a first preclinical CT scanner with grating based phase contrast imaging modality has been constructed. The rotating gantry is equipped with a three-grating interferometer, a 50 watt tungsten anode source and a Hamamatsu flat panel detector. The total length of the interferometer is 45 cm, and the bed of the scanner is optimized for mice, with a scanning diameter of 35 mm. From one single scan both phase-contrast and standard attenuation based tomography can be attained, providing an overall gain in image contrast.
  •  
3.
  • Fu, Jian, et al. (författare)
  • An algebraic iterative reconstruction technique for differential X-ray phase-contrast computed tomography
  • 2013
  • Ingår i: Zeitschrift für Medizinische Physik. - : Elsevier BV. - 1876-4436 .- 0939-3889. ; 23:3, s. 186-193
  • Tidskriftsartikel (refereegranskat)abstract
    • Iterative reconstruction has a wide spectrum of proven advantages in the field of conventional X-ray absorption-based computed tomography (CT). In this paper, we report on an algebraic iterative reconstruction technique for grating-based differential phase-contrast CT (DPC-CT). Due to the differential nature of DPC-CT projections, a differential operator and a smoothing operator are added to the iterative reconstruction, compared to the one commonly used for absorption-based CT data. This work comprises a numerical study of the algorithm and its experimental verification using a dataset measured at a two-grating interferometer setup. Since the algorithm is easy to implement and allows for the extension to various regularization possibilities, we expect a significant impact of the method for improving future medical and industrial DPC-CT applications.
  •  
4.
  • Fu, Jian, et al. (författare)
  • Helical differential X-ray phase-contrast computed tomography.
  • 2014
  • Ingår i: Physica Medica. - : Elsevier BV. - 1120-1797. ; 30:3, s. 374-379
  • Tidskriftsartikel (refereegranskat)abstract
    • We report on the first experimental results of helical differential phase-contrast computed tomography (helical DPC-CT) with a laboratory X-ray tube source and a Talbot-Lau grating interferometer. The results experimentally verify the feasibility of helical data acquisition and reconstruction in phase-contrast imaging, in analogy to its use in clinical CT systems. This allows fast and continuous volumetric scans for long objects with lengths exceeding the dimension of the detector. Since helical CT revolutionized the field of medical CT several years ago, we anticipate that this method will bring the same significant impact on the future medical and industrial applications of X-ray DPC-CT.
  •  
5.
  • Jensen, Torben Haugaard, et al. (författare)
  • Imaging of Metastatic Lymph Nodes by X-ray Phase-Contrast Micro-Tomography
  • 2013
  • Ingår i: PLoS ONE. - : Public Library of Science (PLoS). - 1932-6203. ; 8:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Invasive cancer causes a change in density in the affected tissue, which can be visualized by x-ray phase-contrast tomography. However, the diagnostic value of this method has so far not been investigated in detail. Therefore, the purpose of this study was, in a blinded manner, to investigate whether malignancy could be revealed by non-invasive x-ray phase-contrast tomography in lymph nodes from breast cancer patients. Seventeen formalin-fixed paraffin-embedded lymph nodes from 10 female patients (age range 37-83 years) diagnosed with invasive ductal carcinomas were analyzed by X-ray phase-contrast tomography. Ten lymph nodes had metastatic deposits and 7 were benign. The phase-contrast images were analyzed according to standards for conventional CT images looking for characteristics usually only visible by pathological examinations. Histopathology was used as reference. The result of this study was that the diagnostic sensitivity of the image analysis for detecting malignancy was 100% and the specificity was 87%. The positive predictive value was 91% for detecting malignancy and the negative predictive value was 100%. We conclude that x-ray phase-contrast imaging can accurately detect density variations to obtain information regarding lymph node involvement previously inaccessible with standard absorption x-ray imaging.
  •  
6.
  • Meinel, Felix G., et al. (författare)
  • Diagnosing and Mapping Pulmonary Emphysema on X-Ray Projection Images: Incremental Value of Grating-Based X-Ray Dark-Field Imaging
  • 2013
  • Ingår i: PLoS ONE. - : Public Library of Science (PLoS). - 1932-6203. ; 8:3
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To assess whether grating-based X-ray dark-field imaging can increase the sensitivity of X-ray projection images in the diagnosis of pulmonary emphysema and allow for a more accurate assessment of emphysema distribution. Materials and Methods: Lungs from three mice with pulmonary emphysema and three healthy mice were imaged ex vivo using a laser-driven compact synchrotron X-ray source. Median signal intensities of transmission (T), dark-field (V) and a combined parameter (normalized scatter) were compared between emphysema and control group. To determine the diagnostic value of each parameter in differentiating between healthy and emphysematous lung tissue, a receiver-operating-characteristic (ROC) curve analysis was performed both on a per-pixel and a per-individual basis. Parametric maps of emphysema distribution were generated using transmission, dark-field and normalized scatter signal and correlated with histopathology. Results: Transmission values relative to water were higher for emphysematous lungs than for control lungs (1.11 vs. 1.06, p<0.001). There was no difference in median dark-field signal intensities between both groups (0.66 vs. 0.66). Median normalized scatter was significantly lower in the emphysematous lungs compared to controls (4.9 vs. 10.8, p<0.001), and was the best parameter for differentiation of healthy vs. emphysematous lung tissue. In a per-pixel analysis, the area under the ROC curve (AUC) for the normalized scatter value was significantly higher than for transmission (0.86 vs. 0.78, p<0.001) and dark-field value (0.86 vs. 0.52, p<0.001) alone. Normalized scatter showed very high sensitivity for a wide range of specificity values (94% sensitivity at 75% specificity). Using the normalized scatter signal to display the regional distribution of emphysema provides color-coded parametric maps, which show the best correlation with histopathology. Conclusion: In a murine model, the complementary information provided by X-ray transmission and dark-field images adds incremental diagnostic value in detecting pulmonary emphysema and visualizing its regional distribution as compared to conventional X-ray projections.
  •  
7.
  •  
8.
  • Meinel, Felix G., et al. (författare)
  • Lung tumors on multimodal radiographs derived from grating-based X-ray imaging - A feasibility study
  • 2014
  • Ingår i: Physica Medica. - : Elsevier BV. - 1120-1797. ; 30:3, s. 352-357
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: The purpose of this study was to assess whether grating-based X-ray imaging may have a role in imaging of pulmonary nodules on radiographs. Materials and methods: A mouse lung containing multiple lung tumors was imaged using a small-animal scanner with a conventional X-ray source and a grating interferometer for phase-contrast imaging. We qualitatively compared the signal characteristics of lung nodules on transmission, dark-field and phase-contrast images. Furthermore, we quantitatively compared signal characteristics of lung tumors and the adjacent lung tissue and calculated the corresponding contrast-to-noise ratios. Results: Of the 5 tumors visualized on the transmission image, 3/5 tumors were clearly visualized and 1 tumor was faintly visualized in the dark-field image as areas of decreased small angle scattering. In the phase-contrast images, 3/5 tumors were clearly visualized, while the remaining 2 tumors were faintly visualized by the phase-shift occurring at their edges. No additional tumors were visualized in either the dark-field or phase-contrast images. Compared to the adjacent lung tissue, lung tumors were characterized by a significant decrease in transmission signal (median 0.86 vs. 0.91, p = 0.04) and increase in dark-field signal (median 0.71 vs. 0.65, p = 0.04). Median contrast-to-noise ratios for the visualization of lung nodules were 4.4 for transmission images and 1.7 for dark-field images (p = 0.04). Conclusion: Lung nodules can be visualized on all three radiograph modalities derived from grating-based X-ray imaging. However, our initial data suggest that grating-based multimodal X-ray imaging does not increase the sensitivity of chest radiographs for the detection of lung nodules. (C) 2013 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
  •  
9.
  • Mohajerani, Pouyan, et al. (författare)
  • FMT-PCCT: Hybrid Fluorescence Molecular Tomography-X-Ray Phase-Contrast CT Imaging of Mouse Models
  • 2014
  • Ingår i: IEEE Transactions on Medical Imaging. - 1558-254X. ; 33:7, s. 1434-1446
  • Tidskriftsartikel (refereegranskat)abstract
    • The implementation of hybrid fluorescencemolecular tomography (FMT) and X-ray computed tomography (CT) has been shown to be a necessary development, not only for combining anatomical with functional and molecular contrast, but also for generating optical images of high accuracy. FMT affords highly sensitive 3-D imaging of fluorescence bio-distribution, but in stand-alone form it offers images of low resolution. It was shown that FMT accuracy significantly improves by considering anatomical priors from CT. Conversely, CT generally suffers from low soft tissue contrast. Therefore utilization of CT data as prior information in FMT inversion is challenging when different internal organs are not clearly differentiated. Instead, we combined herein FMT with emerging X-ray phase-contrast CT (PCCT). PCCT relies on phase shift differences in tissue to achieve soft tissue contrast superior to conventional CT. We demonstrate for the first time FMT-PCCT imaging of different animal models, where FMT and PCCT scans were performed in vivo and ex vivo, respectively. The results show that FMT-PCCT expands the potential of FMT in imaging lesions with otherwise low or no CT contrast, while retaining the cost benefits of CT and simplicity of hybrid device realizations. The results point to the most accurate FMT performance to date.
  •  
10.
  • Schleede, Simone, et al. (författare)
  • Emphysema diagnosis using X-ray dark-field imaging at a laser-driven compact synchrotron light source
  • 2012
  • Ingår i: Proceedings of the National Academy of Sciences. - : Proceedings of the National Academy of Sciences. - 1091-6490 .- 0027-8424. ; 109:44, s. 17880-17885
  • Tidskriftsartikel (refereegranskat)abstract
    • In early stages of various pulmonary diseases, such as emphysema and fibrosis, the change in X-ray attenuation is not detectable with absorption-based radiography. To monitor the morphological changes that the alveoli network undergoes in the progression of these diseases, we propose using the dark-field signal, which is related to small-angle scattering in the sample. Combined with the absorption-based image, the dark-field signal enables better discrimination between healthy and emphysematous lung tissue in a mouse model. All measurements have been performed at 36 keV using a monochromatic laser-driven miniature synchrotron X-ray source (Compact Light Source). In this paper we present grating-based dark-field images of emphysematous vs. healthy lung tissue, where the strong dependence of the dark-field signal on mean alveolar size leads to improved diagnosis of emphysema in lung radiographs.
  •  