SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "hsv:(TEKNIK OCH TEKNOLOGIER) hsv:(Annan teknik) ;pers:(Thottappillil Rajeev)"

Sökning: hsv:(TEKNIK OCH TEKNOLOGIER) hsv:(Annan teknik) > Thottappillil Rajeev

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Månsson, Daniel, 1979- (författare)
  • Intentional electromagnetic interference (IEMI) : Susceptibility investigations and classification of civilian systems and equipment
  • 2008
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • This PhD thesis addresses the threat posed to society by sources that can produce high power electromagnetic pulses (HEPM) and be used maliciously to disturb or damage electronic equipment. The vulnerability from intentional electromagnetic interference (IEMI) has increased in the recent decades due to the widespread dependence of the civil society on sensitive electronic systems and proliferation of radiation sources. As the characteristics of the disturbances associated with IEMI often have very high frequency content, the existing mitigation measures and protection components may not be adequate. It was seen that for ultra wideband (UWB) transients low voltage protection components may not work as intended, due to parasitic components that arises from the packaging of the device. The large spatial distribution of many civilian facilities and critical infra-structures (e.g., power generation, communications, train system, etc.) presents many unexpected ports for an attacker as the majority of the parts of these systems are not protected or secure. As the new European Rail Traffic Management System (ERTMS) will utilize wireless communication for communication and control of the trains the vulnerability from different radiating HPEM sources was investigated. Angles of incidence and frequencies that are a threat in a given situation are identified. Due to the possibility of unexpected ports, the propagation of differential mode ultra wideband transients in low voltage power networks, when injected into a power socket of a facility, was studied. The effects on the transient propagation from cable bends, switches and junctions were studied, both in a laboratory setup and in the network of a facility. Also, as modern electronic equipment and systems may not be tested for waveforms and disturbances other than standardized EMC tests, experiments on some common commercial-off-the-shelf (COTS) equipment were performed with non-standard test situation. It was seen that these could easily be disturbed or even permanently damaged. In addition, due to the inherent difficulties with IEMI, a new method for classifying facilities from IEMI is suggested. It is based on available terminology of accessibility (A), susceptibility (S) and consequence (C), but expands these and forms the so called IEMI/ASC-cube.
  •  
2.
  • Theethayi, Nelson, et al. (författare)
  • A theoretical study on the consequence of a direct lightning strike to electrified railway system in Sweden
  • 2005
  • Ingår i: Electric Power System Research. - : Elsevier BV. ; 74:2, s. 267-280
  • Tidskriftsartikel (refereegranskat)abstract
    • Direct lightning strike to a single-track electrified railway system in Sweden is modeled in this paper. Using this model, the induced voltages in each of the nine conductors at heights varying from 0.5 m (tracks) to 10 m above the ground are estimated. The effect of the finitely conducting ground is included using a time domain expression for the transient ground impedance that has better early time and late time behavior. The main interconnection between the conductors and the flashover strength of the supporting insulators is included in the simulations. A simple model for the arc channel during flashover of the insulators and the ionization of the soil around the pole foundations is also included in the model to assess the possible realistic surge voltage distribution in the system. It is shown in the paper that finite ground conductivity, interconnections between the conductors, arcing phenomena of insulation flashover and grounding of the poles decide the voltage/current distribution in the conductors. Simulations have been also carried out to determine the voltages on the lines and across the rails as function of distance from the point of strike as it could be a necessary data for deciding the possible future protection schemes. It was found that for a lightning stroke of 31 kA peak, large common mode and differential mode surges exist on the lines which could create excessive voltages between the line and neutral of the transformer and might pose a threat to the various low voltage equipments used for telecommunication, signaling and control.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy