1.
  • Khodadad, Davood, 1985-, et al. (författare)
  • Optimized breath detection algorithm in electrical impedance tomography
  • 2018
  • Ingår i: Physiological Measurement. - : IOP Publishing. - 0967-3334 .- 1361-6579. ; 39:9
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: This paper defines a method for optimizing the breath delineation algorithms used in electrical impedance tomography (EIT). In lung EIT the identification of the breath phases is central for generating tidal impedance variation images, subsequent data analysis and clinical evaluation. The optimisation of these algorithms is particularly important in neonatal care since the existing breath detectors developed for adults may give insufficient reliability in neonates due to their very irregular breathing pattern.Approach: Our approach is generic in the sense that it relies on the definition of a gold standard and the associated definition of detector sensitivity and specificity, an optimisation criterion and a set of detector parameters to be investigated. The gold standard has been defined by 11 clinicians with previous experience with EIT and the performance of our approach is described and validated using a neonatal EIT dataset acquired within the EU-funded CRADL project.Main results: Three different algorithms are proposed that improve the breath detector performance by adding conditions on (1) maximum tidal breath rate obtained from zero-crossings of the EIT breathing signal, (2) minimum tidal impedance amplitude and (3) minimum tidal breath rate obtained from time-frequency analysis. As a baseline a zero-crossing algorithm has been used with some default parameters based on the Swisstom EIT device.Significance: Based on the gold standard, the most crucial parameters of the proposed algorithms are optimised by using a simple exhaustive search and a weighted metric defined in connection with the receiver operating characterics. This provides a practical way to achieve any desirable trade-off between the sensitivity and the specificity of the detectors.
  •  
2.
  • Grönlund, Christer, et al. (författare)
  • Imaging two-dimensional mechanical waves of skeletal muscle contraction
  • 2013
  • Ingår i: Ultrasound in Medicine and Biology. - : Elsevier BV. - 0301-5629 .- 1879-291X. ; 39:2, s. 360-369
  • Tidskriftsartikel (refereegranskat)abstract
    • Skeletal muscle contraction is related to rapid mechanical shortening and thickening. Recently, specialized ultrasound systems have been applied to demonstrate and quantify transient tissue velocities and one-dimensional (1-D) propagation of mechanical waves during muscle contraction. Such waves could potentially provide novel information on musculoskeletal characteristics, function and disorders. In this work, we demonstrate two-dimensional (2-D) mechanical wave imaging following the skeletal muscle contraction. B-mode image acquisition during multiple consecutive electrostimulations, speckle-tracking and a time-stamp sorting protocol were used to obtain 1.4 kHz frame rate 2-D tissue velocity imaging of the biceps brachii muscle contraction. The results present novel information on tissue velocity profiles and mechanical wave propagation. In particular, counter-propagating compressional and shear waves in the longitudinal direction were observed in the contracting tissue (speed 2.8-4.4 m/s) and a compressional wave in the transverse direction of the non-contracting muscle tissue (1.2-1.9 m/s). In conclusion, analysing transient 2-D tissue velocity allows simultaneous assessment of both active and passive muscle tissue properties. (E-mail: christer.gronlund@vll.se) (C) 2013 World Federation for Ultrasound in Medicine & Biology.
  •  
3.
  • Nilsson, Daniel, et al. (författare)
  • Patient-specific brain arteries molded as a flexible phantom model using 3D printed water-soluble resin
  • 2022
  • Ingår i: Scientific Reports. - : Nature Publishing Group. - 2045-2322. ; 12
  • Tidskriftsartikel (refereegranskat)abstract
    • Visualizing medical images from patients as physical 3D models (phantom models) have many roles in the medical field, from education to preclinical preparation and clinical research. However, current phantom models are generally generic, expensive, and time-consuming to fabricate. Thus, there is a need for a cost- and time-efficient pipeline from medical imaging to patient-specific phantom models. In this work, we present a method for creating complex 3D sacrificial molds using an off-the-shelf water-soluble resin and a low-cost desktop 3D printer. This enables us to recreate parts of the cerebral arterial tree as a full-scale phantom model (10×6×410×6×4 cm) in transparent silicone rubber (polydimethylsiloxane, PDMS) from computed tomography angiography images (CTA). We analyzed the model with magnetic resonance imaging (MRI) and compared it with the patient data. The results show good agreement and smooth surfaces for the arteries. We also evaluate our method by looking at its capability to reproduce 1 mm channels and sharp corners. We found that round shapes are well reproduced, whereas sharp features show some divergence. Our method can fabricate a patient-specific phantom model with less than 2 h of total labor time and at a low fabrication cost.
  •  
4.
  • Khodadad, Davood, 1985-, et al. (författare)
  • The Value of Phase Angle in Electrical Impedance Tomography Breath Detection
  • 2018
  • Ingår i: 2018 Progress in Electromagnetics Research Symposium (PIERS-Toyama). - : Electromagnetics Academy. - 9784885523168 - 9781538654552 ; , s. 1040-1043
  • Konferensbidrag (refereegranskat)abstract
    • The objective of this paper is to report our investigation demonstrating that the phase angle information of complex impedance could be a simple indicator of a breath cycle in chest Electrical Impedance Tomography (EIT). The study used clinical neonatal EIT data. The results show that measurement of the phase angle from complex EIT data can be used as a complementary information for improving the conventional breath detection algorithms.
  •  
5.
  • Grönlund, Christer, 1975-, et al. (författare)
  • Significant beat-to-beat variability of E/e’ irrespective of respiration
  • 2013
  • Ingår i: International cardiovascular forum. - : Barcaray Publishing. - 2409-3424 .- 2410-2636. ; 1:2, s. 88-89
  • Tidskriftsartikel (refereegranskat)abstract
    • The E/e’ ratio is commonly used in Doppler echocardiographic examinations to estimate the pulmonary capillary wedge pressure. The rationale of using this ratio is to combine left ventricular (LV) filling (E) and relaxation (e’) velocities to indirectly assess left atrial pressure. However, the accuracy of this index has recently been questioned, particularly in patients with controlled heart failure. Likewise, the potential beat-to-beat variability of such measurements remains undetermined. The cardiovascular system is subject to several oscillations with the potential of influencing LV function and its intra-cavitary pressures, hence measurements of its filling and relaxation velocities. The aim of this pilot study was to assess the beat-to-beat variability of the E/e’ ratio in one minute long examination in healthy subjects, and patients with various severity of amyloid heart disease. The results show that despite critical application of the standard echocardiographic recording recommendations, E/e’ beat-to-beat variability was 36 % (22 to 50%) in healthy subjects and 17 % (11-26%) in patients, and where the most severe amyloid heart disease had the least variability. Thus, clinical use of a single or few cardiac beats might not necessarily reflect an accurate ratio between the two velocities, and hence casts doubt over their diagnostic value.
  •  
6.
  • Virén, Tuomas, et al. (författare)
  • Comparison of ultrasound and optical coherence tomography techniques for evaluation of integrity of spontaneously repaired horse cartilage.
  • 2012
  • Ingår i: Journal of Medical Engineering & Technology. - : Informa Healthcare. - 0309-1902 .- 1464-522X. ; 36:3, s. 185-192
  • Tidskriftsartikel (refereegranskat)abstract
    • The aim of this study was to compare sensitivity of ultrasound and optical coherence tomography (OCT) techniques for the evaluation of the integrity of spontaneously repaired horse cartilage. Articular surfaces of horse intercarpal joints, featuring both intact tissue and spontaneously healed chondral or osteochondral defects, were imaged ex vivo with arthroscopic ultrasound and laboratory OCT devices. Quantitative ultrasound (integrated reflection coefficient (IRC), apparent integrated backscattering coefficient (AIB) and ultrasound roughness index (URI)) and optical parameters (optical reflection coefficient (ORC), optical roughness index (ORI) and optical backscattering (OBS)) were determined and compared with histological integrity and mechanical properties of the tissue. Spontaneously healed tissue could be quantitatively discerned from the intact tissue with ultrasound and OCT techniques. Furthermore, several significant correlations (p < 0.05) were detected between ultrasound and OCT parameters. Superior resolution of OCT provided a more accurate measurement of cartilage surface roughness, while the ultrasound backscattering from the inner structures of the cartilage matched better with the histological findings. Since the techniques were found to be complementary to each other, dual modality imaging techniques could provide a useful tool for the arthroscopic evaluation of the integrity of articular cartilage.
  •  
7.
  • Adjeiwaah, Mary, 1980- (författare)
  • Quality assurance for magnetic resonance imaging (MRI) in radiotherapy
  • 2017
  • Licentiatavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Magnetic resonance imaging (MRI) utilizes the magnetic properties of tissues to generate image-forming signals. MRI has exquisite soft-tissue contrast and since tumors are mainly soft-tissues, it offers improved delineation of the target volume and nearby organs at risk. The proposed Magnetic Resonance-only Radiotherapy (MR-only RT) work flow allows for the use of MRI as the sole imaging modality in the radiotherapy (RT) treatment planning of cancer. There are, however, issues with geometric distortions inherent with MR image acquisition processes. These distortions result from imperfections in the main magnetic field, nonlinear gradients, as well as field disturbances introduced by the imaged object. In this thesis, we quantified the effect of system related and patient-induced susceptibility geometric distortions on dose distributions for prostate as well as head and neck cancers. Methods to mitigate these distortions were also studied.In Study I, mean worst system related residual distortions of 3.19, 2.52 and 2.08 mm at bandwidths (BW) of 122, 244 and 488 Hz/pixel up to a radial distance of 25 cm from a 3T PET/MR scanner was measured with a large field of view (FoV) phantom. Subsequently, we estimated maximum shifts of 5.8, 2.9 and 1.5 mm due to patient-induced susceptibility distortions. VMAT-optimized treatment plans initially performed on distorted CT (dCT) images and recalculated on real CT datasets resulted in a dose difference of less than 0.5%. The magnetic susceptibility differences at tissue-metallic,-air and -bone interfaces result in local B0 magnetic field inhomogeneities. The distortion shifts caused by these field inhomogeneities can be reduced by shimming.  Study II aimed to investigate the use of shimming to improve the homogeneity of local  B0 magnetic field which will be beneficial for radiotherapy applications. A shimming simulation based on spherical harmonics modeling was developed. The spinal cord, an organ at risk is surrounded by bone and in close proximity to the lungs may have high susceptibility differences. In this region, mean pixel shifts caused by local B0 field inhomogeneities were reduced from 3.47±1.22 mm to 1.35±0.44 mm and 0.99±0.30 mm using first and second order shimming respectively. This was for a bandwidth of 122 Hz/pixel and an in-plane voxel size of 1×1 mm2.  Also examined in Study II as in Study I was the dosimetric effect of geometric distortions on 21 Head and Neck cancer treatment plans. The dose difference in D50 at the PTV between distorted CT and real CT plans was less than 1.0%.In conclusion, the effect of MR geometric distortions on dose plans was small. Generally, we found patient-induced susceptibility distortions were larger compared with residual system distortions at all delineated structures except the external contour. This information will be relevant when setting margins for treatment volumes and organs at risk.  The current practice of characterizing MR geometric distortions utilizing spatial accuracy phantoms alone may not be enough for an MR-only radiotherapy workflow. Therefore, measures to mitigate patient-induced susceptibility effects in clinical practice such as patient-specific correction algorithms are needed to complement existing distortion reduction methods such as high acquisition bandwidth and shimming.
  •  
8.
  • Ahlgren, Ulf, et al. (författare)
  • Imaging the pancreatic beta cell : chapter 13
  • 2011
  • Ingår i: Type 1 diabetes. - : InTech. - 9789533073620
  • Bokkapitel (refereegranskat)abstract
    • This book is a compilation of reviews about the pathogenesis of Type 1 Diabetes. T1D is a classic autoimmune disease. Genetic factors are clearly determinant but cannot explain the rapid, even overwhelming expanse of this disease. Understanding etiology and pathogenesis of this disease is essential. A number of experts in the field have covered a range of topics for consideration that are applicable to researcher and clinician alike. This book provides apt descriptions of cutting edge technologies and applications in the ever going search for treatments and cure for diabetes. Areas including T cell development, innate immune responses, imaging of pancreata, potential viral initiators, etc. are considered.
  •  
9.
  • Ali, Hazrat, et al. (författare)
  • A Deep Learning Pipeline for Identification of Motor Units in Musculoskeletal Ultrasound
  • 2020
  • Ingår i: IEEE Access. - : IEEE. - 2169-3536. ; 8, s. 170595-170608
  • Tidskriftsartikel (refereegranskat)abstract
    • Skeletal muscles are functionally regulated by populations of so-called motor units (MUs). An MU comprises a bundle of muscle fibers controlled by a neuron from the spinal cord. Current methods to diagnose neuromuscular diseases and monitor rehabilitation, and study sports sciences rely on recording and analyzing the bio-electric activity of the MUs. However, these methods provide information from a limited part of a muscle. Ultrasound imaging provides information from a large part of the muscle. It has recently been shown that ultrafast ultrasound imaging can be used to record and analyze the mechanical response of individual MUs using blind source separation. In this work, we present an alternative method - a deep learning pipeline - to identify active MUs in ultrasound image sequences, including segmentation of their territories and signal estimation of their mechanical responses (twitch train). We train and evaluate the model using simulated data mimicking the complex activation pattern of tens of activated MUs with overlapping territories and partially synchronized activation patterns. Using a slow fusion approach (based on 3D CNNs), we transform the spatiotemporal image sequence data to 2D representations and apply a deep neural network architecture for segmentation. Next, we employ a second deep neural network architecture for signal estimation. The results show that the proposed pipeline can effectively identify individual MUs, estimate their territories, and estimate their twitch train signal at low contraction forces. The framework can retain spatio-temporal consistencies and information of the mechanical response of MU activity even when the ultrasound image sequences are transformed into a 2D representation for compatibility with more traditional computer vision and image processing techniques. The proposed pipeline is potentially useful to identify simultaneously active MUs in whole muscles in ultrasound image sequences of voluntary skeletal muscle contractions at low force levels.
  •  
10.
  • Ali, Hazrat, et al. (författare)
  • Leveraging GANs for data scarcity of COVID-19 : Beyond the hype
  • 2023
  • Ingår i: 2023 IEEE/CVF Conference on Computer Vision and Pattern Recognition Workshops (CVPRW). - : IEEE Computer Society. - 9798350302493 ; , s. 659-667
  • Konferensbidrag (refereegranskat)abstract
    • Artificial Intelligence (AI)-based models can help in diagnosing COVID-19 from lung CT scans and X-ray images; however, these models require large amounts of data for training and validation. Many researchers studied Generative Adversarial Networks (GANs) for producing synthetic lung CT scans and X-Ray images to improve the performance of AI-based models. It is not well explored how good GAN-based methods performed to generate reliable synthetic data. This work analyzes 43 published studies that reported GANs for synthetic data generation. Many of these studies suffered data bias, lack of reproducibility, and lack of feedback from the radiologists or other domain experts. A common issue in these studies is the unavailability of the source code, hindering reproducibility. The included studies reported rescaling of the input images to train the existing GANs architecture without providing clinical insights on how the rescaling was motivated. Finally, even though GAN-based methods have the potential for data augmentation and improving the training of AI-based models, these methods fall short in terms of their use in clinical practice. This paper highlights research hotspots in countering the data scarcity problem, identifies various issues as well as potentials, and provides recommendations to guide future research. These recommendations might be useful to improve acceptability for the GAN-based approaches for data augmentation as GANs for data augmentation are increasingly becoming popular in the AI and medical imaging research community.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 117
Typ av publikation
tidskriftsartikel (69)
konferensbidrag (28)
annan publikation (9)
doktorsavhandling (7)
forskningsöversikt (2)
bokkapitel (1)
visa fler...
licentiatavhandling (1)
visa färre...
Typ av innehåll
refereegranskat (89)
övrigt vetenskapligt/konstnärligt (28)
Författare/redaktör
Yu, Jun, 1962- (25)
Grönlund, Christer (13)
Karlsson, Mikael (11)
Rohlén, Robin (11)
Nyholm, Tufve (10)
Larsson, Anne (8)
visa fler...
Garpebring, Anders (7)
Bayisa, Fekadu (7)
Häggström, Ida, 1982 ... (7)
Axelsson, Jan, 1966- (6)
Ali, Hazrat (6)
Wåhlin, Anders (6)
Sörensen, Jens (5)
Johansson, Lennart (5)
Johansson, Adam (5)
Trygg, Johan (4)
Eklund, Anders (4)
Axelsson, Jan (4)
Asklund, Thomas (4)
Brynolfsson, Patrik (4)
Khodadad, Davood, 19 ... (4)
Häggström, Ida (4)
Riklund, Katrine (3)
Dengel, Andreas (3)
Ahmed, Sheraz (3)
Stålberg, Erik (3)
Zarrinkoob, Laleh (3)
Malm, Jan (3)
Nordebo, Sven, 1963- (3)
Zhou, Zhiyong, 1989- (3)
Kuljus, Kristi (3)
Bolin, David (3)
Miedema, Martijn (3)
Yerworth, Rebecca (3)
Frerichs, Inez (3)
Farina, Dario (3)
Nyberg, Lars (2)
Söderström, Karin (2)
Wirestam, Ronnie (2)
Ahlgren, Ulf (2)
Olsson, Lars E (2)
Umander, Johannes (2)
Antfolk, Christian (2)
Blomqvist, Lennart (2)
Malm, Jan, Professor ... (2)
Sophocleous, Louiza (2)
Waldmann, Andreas D. (2)
Bayford, Richard (2)
Eklund, Anders, 1965 ... (2)
Gunnlaugsson, Adalst ... (2)
visa färre...
Lärosäte
Uppsala universitet (11)
Lunds universitet (7)
Göteborgs universitet (3)
Örebro universitet (3)
Chalmers tekniska högskola (3)
visa fler...
Kungliga Tekniska Högskolan (2)
Karolinska Institutet (2)
Sveriges Lantbruksuniversitet (2)
Luleå tekniska universitet (1)
Stockholms universitet (1)
Linnéuniversitetet (1)
visa färre...
Språk
Engelska (117)
Forskningsämne (UKÄ/SCB)
Teknik (117)
Medicin och hälsovetenskap (49)
Naturvetenskap (43)
Samhällsvetenskap (2)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy