SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "hsv:(TEKNIK OCH TEKNOLOGIER) hsv:(Medicinteknik) hsv:(Medicinsk laboratorie och mätteknik) ;hsvcat:3"

Sökning: hsv:(TEKNIK OCH TEKNOLOGIER) hsv:(Medicinteknik) hsv:(Medicinsk laboratorie och mätteknik) > Medicin och hälsovetenskap

  • Resultat 1-10 av 313
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Hafid, Abdelakram, et al. (författare)
  • Full Impedance Cardiography Measurement Device Using Raspberry PI3 and System-on-Chip Biomedical Instrumentation Solutions
  • 2018
  • Ingår i: IEEE journal of biomedical and health informatics. - : IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. - 2168-2194 .- 2168-2208. ; 22:6, s. 1883-1894
  • Tidskriftsartikel (refereegranskat)abstract
    • Impedance cardiography (ICG) is a noninvasive method for monitoring cardiac dynamics using electrical bioimpedance (EBI) measurements. Since its appearance more than 40 years ago, ICG has been used for assessing hemodynamic parameters. This paper presents a measurement system based on two System on Chip (SoC) solutions and Raspberry PI, implementing both a full three-lead ECG recorder and an impedance cardiographer, for educational and research development purposes. Raspberry PI is a platform supporting Do-I t-Yourself project and education applications across the world. The development is part of Biosignal PI, an open hardware platform focusing in quick prototyping of physiological measurement instrumentation. The SoC used for sensing cardiac biopotential is the ADAS1000, and for the EBI measurement is the AD5933. The recordings were wirelessly transmitted through Bluetooth to a PC, where the waveforms were displayed, and hemodynamic parameters such as heart rate, stroke volume, ejection time and cardiac output were extracted from the ICG and ECG recordings. These results show how Raspberry PI can be used for quick prototyping using relatively widely available and affordable components, for supporting developers in research and engineering education. The design and development documents will be available on www.BiosignalPl.com, for open access under a Non Commercial-Share A like 4.0 International License.
  •  
2.
  • Munthe, Christian, 1962 (författare)
  • Etiska aspekter på regenerativ medicin : Ethical aspects on regenerative medicine
  • 2003
  • Ingår i: SNIB-konferensen 2003, Chalmers tekniska högskola, Göteborg, 16-18 maj 2003.
  • Konferensbidrag (övrigt vetenskapligt/konstnärligt)abstract
    • Inom den regenerativa medicinen strävar man efter att ersätta skadat eller sjukligt biologiskt mänskligt material (celler, organ, kroppsdelar) med nya biologiska komponenter. Området aktualiserar en rad etiska frågeställningar vad gäller (1) produktionen av ersättningsmaterialet (t.ex. embryonala stamceller eller införskaffande av transplantationsvävnad från donatorer), (2) risker i samband med försök på människa (genmodifierat material, material från djur), samt (3) gränserna för hur långt man bör gå i denna slags försök att förlänga människans livsspann. Föredraget ger en kort översikt över dessa frågeställningar, ståndpunkter och argument i debatten kring dem.
  •  
3.
  • Iredahl, Fredrik, 1988- (författare)
  • Assessment of microvascular and metabolic responses in the skin
  • 2016
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • The general aim of this project was to develop experimental in vivo models that allow for minimally invasive investigations of responses in the skin to microvascular and metabolic provocations. The cutaneous microvasculature has emerged as a valuable model and been proposed to mirror the microcirculation in other organs. Dysfunction in the cutaneous microcirculation has thus been linked to systemic diseases such as hypertension and diabetes mellitus. Models for investigating skin responses could facilitate the understanding of pathophysiological mechanisms as well as effects of drugs.In the first study, three optical measurement techniques (laser Doppler flowmetry (LDF), laser speckle contrast imaging (LSCI) and tissue viability imaging (TiVi)) were compared against each other and showed differences in their ability to detect microvascular responses to provocations in the skin. TiVi was found more sensitive for measurement of noradrenaline-induced vasoconstriction, while LSCI was more sensitive for measurement of vascular occlusion. In the second study, microvascular responses in the skin to iontophoresis of vasoactive drugs were found to depend on the drug delivery protocol. Perfusion half-life was defined and used to describe the decay in the microvascular response to a drug after iontophoresis. In the third study, the role of nitric oxide (NO) was assessed during iontophoresis of insulin. The results showed a NO-dependent vasodilation in the skin by insulin. In the fourth study the vasoactive and metabolic effects of insulin were studied after both local and endogenous administration. Local delivery of insulin increased skin blood flow, paralleled by increased skin concentrations of interstitial pyruvate and lactate, although no change in glucose concentration was observed. An oral glucose load resulted in an increased insulin concentration in the skin paralleled by an increase in blood flow, as measured using the microdialysis urea clearance technique, although no changes in perfusion was measured by LSCI.The thesis concludes that when studying skin microvascular responses, the choice of measurement technique and the drug delivery protocol has an impact on the measurement results, and should therefore be carefully considered. The thesis also concludes that insulin has metabolic and vasodilatory effects in the skin both when administered locally and as an endogenous response to an oral glucose load. The vasodilatory effect of insulin in the skin is mediated by nitric oxide.
  •  
4.
  • Arvidsson, Daniel, 1974, et al. (författare)
  • Re-examination of accelerometer data processing and calibration for the assessment of physical activity intensity.
  • 2019
  • Ingår i: Scandinavian Journal of Medicine and Science in Sports. - : John Wiley & Sons. - 0905-7188 .- 1600-0838. ; 29:10, s. 1442-1452
  • Tidskriftsartikel (refereegranskat)abstract
    • This review reexamines use of accelerometer and oxygen uptake data for assessment of activity intensity. Accelerometers capture mechanical work, while oxygen uptake captures the energy cost of this work. Frequency filtering needs to be considered when processing acceleration data. A too restrictive filter attenuates the acceleration signal for walking and, to a higher degree, for running. This measurement error affects shorter (children) more than taller (adults) individuals due to their higher movement frequency. Less restrictive filtering includes more movement related signals and provide measures that better capture mechanical work, but may include more noise. An optimal filter cut-point is determined where most relevant acceleration signals are included. Further, accelerometer placement affects what part of mechanical work being captured. While the waist placement captures total mechanical work and therefore contributes to measures of activity intensity equivalent by age and stature, the thigh and wrist placements capture more internal work and do not provide equivalent measures. Value calibration of accelerometer measures is usually performed using measured oxygen uptake with the metabolic equivalent of task (MET) as reference measure of activity intensity. However, the use of MET is not stringent and is not a measure of activity intensity equivalent by age and stature. A candidate measure is the mass-specific net oxygen uptake, VO2 net (VO2 tot - VO2 stand). To improve measurement of physical activity intensity using accelerometers, research developments are suggested concerning processing of accelerometer data, use of energy expenditure as reference for activity intensity, and calibration procedure with absolute versus relative intensity. This article is protected by copyright. All rights reserved.
  •  
5.
  •  
6.
  • Ahlander, Britt-Marie, 1954-, et al. (författare)
  • An echo-planar imaging sequence is superior to a steady-state free precession sequence for visual as well as quantitative assessment of cardiac magnetic resonance stress perfusion
  • 2017
  • Ingår i: Clinical Physiology and Functional Imaging. - : Blackwell Publishing. - 1475-0961 .- 1475-097X. ; 37:1, s. 52-61
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: To assess myocardial perfusion, steady-state free precession cardiac magnetic resonance (SSFP, CMR) was compared with gradient-echo-echo-planar imaging (GRE-EPI) using myocardial perfusion scintigraphy (MPS) as reference.METHODS: Cardiac magnetic resonance perfusion was recorded in 30 patients with SSFP and in another 30 patients with GRE-EPI. Timing and extent of inflow delay to the myocardium was visually assessed. Signal-to-noise (SNR) and contrast-to-noise (CNR) ratios were calculated. Myocardial scar was visualized with a phase-sensitive inversion recovery sequence (PSIR). All scar positive segments were considered pathologic. In MPS, stress and rest images were used as in clinical reporting. The CMR contrast wash-in slope was calculated and compared with the stress score from the MPS examination. CMR scar, CMR perfusion and MPS were assessed separately by one expert for each method who was blinded to other aspects of the study.RESULTS: Visual assessment of CMR had a sensitivity for the detection of an abnormal MPS at 78% (SSFP) versus 91% (GRE-EPI) and a specificity of 58% (SSFP) versus 84% (GRE-EPI). Kappa statistics for SSFP and MPS was 0·29, for GRE-EPI and MPS 0·72. The ANOVA of CMR perfusion slopes for all segments versus MPS score (four levels based on MPS) had correlation r = 0·64 (SSFP) and r = 0·96 (GRE-EPI). SNR was for normal segments 35·63 ± 11·80 (SSFP) and 17·98 ± 8·31 (GRE-EPI), while CNR was 28·79 ± 10·43 (SSFP) and 13·06 ± 7·61 (GRE-EPI).CONCLUSION: GRE-EPI displayed higher agreement with the MPS results than SSFP despite significantly lower signal intensity, SNR and CNR.
  •  
7.
  • Fhager, Andreas, 1976, et al. (författare)
  • 3D Simulations of Intracerebral Hemorrhage Detection Using Broadband Microwave Technology
  • 2019
  • Ingår i: Sensors. - : MDPI AG. - 1424-8220. ; 19:16
  • Tidskriftsartikel (refereegranskat)abstract
    • Early, preferably prehospital, detection of intracranial bleeding after trauma or stroke would dramatically improve the acute care of these large patient groups. In this paper, we use simulated microwave transmission data to investigate the performance of a machine learning classification algorithm based on subspace distances for the detection of intracranial bleeding. A computational model, consisting of realistic human head models of patients with bleeding, as well as healthy subjects, was inserted in an antenna array model. The Finite-Difference Time-Domain (FDTD) method was then used to generate simulated transmission coefficients between all possible combinations of antenna pairs. These transmission data were used both to train and evaluate the performance of the classification algorithm and to investigate its ability to distinguish patients with versus without intracranial bleeding. We studied how classification results were affected by the number of healthy subjects and patients used to train the algorithm, and in particular, we were interested in investigating how many samples were needed in the training dataset to obtain classification results better than chance. Our results indicated that at least 200 subjects, i.e., 100 each of the healthy subjects and bleeding patients, were needed to obtain classification results consistently better than chance (p < 0.05 using Student's t-test). The results also showed that classification results improved with the number of subjects in the training data. With a sample size that approached 1000 subjects, classifications results characterized as area under the receiver operating curve (AUC) approached 1.0, indicating very high sensitivity and specificity.
  •  
8.
  • Jing, Yujia, 1985 (författare)
  • Hyperthermia-responsive liposomal systems
  • 2015
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Abstract Sophisticated liposomal systems are emerging at an increasing rate to meet the demands for multifunctional drug carriers in chemotherapies in combined with hyperthermia. For example, liposomal drug carriers for temperature-controlled drug release under hyperthermic conditions have recently been tested in clinical trials. More advanced designs of liposomes are expected to release encapsulated contents and activate hidden surface-functions in response to heat stimulus. Towards this aim, the present thesis is focused on formulating asymmetric lipid systems that can preserve functional moieties, and reactivate the targeted function as well as release the encapsulated compounds upon local heating. The design of the asymmetric liposomal systems utilizes the heat-activated transmembrane lipid diffusion during gel to liquid-crystalline phase transitions of the lipid membranes.Rational design of advanced liposomal drug-delivery systems will require understanding of the physicochemical properties of lipid membranes under, e.g., hyperthermic conditions. Here, supported lipid membranes on planar solid surfaces were used for model studies of lipid composition yielding a gel to liquid crystalline phase-transition temperature in the range 40 – 45 °C. It was found that the liposome-to-membrane formation process is not only size-dependent but also governed by temperature. Two methods of preparing supported asymmetric lipid membranes were investigated. As a proof-of-concept, the upper leaflets were either replaced or chemically transformed by enzymatic hydrolysis. The processes were monitored using surface sensitive techniques such as quartz crystal microbalance with dissipation (QCM-D) and dual polarization interferometry (DPI). The asymmetric structures were stable at a room temperature, while lipid flip-flop was induced upon increasing of the temperature. Transmembrane lipid exchange in the asymmetric structure under hyperthermic conditions was demonstrated by detecting, through streptavidin binding, biotinylated lipids appearing at the top leaflet which were first located in the lower leaflet. The protocols developed for the supported lipid systems were adapted for the preparation of asymmetric liposomes. Biotinylated asymmetric liposomes were used as a model system to demonstrate the principle of heat-activated targeting of asymmetric liposomes to streptavidin-coated surfaces. More biologically relevant interaction was utilized to replace the biotin-streptavidin function, where asymmetric cationic liposomes were binding to anionic supported membrane immobilized surfaces upon heating. The described strategies for assembly of asymmetric supported membranes provide a guide to the development of multifunctional drug carriers. The protocols used in experiments with supported membranes were readily adapted to the preparation of asymmetric liposomes. The ongoing study tests the asymmetric liposomes in vitro, which is designed to demonstrate hyperthermia treatment can enhance accumulation of liposomes in FaDu cells, and at the same time activate release of the encapsulated components. The results of in vitro tests can be used to analyze the feasibility of utilizing the asymmetric liposomes as a platform in vivo to explore further improvement in their functions upon microwave hyperthermia.
  •  
9.
  • Buendia, Ruben, 1982, et al. (författare)
  • Estimation of body fluids with bioimpedance spectroscopy: state of the art methods and proposal of novel methods
  • 2015
  • Ingår i: Physiological Measurement. - : IOP Publishing. - 0967-3334 .- 1361-6579. ; 36:10
  • Tidskriftsartikel (refereegranskat)abstract
    • Determination of body fluids is a useful common practice in determination of disease mechanisms and treatments. Bioimpedance spectroscopy (BIS) methods are non-invasive, inexpensive and rapid alternatives to reference methods such as tracer dilution. However, they are indirect and their robustness and validity are unclear. In this article, state of the art methods are reviewed, their drawbacks identified and new methods are proposed. All methods were tested on a clinical database of patients receiving growth hormone replacement therapy. Results indicated that most BIS methods are similarly accurate (e.g. < 0.5 +/- 3.0% mean percentage difference for total body water) for estimation of body fluids. A new model for calculation is proposed that performs equally well for all fluid compartments (total body water, extra-and intracellular water). It is suggested that the main source of error in extracellular water estimation is due to anisotropy, in total body water estimation to the uncertainty associated with intracellular resistivity and in determination of intracellular water a combination of both.
  •  
10.
  • Ahlander, Britt-Marie, 1954- (författare)
  • Magnetic Resonance Imaging of the Heart : Image quality, measurement accuracy and patient experience
  • 2016
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Background: Non-invasive diagnostic imaging of atherosclerotic coronary artery disease (CAD) is frequently carried out with cardiovascular magnetic resonance imaging (CMR) or myocardial perfusion single photon emission computed tomography (MPS). CMR is the gold standard for the evaluation of scar after myocardial infarction and MPS the clinical gold standard for ischemia. Magnetic Resonance Imaging (MRI) is at times difficult for patients and may induce anxiety while patient experience of MPS is largely unknown.Aims: To evaluate image quality in CMR with respect to the sequences employed, the influence of atrial fibrillation, myocardial perfusion and the impact of patient information. Further, to study patient experience in relation to MRI with the goal of improving the care of these patients.Method: Four study designs have been used. In paper I, experimental cross-over, paper (II) experimental controlled clinical trial, paper (III) psychometric crosssectional study and paper (IV) prospective intervention study. A total of 475 patients ≥ 18 years with primarily cardiac problems (I-IV) except for those referred for MRI of the spine (III) were included in the four studies.Result: In patients (n=20) with atrial fibrillation, a single shot steady state free precession (SS-SSFP) sequence showed significantly better image quality than the standard segmented inversion recovery fast gradient echo (IR-FGRE) sequence (I). In first-pass perfusion imaging the gradient echo-echo planar imaging sequence (GREEPI) (n=30) had lower signal-to-noise and contrast–to-noise ratios than the steady state free precession sequence (SSFP) (n=30) but displayed a higher correlation with the MPS results, evaluated both qualitatively and quantitatively (II). The MRIAnxiety Questionnaire (MRI-AQ) was validated on patients, referred for MRI of either the spine (n=193) or the heart (n=54). The final instrument had 15 items divided in two factors regarding Anxiety and Relaxation. The instrument was found to have satisfactory psychometric properties (III). Patients who prior CMR viewed an information video scored significantly (lower) better in the factor Relaxation, than those who received standard information. Patients who underwent MPS scored lower on both factors, Anxiety and Relaxation. The extra video information had no effect on CMR image quality (IV).Conclusion: Single shot imaging in atrial fibrillation produced images with less artefact than a segmented sequence. In first-pass perfusion imaging, the sequence GRE-EPI was superior to SSFP. A questionnaire depicting anxiety during MRI showed that video information prior to imaging helped patients relax but did not result in an improvement in image quality.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 313
Typ av publikation
tidskriftsartikel (196)
konferensbidrag (62)
doktorsavhandling (30)
forskningsöversikt (12)
bokkapitel (7)
licentiatavhandling (3)
visa fler...
annan publikation (2)
konstnärligt arbete (1)
rapport (1)
visa färre...
Typ av innehåll
refereegranskat (254)
övrigt vetenskapligt/konstnärligt (58)
populärvet., debatt m.m. (1)
Författare/redaktör
Lindecrantz, Kaj, 19 ... (21)
Seoane, Fernando, 19 ... (15)
Thordstein, Magnus (11)
Kjellmer, Ingemar, 1 ... (9)
Persson, Mikael, 195 ... (9)
Olsson, Torsten, 193 ... (8)
visa fler...
Löfgren, Nils, 1969 (8)
Cederström, Björn (7)
Seoane, Fernando (6)
Danielsson, Mats (6)
Candefjord, Stefan, ... (6)
Lindecrantz, Kaj (5)
Enqvist, Olof, 1981 (5)
Brodin, Lars-Åke (5)
Hammarsten, Ola (4)
Larsson, Anders (4)
Schmidt, Florian M. (4)
Edenbrandt, Lars, 19 ... (4)
Malmberg, Per, 1974 (4)
Schneiderman, Justin ... (4)
Pfeiffer, Christoph, ... (4)
Ruffieux, Silvia, 19 ... (4)
Dobsicek Trefna, Han ... (4)
Ternström, Sten, 195 ... (4)
Ebbers, Tino, 1972- (4)
Börjesson, Mats, 196 ... (3)
Ortiz Catalan, Max J ... (3)
Sandberg, Frida (3)
Munthe, Christian, 1 ... (3)
Romu, Thobias (3)
Janerot-Sjöberg, Bir ... (3)
Laurell, Thomas (3)
Dahlqvist Leinhard, ... (3)
Osvalder, Anna-Lisa, ... (3)
Lundqvist, D (3)
Winkler, Dag, 1957 (3)
Danielsson, Mats, Pr ... (3)
Kero, Timo, 1973 (3)
Andersen, L. M. (3)
Grip, Helena (3)
Forsgren, Mikael (3)
Hedström, Erik (3)
Arvidsson, Daniel, 1 ... (3)
Fridolfsson, Jonatan ... (3)
Reinfeldt, Sabine, 1 ... (3)
Aletras, Anthony H (3)
Dyverfeldt, Petter, ... (3)
Borg, Christel (3)
Håkansson, Bo, 1953 (3)
Broberg, Marita, 197 ... (3)
visa färre...
Lärosäte
Chalmers tekniska högskola (116)
Göteborgs universitet (76)
Kungliga Tekniska Högskolan (70)
Lunds universitet (55)
Linköpings universitet (36)
Högskolan i Borås (31)
visa fler...
Karolinska Institutet (30)
Umeå universitet (25)
Uppsala universitet (23)
Örebro universitet (8)
Malmö universitet (7)
Gymnastik- och idrottshögskolan (6)
Linnéuniversitetet (5)
Stockholms universitet (4)
RISE (4)
Blekinge Tekniska Högskola (4)
Luleå tekniska universitet (3)
Sveriges Lantbruksuniversitet (3)
Högskolan i Halmstad (2)
Jönköping University (2)
Mälardalens universitet (1)
Mittuniversitetet (1)
Högskolan i Skövde (1)
Högskolan Dalarna (1)
VTI - Statens väg- och transportforskningsinstitut (1)
visa färre...
Språk
Engelska (304)
Svenska (7)
Tyska (1)
Rumänska (1)
Forskningsämne (UKÄ/SCB)
Teknik (313)
Naturvetenskap (68)
Samhällsvetenskap (9)
Lantbruksvetenskap (2)
Humaniora (2)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy