SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "hsv:(TEKNIK OCH TEKNOLOGIER) hsv:(Medicinteknik) hsv:(Medicinsk laboratorie och mätteknik) ;pers:(Ask Per)"

Sökning: hsv:(TEKNIK OCH TEKNOLOGIER) hsv:(Medicinteknik) hsv:(Medicinsk laboratorie och mätteknik) > Ask Per

  • Resultat 1-10 av 16
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Ahlström, Christer, et al. (författare)
  • Detection of the 3rd Heart Sound using Recurrence Time Statistics
  • 2006
  • Ingår i: Proc. 31st IEEE Int. Conf. on Acoustics, Speech and Signal Processing, Toulouse, France, 2006. - 9781424404681 ; , s. 1040-1043
  • Konferensbidrag (övrigt vetenskapligt/konstnärligt)abstract
    • The 3rd heart sound (S3) is normally heard during auscultation of younger individuals, but it is also common in many patients with heart failure. Compared to the 1st and 2nd heart sounds, S3 has low amplitude and low frequency content, making it hard to detect (both manually for the physician and automatically by a detection algorithm). We present an algorithm based on a recurrence time statistic which is sensitive to changes in a reconstructed state space, particularly for detection of transitions with very low energy. Heart sound signals from ten children were used in this study. Most S3 occurrences were detected (98 %), but the amount of false extra detections was rather high (7% of the heart cycles). In conclusion, the method seems capable of detecting S3 with high accuracy and robustness.
  •  
2.
  • Ahlström, Christer, 1977- (författare)
  • Nonlinear phonocardiographic Signal Processing
  • 2008
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • The aim of this thesis work has been to develop signal analysis methods for a computerized cardiac auscultation system, the intelligent stethoscope. In particular, the work focuses on classification and interpretation of features derived from the phonocardiographic (PCG) signal by using advanced signal processing techniques.The PCG signal is traditionally analyzed and characterized by morphological properties in the time domain, by spectral properties in the frequency domain or by nonstationary properties in a joint time-frequency domain. The main contribution of this thesis has been to introduce nonlinear analysis techniques based on dynamical systems theory to extract more information from the PCG signal. Especially, Takens' delay embedding theorem has been used to reconstruct the underlying system's state space based on the measured PCG signal. This processing step provides a geometrical interpretation of the dynamics of the signal, whose structure can be utilized for both system characterization and classification as well as for signal processing tasks such as detection and prediction. In this thesis, the PCG signal's structure in state space has been exploited in several applications. Change detection based on recurrence time statistics was used in combination with nonlinear prediction to remove obscuring heart sounds from lung sound recordings in healthy test subjects. Sample entropy and mutual information were used to assess the severity of aortic stenosis (AS) as well as mitral insufficiency (MI) in dogs. A large number of, partly nonlinear, features was extracted and used for distinguishing innocent murmurs from murmurs caused by AS or MI in patients with probable valve disease. Finally, novel work related to very accurate localization of the first heart sound by means of ECG-gated ensemble averaging was conducted. In general, the presented nonlinear processing techniques have shown considerably improved results in comparison with other PCG based techniques.In modern health care, auscultation has found its main role in primary or in home health care, when deciding if special care and more extensive examinations are required. Making a decision based on auscultation is however difficult, why a simple tool able to screen and assess murmurs would be both time- and cost-saving while relieving many patients from needless anxiety. In the emerging field of telemedicine and home care, an intelligent stethoscope with decision support abilities would be of great value.
  •  
3.
  • Andersson, R, et al. (författare)
  • Pressure sensed non-invasively directly on the extra corporeal bloodline tube
  • 2001
  • Ingår i: PROCEEDINGS OF THE 23RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4. - 0780372115 ; , s. 3179-3181
  • Konferensbidrag (refereegranskat)abstract
    • To clinically measure blood pressure at extra corporeal bloodlines involves a hazard due to the infection risk and a risk for thrombosis formation. The aim was to design a non-invasive pressure sensor, measuring directly on a tube section. A modified tube cross-section was used to improve sensitivity. Using the developed sensing principle, a consistent relation (r=0.999) was obtained between pressure and output signal. The output was stable and an acceptable drift within the temperature-range. The method shows great promise for applications in monitoring of the dialysis process.
  •  
4.
  • Ask, Per, et al. (författare)
  • On the use of monocrystalline antimony pH electrodes in gastro-oesophageal functional disorders.
  • 1982
  • Ingår i: Medical and Biological Engineering and Computing. - 0140-0118 .- 1741-0444. ; 20:3, s. 383-389
  • Tidskriftsartikel (refereegranskat)abstract
    • Monocrystalline antimony electrodes have been shown to be suitable for thein vivo determination of pH in blood, tissue and in the upper gastro-intestinal canal. Thanks to their small dimensions it has been possible to mount them into conventional manometry catheters for oesophageal investigation. The monocrystalline antimony pH electrode has several advantages over the conventional pH glass electrode; better accuracy, shorter rise time, smaller dimensions. The monocrystalline antimony electrode has been used for long-term registration of gastro-oesophageal reflux, for the oesophageal acid clearing test and for identification of the pH gradient zone between the gastric and oesophageal mucosa. Its use in combination with pressure sensors has added a new dimension to the diagnosis of functional disorders in the gastro-oesophageal region.
  •  
5.
  •  
6.
  • Brandberg, Joakim, et al. (författare)
  • Increased accuracy of echocardiographic measurement of flow using automated spherical integration of multiple plane velocity vectors
  • 1999
  • Ingår i: Ultrasound in Medicine and Biology. - 0301-5629 .- 1879-291X. ; 25:2, s. 249-257
  • Tidskriftsartikel (refereegranskat)abstract
    • The calculation of blood flow in the heart by surface integration of velocity vectors (SIVV) using Doppler ultrasound is independent of the angle. Flow is normally calculated from velocity in a spherical thick shell with its center located at the ultrasound transducer. In a numerical simulation, we have shown that the ratio between minor and major axes of an elliptic flow area substantially influences the accuracy of the estimation of flow in a single scan plane. The accuracy of flow measurements by SIVV can be improved by calculating the mean of the values from more than one scan plane. We have produced an automated computer program that includes an antialiasing procedure. We confirmed an improvement of flow measurements in a pulsatile hydraulic flow model, the 95% confidence interval for single estimations being reduced from 20% to 10% (p < 0.05) using the newly developed software. We think that the SIVV method has important implications for clinical transthoracic echocardiography.
  •  
7.
  • Chew, Michelle, et al. (författare)
  • Pediatric cardiac output measurement using surface integration of velocity vectors : an in vivo validation study
  • 2000
  • Ingår i: Critical Care Medicine. - : Ovid Technologies (Wolters Kluwer Health). - 0090-3493 .- 1530-0293. ; 28:11, s. 3664-3671
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: To test the accuracy and reproducibility of systemic cardiac output (CO) measurements using surface integration of velocity vectors (SIVV) in a pediatric animal model with hemodynamic instability and to compare SIVV with traditional pulsed-wave Doppler measurements.Design: Prospective, comparative study.Setting: Animal research laboratory at a university medical center.Subjects: Eight piglets weighing 10-15 kg.Interventions: Hemodynamic instability was induced by using inhalation of isoflurane and infusions of colloid and dobutamine.Measurements: SIVV CO was measured at the left ventricular outflow tract, the aortic valve, and ascending aorta. Transit time CO was used as the reference standard.Results: There was good agreement between SIVV and transit time CO. At high frame rates, the mean difference ± 2 sd between the two methods was 0.01 ± 0.27 L/min for measurements at the left ventricular outflow tract, 0.08 ± 0.26 L/min for the ascending aorta, and 0.06 ± 0.25 L/min for the aortic valve. At low frame rates, measurements were 0.06 ± 0.25, 0.19 ± 0.32, and 0.14 ± 0.30 L/min for the left ventricular outflow tract, ascending aorta, and aortic valve, respectively. There were no differences between the three sites at high frame rates. Agreement between pulsed-wave Doppler and transit time CO was poorer, with a mean difference ± 2 sd of 0.09 ± 0.93 L/min. Repeated SIVV measurements taken at a period of relative hemodynamic stability differed by a mean difference ±2 sd of 0.01 ± 0.22 L/min, with a coefficient of variation = 7.6%. Intraobserver coefficients of variation were 5.7%, 4.9%, and 4.1% at the left ventricular outflow tract, ascending aorta, and aortic valve, respectively. Interobserver variability was also small, with a coefficient of variation = 8.5%.Conclusions: SIVV is an accurate and reproducible flow measurement technique. It is a considerable improvement over currently used methods and is applicable to pediatric critical care.
  •  
8.
  • Danbolt, Christina, 1946-, et al. (författare)
  • Validation and characterization of the computerized laryngeal analyzer (CLA) technique
  • 1999
  • Ingår i: Dysphagia (New York. Print). - 0179-051X .- 1432-0460. ; 14:4, s. 191-195
  • Tidskriftsartikel (refereegranskat)abstract
    • The aim of this study was to investigate the response characteristics of the Computerized Laryngeal Analyzer (CLA) and the validity of the noninvasive CLA method to detect swallowing-induced laryngeal elevation correctly. Two healthy adults and two experimental models were used in the study. The CLA technique identified all swallowing events but was unable to discriminate between swallowing and other movements of the tongue or the neck. The computer program produced a derivated response to a square wave signal. Stepwise bending increments of the sensor displayed a linear amplitude response. The degree of laryngeal elevation could not be estimated with the CLA technique, and it was not possible to draw any reliable conclusions from the recordings as to whether the larynx was moving upward or downward.
  •  
9.
  • Hult, Peter, 1964-, et al. (författare)
  • A bioacoustic method for timing of the different phases of the breathing cycle and monitoring of breathing frequency
  • 2000
  • Ingår i: Medical Engineering and Physics. - 1350-4533 .- 1873-4030. ; 22:6, s. 425-433
  • Tidskriftsartikel (refereegranskat)abstract
    • It is well known that the flow of air through the trachea during respiration causes vibrations in the tissue near the trachea, which propagate to the surface of the body and can be picked up by a microphone placed on the throat over the trachea. Since the vibrations are a direct result of the airflow, accurate timing of inspiration and expiration is possible. This paper presents a signal analysis solution for automated monitoring of breathing and calculation of the breathing frequency. The signal analysis approach uses tracheal sound variables in the time and frequency domains, as well as the characteristics of the disturbances that can be used to discriminate tracheal sound from noise. One problem associated with the bioacoustic method is its sensitivity for acoustic disturbances, because the microphone tends to pick up all vibrations, independent of their origin. A signal processing method was developed that makes the bioacoustic method clinically useful in a broad variety of situations, for example in intensive care and during certain heart examinations, where information about both the precise timing and the phases of breathing is crucial.
  •  
10.
  • Hult, Peter, 1964-, et al. (författare)
  • Detection of the third heart sound using a tailored wavelet approach
  • 2004
  • Ingår i: Medical and Biological Engineering and Computing. - 0140-0118 .- 1741-0444. ; 42:2, s. 253-258
  • Tidskriftsartikel (refereegranskat)abstract
    • The third heart sound is normally heard during auscultation of younger individuals but disappears with increasing age. However, this sound can appear in patients with heart failure and is thus of potential diagnostic use in these patients. Auscultation of the heart involves a high degree of subjectivity. Furthermore, the third heart sound has low amplitude and a low-frequency content compared with the first and second heart sounds, which makes it difficult for the human ear to detect this sound. It is our belief that it would be of great help to the physician to receive computer-based support through an intelligent stethoscope, to determine whether a third heart sound is present or not. A precise, accurate and low-cost instrument of this kind would potentially provide objective means for the detection of early heart failure, and could even be used in primary health care. In the first step, phonocardiograms from ten children, all known to have a third heart sound, were analysed, to provide knowledge about the sound features without interference from pathological sounds. Using this knowledge, a tailored wavelet analysis procedure was developed to identify the third heart sound automatically, a technique that was shown to be superior to Fourier transform techniques. In the second step, the method was applied to phonocardiograms from heart patients known to have heart failure. The features of the third heart sound in children and of that in patients were shown to be similar. This resulted in a method for the automatic detection of third heart sounds. The method was able to detect third heart sounds effectively (90%), with a low false detection rate (3.7%), which supports its clinical use. The detection rate was almost equal in both the children and patient groups. The method is therefore capable of detecting, not only distinct and clearly visible/audible third heart sounds found in children, but also third heart sounds in phonocardiograms from patients suffering from heart failure.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 16

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy