SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "hsv:(MEDICIN OCH HÄLSOVETENSKAP) hsv:(Medicinsk bioteknologi) hsv:(Annan medicinsk bioteknologi) ;pers:(Banaś Dariusz)"

Sökning: hsv:(MEDICIN OCH HÄLSOVETENSKAP) hsv:(Medicinsk bioteknologi) hsv:(Annan medicinsk bioteknologi) > Banaś Dariusz

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Czub, Joanna, et al. (författare)
  • Biological effects of mixed-ion beams. Part 1 : Effect of irradiation of the CHO-K1 cells with a mixed-ion beam containing the carbon and oxygen ions
  • 2018
  • Ingår i: Applied Radiation and Isotopes. - : Elsevier BV. - 0969-8043 .- 1872-9800. ; 139, s. 304-309
  • Tidskriftsartikel (refereegranskat)abstract
    • Carbon and oxygen ions were accelerated simultaneously to estimate the effect of irradiation of living cells with the two different ions. This mixed ion beam was used to irradiate the CHO-K1 cells, and a survival test was performed. The type of the effect of the mixed ion beam on the cells was determined with the isobologram method, whereby survival curves for irradiations with individual ion beams were also used. An additive effect of irradiation with the two ions was found.
  •  
2.
  • Czub, Joanna, et al. (författare)
  • Biological effects of mixed-ion beams. Part 2 : The relative biological effectiveness of CHO-K1 cells irradiated by mixed- and single-ion beams
  • 2019
  • Ingår i: Applied Radiation and Isotopes. - : Elsevier BV. - 0969-8043 .- 1872-9800. ; 150, s. 192-198
  • Tidskriftsartikel (refereegranskat)abstract
    • The relative biological effectiveness (RBE) values were determined for single- and mixed-ion beams containing carbon and oxygen ions. The CHO-K1 cells were irradiated with beams with the linear energy transfer (LET) values of 236-300 and 461-470 keV/mu m for C-12 and O-16 ions, respectively. The RBE was estimated as a function of dose, survival fraction (SF) and LET. The SF was not affected by varying contributions of the constituent ions to the total mixed dose. The RBE has the same value for single-ion exposures with ions with LET 300 (C-12) and 470 keV/mu m (O-16).
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy