1.
  • Buendia, Ruben, 1982, et al. (författare)
  • Estimation of body fluids with bioimpedance spectroscopy: state of the art methods and proposal of novel methods
  • 2015
  • Ingår i: Physiological Measurement. - : IOP Publishing. - 0967-3334 .- 1361-6579. ; 36:10
  • Tidskriftsartikel (refereegranskat)abstract
    • Determination of body fluids is a useful common practice in determination of disease mechanisms and treatments. Bioimpedance spectroscopy (BIS) methods are non-invasive, inexpensive and rapid alternatives to reference methods such as tracer dilution. However, they are indirect and their robustness and validity are unclear. In this article, state of the art methods are reviewed, their drawbacks identified and new methods are proposed. All methods were tested on a clinical database of patients receiving growth hormone replacement therapy. Results indicated that most BIS methods are similarly accurate (e.g. < 0.5 +/- 3.0% mean percentage difference for total body water) for estimation of body fluids. A new model for calculation is proposed that performs equally well for all fluid compartments (total body water, extra-and intracellular water). It is suggested that the main source of error in extracellular water estimation is due to anisotropy, in total body water estimation to the uncertainty associated with intracellular resistivity and in determination of intracellular water a combination of both.
  •  
2.
  • Ferreira, Javier, 1982-, et al. (författare)
  • AD5933-based Spectrometer for Electrical Bioimpedance Applications
  • 2010
  • Ingår i: Journal of Physics: Conference Series. - : IOP Publishing. - 1742-6596. ; 224:1, s. 012011-
  • Konferensbidrag (refereegranskat)abstract
    • o build an Electrical Bioimpedance (EBI) spectrometer using the Impedance Measurement System-On-Chip AD5933 together with a 4-Electrode Analog Front End (4E-AFE) has been proven practicable. Such small measurement devices can make possible several new applications of EBI technology, especially when combined with functional textiles, which can enable wearable applications for personal health and home monitoring. After the implementation and functional validation of the 4E-AFE-enabled spectrometer, the next natural step is to validate for which EBI applications the 4E-AFE-enabled system is suitable. To test the applicability of this novel spectrometer on several EBI applications, 2R1C equivalent models have been experimentally obtained and impedance spectroscopy measurements have been performed with the system under study and with the SFB7 EBI spectrometer manufactured by ImpediMed. The 2R1C circuit parameters have been estimated with the BioImp software from the spectra obtained with both EBI spectrometers and the estimated values have been compared with the original values used in each circuit model implementation. The obtained results indicated that the 4E-AFE-enabled system cannot beat the performance of the SFB7 in accuracy but it performs better in preciseness. In any case the overall performance indicates that the 4E-AFE-enabled system can perform spectroscopy measurements in the frequency range from 5 to 100 kHz.
  •  