1.
  • Abayazid, Fady, et al. (författare)
  • A New Assessment of Bicycle Helmets: The Brain Injury Mitigation Effects of New Technologies in Oblique Impacts
  • 2021
  • Ingår i: Annals of Biomedical Engineering. - : Springer Science and Business Media LLC. - 1573-9686 .- 0090-6964. ; 49:10, s. 2716-2733
  • Tidskriftsartikel (refereegranskat)abstract
    • New helmet technologies have been developed to improve the mitigation of traumatic brain injury (TBI) in bicycle accidents. However, their effectiveness under oblique impacts, which produce more strains in the brain in comparison with vertical impacts adopted by helmet standards, is still unclear. Here we used a new method to assess the brain injury prevention effects of 27 bicycle helmets in oblique impacts, including helmets fitted with a friction-reducing layer (MIPS), a shearing pad (SPIN), a wavy cellular liner (WaveCel), an airbag helmet (Hövding) and a number of conventional helmets. We tested whether helmets fitted with the new technologies can provide better brain protection than conventional helmets. Each helmeted headform was dropped onto a 45° inclined anvil at 6.3 m/s at three locations, with each impact location producing a dominant head rotation about one anatomical axes of the head. A detailed computational model of TBI was used to determine strain distribution across the brain and in key anatomical regions, the corpus callosum and sulci. Our results show that, in comparison with conventional helmets, the majority of helmets incorporating new technologies significantly reduced peak rotational acceleration and velocity and maximal strain in corpus callosum and sulci. Only one helmet with MIPS significantly increased strain in the corpus collosum. The helmets fitted with MIPS and WaveCel were more effective in reducing strain in impacts producing sagittal rotations and a helmet fitted with SPIN in coronal rotations. The airbag helmet was effective in reducing brain strain in all impacts, however, peak rotational velocity and brain strain heavily depended on the analysis time. These results suggest that incorporating different impact locations in future oblique impact test methods and designing helmet technologies for the mitigation of head rotation in different planes are key to reducing brain injuries in bicycle accidents.
  •  
2.
  • Fröberg, Asa, et al. (författare)
  • High variability in strain estimation errors when using a commercial ultrasound speckle tracking algorithm on tendon tissue
  • 2016
  • Ingår i: Acta Radiologica. - : Sage Publications. - 0284-1851 .- 1600-0455. ; 57:10, s. 1223-1229
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Ultrasound speckle tracking offers a non-invasive way of studying strain in the free Achilles tendon where no anatomical landmarks are available for tracking. This provides new possibilities for studying injury mechanisms during sport activity and the effects of shoes, orthotic devices, and rehabilitation protocols on tendon biomechanics. Purpose: To investigate the feasibility of using a commercial ultrasound speckle tracking algorithm for assessing strain in tendon tissue. Material and Methods: A polyvinyl alcohol (PVA) phantom, three porcine tendons, and a human Achilles tendon were mounted in a materials testing machine and loaded to 4% peak strain. Ultrasound long-axis cine-loops of the samples were recorded. Speckle tracking analysis of axial strain was performed using a commercial speckle tracking software. Estimated strain was then compared to reference strain known from the materials testing machine. Two frame rates and two region of interest (ROI) sizes were evaluated. Results: Best agreement between estimated strain and reference strain was found in the PVA phantom (absolute error in peak strain: 0.21 +/- 0.08%). The absolute error in peak strain varied between 0.72 +/- 0.65% and 10.64 +/- 3.40% in the different tendon samples. Strain determined with a frame rate of 39.4Hz had lower errors than 78.6Hz as was the case with a 22mm compared to an 11mm ROI. Conclusion: Errors in peak strain estimation showed high variability between tendon samples and were large in relation to strain levels previously described in the Achilles tendon.
  •  
3.
  • Morin, Maxim, et al. (författare)
  • Skin hydration dynamics investigated by electrical impedance techniques in vivo and in vitro
  • 2020
  • Ingår i: Scientific reports. - : Springer Science and Business Media LLC. - 2045-2322. ; 10:1, s. 17218-
  • Tidskriftsartikel (refereegranskat)abstract
    • Skin is easily accessible for transdermal drug delivery and also attractive for biomarker sampling. These applications are strongly influenced by hydration where elevated hydration generally leads to increased skin permeability. Thus, favorable transdermal delivery and extraction conditions can be easily obtained by exploiting elevated skin hydration. Here, we provide a detailed in vivo and in vitro investigation of the skin hydration dynamics using three techniques based on electrical impedance spectroscopy. Good correlation between in vivo and in vitro results is demonstrated, which implies that simple but realistic in vitro models can be used for further studies related to skin hydration (e.g., cosmetic testing). Importantly, the results show that hydration proceeds in two stages. Firstly, hydration between 5 and 10 min results in a drastic skin impedance change, which is interpreted as filling of superficial voids in skin with conducting electrolyte solution. Secondly, a subtle impedance change is observed over time, which is interpreted as leveling of the water gradient across skin leading to structural relaxation/changes of the macromolecular skin barrier components. With respect to transdermal drug delivery and extraction of biomarkers; 1 h of hydration is suggested to result in beneficial and stable conditions in terms of high skin permeability and extraction efficiency.
  •  
4.
  • Mårtensson, Mattias, et al. (författare)
  • Assessment of left ventricular volumes using simplified 3-D echocardiography and computed tomography - a phantom and clinical study
  • 2008
  • Ingår i: Cardiovascular Ultrasound. - : Springer Science and Business Media LLC. - 1476-7120. ; 6
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives: To compare the accuracy of simplified 3-dimensional (3-D) echocardiography vs. multi-slice computed tomography (MSCT) software for the quantification of left ventricular (LV) volumes. Design: Three-D echocardiography (3-planes approach) and MSCT-CardIQ software were calibrated by measuring known volumes of 10 phantoms designed to closely mimic blood-endocardium interface. Subsequently, LV volumes were measured with both the methods in 9 patients referred routinely for coronary angiography and the agreement between the measurements was evaluated. Results: Simplified 3D-echocardiography provided higher degree of agreement between the measured and true phantom volumes (mean difference 0 +/- 1 ml, variation range + 4 to -4 ml) than MSCT software (mean difference 6 +/- 5 ml; variation range + 22 to -10 ml). The agreement between LV measurements in the patients was considerably poorer, with significantly larger volumes produced by MSCT (mean difference - 23 +/- 40 ml, variation between + 93 and -138 ml). Conclusion: Simplified 3-D echocardiography provides more accurate assessment of phantom volumes than MSCT-CardIQ software. The discrepancy between the results of LV measurements with the two methods is even greater and does not warrant their interchangeable diagnostic use.
  •  
5.
  • Abrahamsson, S., et al. (författare)
  • Multifocus structured illumination microscopy for fast volumetric super-resolution imaging
  • 2017
  • Ingår i: Biomedical Optics Express. - : OSA - The Optical Society. - 2156-7085. ; 8:9, s. 4135-4140
  • Tidskriftsartikel (refereegranskat)abstract
    • We here report for the first time the synergistic implementation of structured illumination microscopy (SIM) and multifocus microscopy (MFM). This imaging modality is designed to alleviate the problem of insufficient volumetric acquisition speed in superresolution biological imaging. SIM is a wide-field super-resolution technique that allows imaging with visible light beyond the classical diffraction limit. Employing multifocus diffractive optics we obtain simultaneous wide-field 3D imaging capability in the SIM acquisition sequence, improving volumetric acquisition speed by an order of magnitude. Imaging performance is demonstrated on biological specimens.
  •  
6.
  •  
7.
  • Biasetti, Jacopo, et al. (författare)
  • Hemodynamics of the Normal Aorta Compared to Fusiform and Saccular Abdominal Aortic Aneurysms with Emphasis on a Potential Thrombus Formation Mechanism
  • 2010
  • Ingår i: Annals of Biomedical Engineering. - : Springer Science and Business Media LLC. - 0090-6964 .- 1573-9686. ; 38:2, s. 380-390
  • Tidskriftsartikel (refereegranskat)abstract
    • Abdominal Aortic Aneurysms (AAAs), i.e., focal enlargements of the aorta in the abdomen are frequently observed in the elderly population and their rupture is highly mortal. An intra-luminal thrombus is found in nearly all aneurysms of clinically relevant size and multiply affects the underlying wall. However, from a biomechanical perspective thrombus development and its relation to aneurysm rupture is still not clearly understood. In order to explore the impact of blood flow on thrombus development, normal aortas (n = 4), fusiform AAAs (n = 3), and saccular AAAs (n = 2) were compared on the basis of unsteady Computational Fluid Dynamics simulations. To this end patient-specific luminal geometries were segmented from Computerized Tomography Angiography data and five full heart cycles using physiologically realistic boundary conditions were analyzed. Simulations were carried out with computational grids of about half a million finite volume elements and the Carreau-Yasuda model captured the non-Newtonian behavior of blood. In contrast to the normal aorta the flow in aneurysm was highly disturbed and, particularly right after the neck, flow separation involving regions of high streaming velocities and high shear stresses were observed. Naturally, at the expanded sites of the aneurysm average flow velocity and wall shear stress were much lower compared to normal aortas. These findings suggest platelets activation right after the neck, i.e., within zones of pronounced recirculation, and platelet adhesion, i.e., thrombus formation, downstream. This mechanism is supported by recirculation zones promoting the advection of activated platelets to the wall.
  •  
8.
  • Bjällmark, Anna, et al. (författare)
  • Differences in myocardial velocities during supine and upright exercise stress echocardiography in healthy adults
  • 2009
  • Ingår i: Clinical Physiology and Functional Imaging. - 1475-0961 .- 1475-097X. ; 29:3, s. 216-223
  • Tidskriftsartikel (refereegranskat)abstract
    • Tissue Velocity Imaging (TVI) is a method for quantitative analysis of longitudinal myocardial velocities, which can be used during exercise and pharmacological stress echocardiography. It is of interest to evaluate cardiac response to different types of stress tests and the differences between upright and supine bicycle exercise tests have not been fully investigated. Therefore, the aim of this study was to compare cardiac response during supine and upright exercise stress tests. Twenty young healthy individuals underwent supine and upright stress test. The initial workload was set to 30 W and was increased every minute by a further 30 W until physical exhaustion. Tissue Doppler data from the left ventricle were acquired at the end of every workload level using a GE Vivid7 Dimension system (> 200 frames s(-1)). In the off-line processing, isovolumic contraction velocity (IVCV), peak systolic velocity (PSV), isovolumic relaxation velocity (IVRV), peak early diastolic velocity (E') and peak late diastolic velocity (A') were identified at every workload level. No significant difference between the tests was found in PSV. On the contrary, E' was shown to be significantly higher (P < 0.001) during supine exercise than during upright exercise and IVRV was significantly lower (P < 0.001) during supine exercise compared to upright exercise. Upright and supine exercise stress echocardiography give a comparable increase in measured systolic velocities and significant differences in early diastolic velocities.
  •  
9.
  • Blomgren, Bo, et al. (författare)
  • A computerised, unbiased method for epithelial measurement
  • 2004
  • Ingår i: Micron. - Amsterdam : Elsevier. - 0968-4328 .- 1878-4291. ; 35, s. 319-329
  • Tidskriftsartikel (refereegranskat)abstract
    • ObjectiveTo develop and evaluate a standardised method for unbiased measurements of epithelial thickness taking the variability of the dermal papillae in consideration.MethodsA computer-assisted measurement program suitable for haematoxylin and eosin routine stained specimens has been developed.ResultsThe developed program was designed to measure four different distance parameters, taking the number, height and width of dermal papillae into account. The measurement program gave very accurate results compared with manual measurements. The measurement results can be presented as tables or star graphs, and the results can be further processed by multivariate analysis.ConclusionThe computer-assisted measurement program is considered to be a valuable and reliable tool for measurements of epithelial thickness, irrespectively of the variability of the epithelial morphology. Since length, size and number of the papillae may change with certain pathological conditions, age and also under hormonal influence, this method can be a helpful diagnostic tool.
  •  
10.
  • Chen, Hongjian, et al. (författare)
  • On the Development of a Novel Contrast Pulse Sequence for Polymer-Shelled Microbubbles
  • 2021
  • Ingår i: IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control. - : Institute of Electrical and Electronics Engineers (IEEE). - 0885-3010 .- 1525-8955. ; 68:5, s. 1569-1579
  • Tidskriftsartikel (refereegranskat)abstract
    • Contrast agents are routinely used in ultrasound examinations. Nonlinear ultrasound imaging techniques have been developed over decades to enhance the contrast between the tissue and the blood pool after the injection of ultrasound contrast agents (UCAs). In this study, we introduce a new contrast pulse sequence, CPS4. The CPS4 combines pulse inversion (PI), subharmonic (SH), and ultraharmonic (UH) techniques to remove propagation distortion while capturing the unique SH and UH responses from UCAs. The novel CPS4 and conventional PI, SH, and UH techniques were used to detect the presence of a research-grade, thick-shell, polymer microbubble in a tissue-mimicking flow phantom. The contrast-to-tissue ratios (CTRs) obtained from the applications of all techniques were compared. The results show that the highest CTR of approximately 16 dB was obtained using CPS4, which was superior to the individual reference techniques: PI, SH, and UH techniques, in all scenarios considered in this study.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 44
Typ av publikation
tidskriftsartikel (41)
forskningsöversikt (2)
konferensbidrag (1)
Typ av innehåll
refereegranskat (43)
övrigt vetenskapligt/konstnärligt (1)
Författare/redaktör
Nowak, J. (4)
Seoane, Fernando, 19 ... (4)
von Holst, Hans (2)
Gasser, T. Christian (2)
Saha, S (2)
Inganäs, Olle (1)
visa fler...
Abayazid, Fady (1)
Ding, Ke (1)
Zimmerman, Karl (1)
Stigson, Helena, 197 ... (1)
Ghajari, Mazdak (1)
Ghorbani, Morteza (1)
Chen, Hongjian (1)
Grishenkov, Dmitry, ... (1)
Theodorsson, Elvar (1)
Piehl, F (1)
Salomaa, Veikko (1)
Ollmar, S (1)
Yang, Lin (1)
Agewall, Stefan (1)
Abrahamsson, S (1)
Blom, Hans, 1968- (1)
Agostinho, A. (1)
Jans, Daniel (1)
Jost, A. (1)
Müller, M. (1)
Nilsson, Linnea (1)
Bernhem, K. (1)
Lambert, T. J. (1)
Heintzmann, R. (1)
Brismar, Hjalmar (1)
Lindecrantz, Kaj, 19 ... (1)
Janerot-Sjöberg, Bir ... (1)
Végvári, Á (1)
Beckman, Anders (1)
Carlsson Tedgren, Ås ... (1)
Jedenmalm, Anneli (1)
Kari, Leif (1)
Eyerich, K (1)
Swedenborg, J (1)
Simic, M. (1)
Wiklund, Martin (1)
Darsow, U. (1)
Stark, André (1)
Paradossi, Gaio (1)
Noz, Marilyn E. (1)
Colhoun, Helen M. (1)
Fadeel, Bengt (1)
Clyne, Naomi (1)
Frisk, Thomas (1)
visa färre...
Lärosäte
Kungliga Tekniska Högskolan (29)
Linköpings universitet (3)
Högskolan i Borås (2)
Uppsala universitet (1)
Högskolan i Halmstad (1)
visa fler...
Lunds universitet (1)
Malmö universitet (1)
Chalmers tekniska högskola (1)
Gymnastik- och idrottshögskolan (1)
RISE (1)
visa färre...
Språk
Engelska (44)
Forskningsämne (UKÄ/SCB)
Teknik (44)
Medicin och hälsovetenskap (11)
Naturvetenskap (7)
Humaniora (1)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy