SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "hsv:(TEKNIK OCH TEKNOLOGIER) hsv:(Medicinteknik) hsv:(Medicinsk laboratorie och mätteknik) ;lar1:(hkr)"

Sökning: hsv:(TEKNIK OCH TEKNOLOGIER) hsv:(Medicinteknik) hsv:(Medicinsk laboratorie och mätteknik) > Högskolan Kristianstad

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Anderson, Rachele, et al. (författare)
  • Effects of Age, BMI, anxiety and stress on the parameters of a stochastic model for heart rate variability including respiratory information
  • 2018
  • Ingår i: BIOSIGNALS 2018 - 11th International Conference on Bio-Inspired Systems and Signal Processing, Proceedings; Part of 11th International Joint Conference on Biomedical Engineering Systems and Technologies, BIOSTEC 2018. - : SCITEPRESS - Science and Technology Publications. - 9789897582790 ; 4, s. 17-25
  • Konferensbidrag (refereegranskat)abstract
    • Recent studies have focused on investigating different factors that may affect heart rate variability (HRV), pointing especially to the effects of age, gender and stress level. Other findings raise the importance of considering the respiratory frequency in the analysis of HRV signals. In this study, we evaluate the effect of several covariates on the parameters of a stochastic model for HRV. The data was recorded from 47 test participants, whose breathing was controlled by following a metronome with increasing frequency. This setup allows for a controlled acquisition of respiratory related HRV data covering the frequency range in which adults breathe in different everyday situations. A stochastic model, known as Locally Stationary Chirp Process, accounts for the respiratory signal information and models the HRV data. The model parameters are estimated with a novel inference method based on the separability features possessed by the process covariance function. Least square regression analysis using several available covariates is used to investigate the correlation with the stochastic model parameters. The results show statistically significant correlation of the model parameters with age, BMI, State and Trait Anxiety as well as stress level.
  •  
2.
  • Huang, Xin, et al. (författare)
  • Human interactive secure key and ID exchange protocols in body sensor networks
  • 2013
  • Ingår i: IET Information Security. - : Institution of Engineering and Technology. - 1751-8709 .- 1751-8717. ; 7:1, s. 30-38
  • Tidskriftsartikel (refereegranskat)abstract
    • A body sensor network (BSN) is typically a wearable wireless sensor network. Security protection is critical to BSNs, since they collect sensitive personal information. Generally speaking, security protection of BSN relies on identity (ID) and key distribution protocols. Most existing protocols are designed to run in general wireless sensor networks, and are not suitable for BSNs. After carefully examining the characteristics of BSNs, the authors propose human interactive empirical channel-based security protocols, which include an elliptic curve Diffie–Hellman version of symmetric hash commitment before knowledge protocol and an elliptic curve Diffie–Hellman version of hash commitment before knowledge protocol. Using these protocols, dynamically distributing keys and IDs become possible. As opposite to present solutions, these protocols do not need any pre-deployment of keys or secrets. Therefore compromised and expired keys or IDs can be easily changed. These protocols exploit human users as temporary trusted third parties. The authors, thus, show that the human interactive channels can help them to design secure BSNs.
  •  
3.
  • Khan, Nabeel Ali, et al. (författare)
  • Performance comparison of time-frequency distributions for estimation of instantaneous frequency of heart rate variability signals
  • 2017
  • Ingår i: Applied Sciences (Switzerland). - : MDPI AG. - 2076-3417 .- 1454-5101. ; 7:3
  • Tidskriftsartikel (refereegranskat)abstract
    • The instantaneous frequency (IF) of a non-stationary signal is usually estimated from a time-frequency distribution (TFD). The IF of heart rate variability (HRV) is an important parameter because the power in a frequency band around the IF can be used for the interpretation and analysis of the respiratory rate but also for a more accurate analysis of heart rate (HR) signals. In this study, we compare the performance of five states of the art kernel-based time-frequency distributions (TFDs) in terms of their ability to accurately estimate the IF of HR signals. The selected TFDs include three widely used fixed kernel methods: the modified B distribution, the S-method and the spectrogram; and two adaptive kernel methods: the adaptive optimal kernel TFD and the recently developed adaptive directional TFD. The IF of the respiratory signal, which is usually easier to estimate as the respiratory signal is a mono-component with small amplitude variations with time, is used as a reference to examine the accuracy of the HRV IF estimates. Experimental results indicate that the most reliable estimates are obtained using the adaptive directional TFD in comparison to other commonly used methods such as the adaptive optimal kernel TFD and the modified B distribution.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3
Typ av publikation
tidskriftsartikel (2)
konferensbidrag (1)
Typ av innehåll
refereegranskat (3)
Författare/redaktör
Sandsten, Maria (2)
Jönsson, Peter (2)
Wang, Qinghua (1)
Anderson, Rachele (1)
Huang, Xin (1)
Zheng, Yan (1)
visa fler...
Chen, Bangdao (1)
Markham, Andrew (1)
Roscoe, Andrew Willi ... (1)
Khan, Nabeel Ali (1)
visa färre...
Lärosäte
Lunds universitet (2)
Språk
Engelska (3)
Forskningsämne (UKÄ/SCB)
Teknik (3)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy