SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "hsv:(MEDICIN OCH HÄLSOVETENSKAP) hsv:(Medicinsk bioteknologi) ;pers:(Nilsson Bo)"

Sökning: hsv:(MEDICIN OCH HÄLSOVETENSKAP) hsv:(Medicinsk bioteknologi) > Nilsson Bo

  • Resultat 1-10 av 24
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Asif, Sana, et al. (författare)
  • Heparinization of cell surfaces with short peptide-conjugated PEG-lipid regulates thromboinflammation in transplantation of human MSCs and hepatocytes
  • 2016
  • Ingår i: Acta Biomaterialia. - : Elsevier BV. - 1742-7061 .- 1878-7568. ; 35, s. 194-205
  • Tidskriftsartikel (refereegranskat)abstract
    • Infusion of therapeutic cells into humans is associated with immune responses, including thromboinflammation, which result in a large loss of transplanted cells\ To address these problems, heparinization of the cell surfaces was achieved by a cell-surface modification technique using polyethylene glycol conjugated phospholipid (PEG-lipid) derivatives. A short heparin-binding peptide was conjugated to the PEG-lipid for immobilization of heparin conjugates on the surface of human mesenchymal stem cells (hMSCs) and human hepatocytes. Here three kinds of heparin-binding peptides were used for immobilizing heparin conjugates and examined for the antithrombogenic effects on the cell surface. The heparinized cells were incubated in human whole blood to evaluate their hemocompatibility by measuring blood parameters such as platelet count, coagulation markers, complement markers, and Factor Xa activity. We found that one of the heparin-binding peptides did not show cytotoxicity after the immobilization with heparin conjugates. The degree of binding of the heparin conjugates on the cell surface (analyzed by flow cytometer) depended on the ratio of the active peptide to control peptide. For both human MSCs and hepatocytes in whole-blood experiments, no platelet aggregation was seen in the heparin conjugate-immobilized cell group vs. the controls (non-coated cells or control peptide). Also, the levels of thrombin-antithrombin complex (TAT), C3a, and sC5b-9 were significantly lower than those of the controls, indicating a lower activation of coagulation and complement. Factor Xa analysis indicated that the heparin conjugate was still active on the cell surface at 24 h post-coating. It is possible to immobilize heparin conjugates onto hMSC and human hepatocyte surfaces and thereby protect the cell surfaces from damaging thromboinflammation. Statement of Signigficance We present a promising approach to enhance the biocompatibility of therapeutic cells. Here we used short peptide-conjugated PEG-lipid for cell surface modification and heparin conjugates for the coating of human hepatocytes and MSCs. We screened the short peptides to find higher affinity for heparinization of cell surface and performed hemocompatibility assay of heparinized human hepatocytes and human MSCs in human whole blood. Using heparin-binding peptide with higher affinity, not only coagulation activation but also complement activation was significantly suppressed. Thus, it was possible to protect human hepatocytes and human MSCs from the attack of thromboinflammatory activation, which can contribute to the improvement graft survival. (C) 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
  •  
2.
  • Asif, Sana, M.D, PhD student, et al. (författare)
  • Validation of an MPC polymer coating to attenuate surface- induced cross-talk between the complement and coagulation systems in whole blood in in vitro and in vivo models
  • 2019
  • Ingår i: Macromolecular Bioscience. - : Wiley-VCH Verlagsgesellschaft. - 1616-5187 .- 1616-5195. ; 19:5
  • Tidskriftsartikel (refereegranskat)abstract
    • Artificial surfaces that come into contact with blood induce an immediate activation of the cascade systems of the blood, leading to a thrombotic and/or inflammatory response that can eventually cause damage to the biomaterial or the patient, or to both. Heparin coating has been used to improve hemocompatibility, and another approach is 2-methacryloyloxyethyl phosphorylcholine (MPC)-based polymer coatings. Here, the aim is to evaluate the hemocompatibility of MPC polymer coating by studying the interactions with coagulation and complement systems using human blood in vitro model and pig in vivo model. The stability of the coatings is investigated in vitro and MPC polymer-coated catheters are tested in vivo by insertion into the external jugular vein of pigs to monitor the catheters' antithrombotic properties. There is no significant activation of platelets or of the coagulation and complement systems in the MPC polymer-coated one, which was superior in hemocompatibility to non-coated matrix surfaces. The protective effect of the MPC polymer coat does not decline after incubation in human plasma for up to 2 weeks. With MPC polymer-coated catheters, it is possible to easily draw blood from pig for 4 days in contrast to the case for non-coated catheters, in which substantial clotting is seen.
  •  
3.
  • Huang, Shan, et al. (författare)
  • Reciprocal relationship between contact and complement system activation on artificial polymers exposed to whole human blood.
  • 2016
  • Ingår i: Biomaterials. - : Elsevier. - 0142-9612 .- 1878-5905. ; 77, s. 111-119
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Inappropriate and uncontrolled activation of the cascade systems in the blood is a driving force in adverse inflammatory and thrombotic reactions elicited by biomaterials, but limited data are available on the activation of the contact system by polymers and the present study was undertaken to investigate these mechanisms in established models.METHODS: Polymer particles were incubated in (1) EDTA-plasma (10 mM) to monitor the adsorption of 20 selected proteins; (2) lepirudin-anticoagulated plasma to evaluate contact system activation, monitored by the formation of complexes between the generated proteases factor[F]XIIa, FXIa and kallikrein and the serpins C1-inhibitor [C1INH] and antithrombin [AT]; (3) lepirudin-anticoagulated whole blood to determine cytokine release.RESULTS: Strong negative correlations were found between 10 cytokines and the ratio of deposited FXII/C1INH, generated FXIIa-C1INH complexes, and kallikrein-C1INH complexes. Formation of FXIIa-C1INH complexes correlated negatively with the amount of C3a and positively with deposited IgG.CONCLUSIONS: A reciprocal relationship was found between activation of the contact system and the complement system induced by the polymers studied here. The ratios of FXII/C1INH or C4/C4BP, adsorbed from EDTA-plasma are useful surrogate markers for cytokine release and inflammatory response to materials intended for blood contact.
  •  
4.
  • Nilsson Ekdahl, Kristina, et al. (författare)
  • Evaluation of the blood compatibility of materials, cells and tissues: Basic concepts, test models and practical guidelines
  • 2013
  • Ingår i: Complement Therapeutics. - Boston, MA : Springer. - 9781461441175 - 9781461441182 ; 735, s. 257-270
  • Bokkapitel (refereegranskat)abstract
    • Medicine today uses a wide range of biomaterials, most of which make contact with blood permanently or transiently upon implantation. Contact between blood and nonbiological materials or cells or tissue of nonhematologic origin initiates activation of the cascade systems (complement, contact activation/coagulation) of the blood, which induces platelet and leukocyte activation.Although substantial progress regarding biocompatibility has been made, many materials and medical treatment procedures are still associated with severe side effects. Therefore, there is a great need for adequate models and guidelines for evaluating the blood compatibility of biomaterials. Due to the substantial amount of cross talk between the different cascade systems and cell populations in the blood, it is advisable to use an intact system for evaluation.Here, we describe three such in vitro models for the evaluation of the biocompatibility of materials and therapeutic cells and tissues. The use of different anticoagulants and specific inhibitors in order to be able to dissect interactions between the different cascade systems and cells of the blood is discussed. In addition, we describe two clinically relevant medical treatment modalities, the integration of titanium implants and transplantation of islets of Langerhans to patients with type 1 diabetes, whose mechanisms of action we have addressed using these in vitro models.
  •  
5.
  • Nilsson Ekdahl, Kristina, et al. (författare)
  • Therapeutic regulation of complement activation in extracorporeal circuits and intravascular treatments with special reference to the alternative pathway amplification loop
  • 2023
  • Ingår i: Immunological Reviews. - : John Wiley & Sons. - 0105-2896 .- 1600-065X. ; 313:1, s. 91-103
  • Tidskriftsartikel (refereegranskat)abstract
    • A number of clinical treatment modalities involve contact between blood and biomaterials: these include extracorporeal circuits such as hemodialysis, cardiopulmonary bypass, plasmapheresis, and intravascular treatments. Common side effects arising from these treatments are caused by activation of the cascade systems of the blood. Many of these side effects are mediated via the complement system, including thromboinflammatory reactions and rejection of implants. Depending on the composition of the materials, complement activation is triggered via all the activation pathways but is by far mostly driven by the alternative pathway amplification loop. On biomaterial surfaces the alternative pathway amplification is totally unregulated and leads under optimal conditions to deposition of complement fragments, mostly C3b, on the surface leading to a total masking of the underlying surface. In this review, we discuss the mechanism of the complement activation, clinical consequences of the activation, and potential strategies for therapeutic regulation of the activation, using hemodialysis as demonstrator.
  •  
6.
  • Rangasami, Vignesh K., et al. (författare)
  • Pluronic Micelle-Mediated Tissue Factor Silencing Enhances Hemocompatibility, Stemness, Differentiation Potential, and Paracrine Signaling of Mesenchymal Stem Cells
  • 2021
  • Ingår i: Biomacromolecules. - : American Chemical Society (ACS). - 1525-7797 .- 1526-4602. ; 22:5, s. 1980-1989
  • Tidskriftsartikel (refereegranskat)abstract
    • Mesenchymal stem/stromal cells (MSCs) evoke great excitement for treating different human diseases due to their ability to home inflamed tissues, suppress inflammation, and promote tissue regeneration. Despite great promises, clinical trial results are disappointing as allotransplantation of MSCs trigger thrombotic activity and are damaged by the complement system, compromising their survival and function. To overcome this, a new strategy is presented by the silencing of tissue factor (TF), a transmembrane protein that mediates procoagulant activity. Novel Pluronic-based micelles are designed with the pendant pyridyl disulfide group, which are used to conjugate TF-targeting siRNA by the thiol-exchange reaction. This nanocarrier design effectively delivered the payload to MSCs resulting in similar to 72% TF knockdown (KD) without significant cytotoxicity. Hematological evaluation of MSCs and TF-KD MSCs in an ex vivo human whole blood model revealed a significant reduction in an instant-blood-mediated-inflammatory reaction as evidenced by reduced platelet aggregation (93% of free platelets in the TF-KD group, compared to 22% in untreated bone marrow-derived MSCs) and thrombin- antithrombin complex formation. Effective TF silencing induced higher MSC differentiation in osteogenic and adipogenic media and showed stronger paracrine suppression of proinflammatory cytokines in macrophages and higher stimulation in the presence of endotoxins. Thus, TF silencing can produce functional cells with higher fidelity, efficacy, and functions.
  •  
7.
  •  
8.
  • Moll, Guido, et al. (författare)
  • Do Cryopreserved Mesenchymal Stromal Cells Display Impaired Immunomodulatory and Therapeutic Properties?
  • 2014
  • Ingår i: Stem Cells. - : Oxford University Press (OUP). - 1066-5099 .- 1549-4918. ; 32:9, s. 2430-2442
  • Tidskriftsartikel (refereegranskat)abstract
    • We have recently reported that therapeutic mesenchymal stromal cells (MSCs) have low engraftment and trigger the instant blood mediated inflammatory reaction (IBMIR) after systemic delivery to patients, resulting in compromised cell function. In order to optimize the product, we compared the immunomodulatory, blood regulatory, and therapeutic properties of freeze-thawed and freshly harvested cells. We found that freeze-thawed MSCs, as opposed to cells harvested from continuous cultures, have impaired immunomodulatory and blood regulatory properties. Freeze-thawed MSCs demonstrated reduced responsiveness to proinflammatory stimuli, an impaired production of anti-inflammatory mediators, increased triggering of the IBMIR, and a strong activation of the complement cascade compared to fresh cells. This resulted in twice the efficiency in lysis of thawed MSCs after 1 hour of serum exposure. We found a 50% and 80% reduction in viable cells with freshly detached as opposed to thawed in vitro cells, indicating a small benefit for fresh cells. In evaluation of clinical response, we report a trend that fresh cells, and cells of low passage, demonstrate improved clinical outcome. Patients treated with freshly harvested cells in low passage had a 100% response rate, twice the response rate of 50% observed in a comparable group of patients treated with freeze-thawed cells at higher passage. We conclude that cryobanked MSCs have reduced immunomodulatory and blood regulatory properties directly after thawing, resulting in faster complement-mediated elimination after blood exposure. These changes seem to be paired by differences in therapeutic efficacy in treatment of immune ailments after hematopoietic stem cell transplantation.
  •  
9.
  • Asawa, Kenta, et al. (författare)
  • Cell Surface Functionalization with Heparin-Conjugated Lipid to Suppress Blood Activation
  • 2021
  • Ingår i: Advanced Functional Materials. - : John Wiley & Sons. - 1616-301X .- 1616-3028. ; 31:11
  • Tidskriftsartikel (refereegranskat)abstract
    • Organ transplantation leads to damage of the endothelial glycocalyx of the transplanted organ, and the activated endothelial surface induces thromboinflammation. The result is dysfunction of the transplanted organ, known as ischemia reperfusion injury (IRI). Long-term graft survival strongly depends on the regulation of IRI. Here the aim is to reconstruct the glycocalyx to regulate blood activation during IRI. Heparin-conjugated lipid (fHep-lipid) is synthesized with 0.6, 1.8, 2.7, 4.5, or 8.0 fragmented heparins per lipid to compare their anticoagulation activity. First, liposome and cells are modified with each fHep-lipid and the surface properties are evaluated. Then the hemocompatibility of the modified human mesenchymal stem cells (hMSCs) is examined in a loop model using human blood. The antithrombin-binding capacity and anti-factor Xa activity of the fHep-lipids depend on the number of conjugated heparins, with efficacy increasing with increasing number of heparins. The modified liposomes are highly negatively charged and show strong anti-factor Xa activity. In addition, the cell surfaces of human erythrocytes and hMSCs can be uniformly modified with fHep-lipid. The whole blood studies reveal that fHep-lipid on hMSCs can prevent generation of thrombin-antithrombin complexes, coagulation markers, and platelet aggregation, whereas unmodified hMSCs trigger activation of the platelet and coagulation systems.
  •  
10.
  • Duehrkop, Claudia, et al. (författare)
  • Development and characterization of an innovative heparin coating to stabilize and protect liposomes against adverse immune reactions
  • 2016
  • Ingår i: Colloids and Surfaces B. - : Elsevier BV. - 0927-7765 .- 1873-4367. ; 141, s. 576-583
  • Tidskriftsartikel (refereegranskat)abstract
    • Liposomes have been recognized as excellent drug delivery systems, but when they come in direct contact with different blood components they may trigger an immediate activation of the innate immune system. The aim of the present study was to produce long-circulating, blood-compatible liposomes by developing a construct of liposomes covered by a novel unique heparin complex (CHC; 70 heparin molecules per complex) to avoid recognition by the innate immune system. Unilamellar, cationic liposomes were produced by hand extrusion through a 100-nm polycarbonate membrane. Coating of liposomes with the macromolecular CHC was accomplished by electrostatic interactions. Dynamic light scattering as well as QCM-D measurements were used to verify the electrostatic deposition of the negatively charged CHC to cationic liposomes. The CHC-coated liposomes did not aggregate when in contact with lepirudin anti coagulated plasma. Unlike previous attempts to coat liposomes with heparin, this technique produced freely moveable heparin strands sticking out from the liposome surface, which exposed AT binding sites reflecting the anticoagulant potentials of the liposomes. In experiments using lepirudin-anticoagulated plasma, CHC-coated liposomes, in contrast to non-coated control liposomes, did not activate the complement system, as evidenced by low C3a and sC5b-9 generation and reduced leakage from the liposomes. In conclusion, we show that liposomes can be successfully coated with the biopolymer CHC, resulting in biocompatible and stable liposomes that have significant application potential. (C) 2016 Elsevier B.V. All rights reserved.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 24
Typ av publikation
tidskriftsartikel (22)
annan publikation (1)
bokkapitel (1)
Typ av innehåll
refereegranskat (23)
övrigt vetenskapligt/konstnärligt (1)
Författare/redaktör
Nilsson Ekdahl, Kris ... (21)
Teramura, Yuji (10)
Fromell, Karin (7)
Asawa, Kenta (4)
Ishihara, Kazuhiko (3)
visa fler...
Sandholm, Kerstin (3)
Le Blanc, Katarina (3)
Larsson, Rolf (2)
Nicholls, Ian A. (2)
Seisenbaeva, Gulaim (2)
Kessler, Vadim (2)
Lambris, John D. (2)
Huber-Lang, Markus (2)
Nilsson, Per H. (2)
Mollnes, Tom Eirik (2)
Barbu, Andreea (2)
Korsgren, Olle (1)
Bucht, Anders (1)
Edwards, Katarina (1)
Wennerberg, Ann, 195 ... (1)
Manivel, Vivek Anand (1)
Inoue, Yuuki (1)
Leneweit, Gero (1)
Sato, Yuya (1)
Thomsen, Peter, 1953 (1)
Ringden, Olle (1)
Ekstrand-Hammarström ... (1)
Chung, Ung-Il (1)
Hilborn, Jöns, 1956- (1)
Davoodpour, Padideh (1)
Grinnemo, Karl-Henri ... (1)
Norda, Rut (1)
Sanchez, Javier (1)
Elgue, Graciela (1)
Jensen Waern, Marian ... (1)
Gustafson, Elisabet (1)
Schött, Ulf (1)
Fredriksson, Fanny, ... (1)
Lindell, Björn (1)
Thor, Andreas (1)
Engstrand, Thomas (1)
Rasmusson, Lars, 196 ... (1)
Asif, Sana (1)
Jonsson, Nina (1)
Asif, Sana, M.D, PhD ... (1)
Magnusson, Peetra U. (1)
Yuuki, Inoue (1)
Holmgren, Robin (1)
Rydén, Anneli (1)
visa färre...
Lärosäte
Uppsala universitet (24)
Linnéuniversitetet (20)
Karolinska Institutet (3)
Sveriges Lantbruksuniversitet (3)
Umeå universitet (2)
Göteborgs universitet (1)
visa fler...
Lunds universitet (1)
visa färre...
Språk
Engelska (24)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (24)
Naturvetenskap (13)
Teknik (1)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy