1.
  • Rattfält, Linda, 1979-, et al. (författare)
  • Robust heartbeat detector based on weighted correlation and multichannel input : Implementation on the ECG recorded with textile electrodes
  • 2013
  • Ingår i: International Journal of E-Health and Medical Communications. - : IGI Global. - 1947-315X .- 1947-3168. ; 4:1, s. 61-71
  • Tidskriftsartikel (refereegranskat)abstract
    • The aim of this study was to develop and evaluate a robust heartbeat detector for noisy electrocardiograms (ECGs) recorded with textile electrodes. The authors suggest a method based on weighted correlation in a multi-channel ECG to obtain a heartbeat detector. Signals were acquired during rest and at movements which simulate every day activities. From each recording a segment corresponding to a heartbeat was extracted and correlated with the whole signal. From the correlation data, heartbeat candidates were derived and weighted based on their variance similarity with the heartbeat model and previous heartbeats. Finally, the outputs of each channel were added to create the global output. The output was compared to the Pan Tompkins heartbeat detector. Results are promising for recordings at rest (sensitivity = 0.97, positive predictive value (PPV) = 0.97). For static muscle tension in the torso the results were much higher than the reference method (sensitivity = 0.77, PPV = 0.85). Corresponding values for the reference method were sensitivity = 0.96 and PPV = 0.95 at rest and sensitivity = 0.52 and PPV = 0.75 during muscle tension.
  •  
2.
  • Rattfält, Linda, 1979- (författare)
  • Smartware electrodes for ECG measurements : Design, evaluation and signal processing
  • 2013
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • The aim of this thesis work has been to study textile and screen printed smartware electrodes for electrocardiographic (ECG) measurements both in terms of their electrode properties and possibility to further improve their robustness to movement induced noise by using signal processing. Smartware electrodes for ECG measurements have previously been used in various applications but basic electrical electrode properties have not sufficiently been looked into. Furthermore, we believe that there is a possibility to reduce disturbances in the smartware ECG by adding redundant sensors and applying sensor fusion signal processing.Electrical properties of conductive textiles have been evaluated in terms of stability and electrode impedance. Three yarns and textile electrode surfaces were tested. The electrodes made from pure stainless steel and 50\% stainless steel/ 50\% polyester showed acceptable stability of electrode potentials. All electrode measurements were performed on skin.Furthermore, we produced six screen printed electrodes and their electrical performance was investigated in an electrochemical cell. The tested inks contained carbon or silver particles in the conduction lines, and Ag/AgCl particles in the electrode surface. Results show that all electrodes were stable in time, with a maximum drift of a few mV during 30 minutes. The silver ink is superior to the carbon based in terms of electrode impedance at the higher frequencies.To extract viable physiological information from noisy signals, canonical correlation analysis (CCA) was applied on multi-channel ECG signals recorded with textile electrodes. Using CCA to solve the blind source separation (BSS) problem, we intended to separate the ECG signal from the various noise sources. The method (CCABSS) was compared to averaging of the ECG channels and to the independent component analysis method (ICA). In the dataset consisting of noisy ECG recordings, the signal was uninterpretable in 7% after CCABSS. Corresponding values for averaging and ICA were 33% and 17%, respectively.Smartware applications often include heartbeat detection while moving, a measurement situation which is prone to produce noise corrupted ECG signals. To compensate for this, we used an event detector based on a multi-channel input, a model of the event and weighted correlation. For measurements at rest and static muscle tension, the sensitivity of the event detector was 97% and 77% respectively. Corresponding values for the golden standard detector Pan-Tompkins were 96% and 52%, respectively. 
  •  
3.
  •  
4.
  •  
5.
  • Ask, Per (författare)
  • Measurement techniques for urodynamic investigations.
  • 1989
  • Ingår i: Critical reviews in biomedical engineering. - 0278-940X .- 1943-619X. ; 17:5, s. 413-449
  • Tidskriftsartikel (refereegranskat)abstract
    • Important measurement techniques for investigating lower urinary tract function are flow and pressure measurements. The demands on urinary flowmeters and the measurement principles of balance type, rotating disc, dipstick, and air-displacement type are described. Urological pressure measurements are performed in the bladder, in the urethra, and in the abdominal cavity. Various fluid-filled and microtransducer systems are reviewed and demands for performance given. Differences in measuring a mechanical pressure, like in the urethra, and a fluid pressure in the bladder are discussed. Electromyography (EMG) technique is used to investigate various neurological disturbances in the lower urinary tract. The electrode technique is also described. Furthermore, techniques for incontinence detection are reviewed.
  •  
6.
  • Ask, Per, et al. (författare)
  • NovaMedTech - A regional program for supporting new medical technologies in personalized health care
  • 2012
  • Ingår i: Studies in Health Technology and Informatics. - 9781614990680 ; 177, s. 71-5
  • Konferensbidrag (refereegranskat)abstract
    • NovaMedTech is an initiative funded from EU structural funds for supporting new medical technologies for personalized health care. It aims at bringing these technologies into clinical use and to the health care market. The program has participants from health care, industry and academia in East middle Sweden. The first three year period of the program was successful in terms of product concepts tried clinically, and number of products brought to a commercialization phase. Further, the program has led to a large number of scientific publications. Among projects supported, we can mention: Intelligent sensor networks; A digital pen to collect medical information about health status from patients; A web-based intelligent stethoscope; Methodologies to measure local blood flow and nutrition using optical techniques; Blood flow assessment from ankle pressure measurements; Technologies for pressure ulcer prevention; An IR thermometer for improved accuracy; A technique that identifies individuals prone to commit suicide among depressed patients; Detection of infectious disease using an electronic nose; Identification of the lactate threshold from breath; Obesity measurements using special software and MR camera; and An optical probe guided tumor resection. During the present three years period emphasis will be on entrepreneurial activities supporting the commercialization and bringing products to the market.
  •  
7.
  •  
8.
  •  
9.
  •  
10.
  • Gharehbaghi, Arash, et al. (författare)
  • A novel method for discrimination between innocent and pathological heart murmurs
  • 2015
  • Ingår i: Medical Engineering and Physics. - : Elsevier. - 1350-4533 .- 1873-4030. ; 37:7, s. 674-682
  • Tidskriftsartikel (refereegranskat)abstract
    • This paper presents a novel method for discrimination between innocent and pathological murmurs using the growing time support vector machine (GTSVM). The proposed method is tailored for characterizing innocent murmurs (IM) by putting more emphasis on the early parts of the signal as IMs are often heard in early systolic phase. Individuals with mild to severe aortic stenosis (AS) and IM are the two groups subjected to analysis, taking the normal individuals with no murmur (NM) as the control group. The AS is selected due to the similarity of its murmur to IM, particularly in mild cases. To investigate the effect of the growing time windows, the performance of the GTSVM is compared to that of a conventional support vector machine (SVM), using repeated random sub-sampling method. The mean value of the classification rate/sensitivity is found to be 88%/86% for the GTSVM and 84%/83% for the SVM. The statistical evaluations show that the GTSVM significantly improves performance of the classification as compared to the SVM.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 42
Typ av publikation
tidskriftsartikel (28)
konferensbidrag (11)
doktorsavhandling (2)
rapport (1)
Typ av innehåll
refereegranskat (37)
övrigt vetenskapligt/konstnärligt (5)
Författare/redaktör
Loyd, Dan (10)
Wranne, Bengt (8)
Ask, Per, 1950- (7)
Lindén, Maria (6)
Janerot-Sjöberg, Bir ... (6)
visa fler...
Hult, Peter, 1964- (6)
Gharehbaghi, Arash (5)
Hult, Peter (5)
Jansson, Tomas (4)
Tibbling, Lita (3)
Borga, Magnus (2)
Ahlström, Christer (2)
Ahlström, Christer, ... (2)
Karlsson, Matts (2)
Wranne, Bengt, 1940- (2)
Pettersson, Nils-Eri ... (2)
Janerot-Sjöberg, Bir ... (2)
Ressner, Marcus, 196 ... (2)
Jurkonis, Rytis (2)
Kvikliene, Adriana (2)
Hoff, Lars (2)
Berglin, Lena (2)
Pettersson, N. E. (1)
Johansson, K. E. (1)
Chew, Michelle (1)
Wiklund, Urban (1)
Johansson, Anders (1)
Karlsson, M (1)
Lindecrantz, Kaj, Pr ... (1)
Andersson, R. (1)
Nylander, Eva (1)
Liljefeldt, Olle (1)
Laguna, Pablo, Profe ... (1)
Erlandsson, Björn-Er ... (1)
Sörnmo, Leif (1)
Hägglund, Sture (1)
Olsson, Jan (1)
Andersson, Gunnar (1)
Babic, Ankica, 1960- (1)
Öberg, Åke (1)
Brodin, Lars-Åke (1)
Babic, Ankica (1)
Sjöqvist, Bengt-Arne (1)
Åhlfeldt, Hans (1)
Ekstrand, Kristina (1)
Edwall, G (1)
Hök, B (1)
Skogh, Marcus (1)
Ekstrand, K. (1)
visa färre...
Lärosäte
Linköpings universitet (40)
Kungliga Tekniska Högskolan (7)
Mälardalens universitet (7)
Lunds universitet (3)
Språk
Engelska (38)
Svenska (4)
Forskningsämne (UKÄ/SCB)
Teknik (42)
Medicin och hälsovetenskap (8)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy