1.
  • Candefjord, Stefan, et al. (författare)
  • Combining scanning haptic microscopy and fibre optic Raman spectroscopy for tissue characterization
  • 2012
  • Ingår i: Journal of Medical Engineering & Technology. - : Taylor & Francis. - 0309-1902 .- 1464-522X. ; 36:6, s. 319-327
  • Tidskriftsartikel (refereegranskat)abstract
    • The tactile resonance method (TRM) and Raman spectroscopy (RS) are promising for tissue characterization in vivo. Our goal is to combine these techniques into one instrument, to use TRM for swift scanning, and RS for increasing the diagnostic power. The aim of this study was to determine the classification accuracy, using support vector machines, for measurements on porcine tissue and also produce preliminary data on human prostate tissue. This was done by developing a new experimental set-up combining micro-scale TRMscanning haptic microscopy (SHM)for assessing stiffness on a micro-scale, with fibre optic RS measurements for assessing biochemical content. We compared the accuracy using SHM alone versus SHM combined with RS, for different degrees of tissue homogeneity. The cross-validation classification accuracy for healthy porcine tissue types using SHM alone was 6581%, and when RS was added it increased to 8187%. The accuracy for healthy and cancerous human tissue was 6770% when only SHM was used, and increased to 7277% for the combined measurements. This shows that the potential for swift and accurate classification of healthy and cancerous prostate tissue is high. This is promising for developing a tool for probing the surgical margins during prostate cancer surgery. 
  •  
2.
  •  
3.
  • Jalkanen, Ville, 1978-, et al. (författare)
  • Explanatory models for a tactile resonance sensor system-elastic and density-related variations of prostate tissue in vitro
  • 2008
  • Ingår i: Physiological Measurement. - Bristol : IOP Publ. Ltd. - 0967-3334 .- 1361-6579. ; 29:7, s. 729-745
  • Tidskriftsartikel (refereegranskat)abstract
    • Tactile sensors based on piezoelectric resonance have been adopted for medical applications. The sensor consists of an oscillating piezoelectric sensor–circuit system, and a change in resonance frequency is observed when the sensor tip contacts a measured object such as tissue. The frequency change at a constant applied force or mass load is used as a stiffness-sensitive parameter in many applications. Differential relations between force and frequency have also been used for monitoring intraocular pressure and stiffness variations in prostate tissue in vitro. The aim of this study was to relate the frequency change (Δf), measured force (F) and the material properties, density and elasticity to an explanatory model for the resonance sensor measurement principle and thereby to give explanatory models for the stiffness parameters used previously. Simulations of theoretical equations were performed to investigate the relation between frequency change and contact impedance. Measurements with a resonance sensor system on prostate tissue in vitro were used for experimental validation of the theory. Tissue content was quantified with a microscopic-based morphometrical method. Simulation results showed that the frequency change was dependent upon density (ρ) and contact area (S) according to Δf ∝ ρS3/2. The experiments followed the simulated theory at small impression depths. The measured contact force followed a theoretical model with the dependence of the elastic modulus (E) and contact area, F ∝ ES3/2. Measured density variations related to histological variations were statistically weak or non-significant. Elastic variations were statistically significant with contributions from stroma and cancer relative to normal glandular tissue. The theoretical models of frequency change and force were related through the contact area, and a material-dependent explanatory model was found as Δf ∝ ρE−1F. It explains the measurement principle and the previously established stiffness parameters from the material properties point of view.
  •  
4.
  • Jalkanen, Ville, 1978-, et al. (författare)
  • Prostate tissue stiffness as measured with a resonance sensor system : a study on silicone and human prostate tissue in vitro.
  • 2006
  • Ingår i: Medical and Biological Engineering and Computing. - : Springer Science and Business Media LLC. - 0140-0118 .- 1741-0444. ; 44:7, s. 593-603
  • Tidskriftsartikel (refereegranskat)abstract
    • Prostate cancer is the most common form of cancer in men in Europe and in the USA. Some prostate tumours are stiffer than the surrounding normal tissue, and it could therefore be of interest to measure prostate tissue stiffness. Resonance sensor technology based on piezoelectric resonance detects variations in tissue stiffness due to a change in the resonance frequency. An impression-controlled resonance sensor system was used to detect stiffness in silicone rubber and in human prostate tissue in vitro using two parameters, both combinations of frequency change and force. Variations in silicone rubber stiffness due to the mixing ratio of the two components could be detected (p<0.05) using both parameters. Measurements on prostate tissue showed that there existed a statistically significant (MANOVA test, p<0.001) reproducible difference between tumour tissue (n=13) and normal healthy tissue (n=98) when studying a multivariate parameter set. Both the tumour tissue and normal tissue groups had variations within them, which were assumed to be related to differences in tissue composition. Other sources of error could be uneven surfaces and different levels of dehydration for the prostates. Our results indicated that the resonance sensor could be used to detect stiffness variations in silicone and in human prostate tissue in vitro. This is promising for the development of a future diagnostic tool for prostate cancer.
  •  
5.
  • Jalkanen, Ville, 1978-, et al. (författare)
  • Resonance sensor measurements of stiffness variations in prostate tissue in vitro : a weighted tissue proportion model
  • 2006
  • Ingår i: Physiological Measurement. - : IOP Publishing. - 0967-3334 .- 1361-6579. ; 27:12, s. 1373-86
  • Tidskriftsartikel (refereegranskat)abstract
    • Prostate cancer is the most common type of cancer in men in Europe and the US. The methods to detect prostate cancer are still precarious and new techniques are needed. A piezoelectric transducer element in a feedback system is set to vibrate with its resonance frequency. When the sensor element contacts an object a change in the resonance frequency is observed, and this feature has been utilized in sensor systems to describe physical properties of different objects. For medical applications it has been used to measure stiffness variations due to various patho-physiological conditions. In this study the sensor's ability to measure the stiffness of prostate tissue, from two excised prostatectomy specimens in vitro, was analysed. The specimens were also subjected to morphometric measurements, and the sensor parameter was compared with the morphology of the tissue with linear regression. In the probe impression interval 0.5-1.7 mm, the maximum R(2) > or = 0.60 (p < 0.05, n = 75). An increase in the proportion of prostate stones (corpora amylacea), stroma, or cancer in relation to healthy glandular tissue increased the measured stiffness. Cancer and stroma had the greatest effect on the measured stiffness. The deeper the sensor was pressed, the greater, i.e., deeper, volume it sensed. Tissue sections deeper in the tissue were assigned a lower mathematical weighting than sections closer to the sensor probe. It is concluded that cancer increases the measured stiffness as compared with healthy glandular tissue, but areas with predominantly stroma or many stones could be more difficult to differ from cancer.
  •  
6.
  • Lindberg, Peter L, et al. (författare)
  • An image analysis method for prostate tissue classification : preliminary validation with resonance sensor data
  • 2009
  • Ingår i: Journal of Medical Engineering & Technology. - : Informa healthcare. - 0309-1902 .- 1464-522X. ; 33:1, s. 18-24
  • Tidskriftsartikel (refereegranskat)abstract
    • Resonance sensor systems have been shown to be able to distinguish between cancerous and normal prostate tissue, in vitro. The aim of this study was to improve the accuracy of the tissue determination, to simplify the tissue classification process with computerized morphometrical analysis, to decrease the risk of human errors, and to reduce the processing time. In this article we present our newly developed computerized classification method based on image analysis. In relation to earlier resonance sensor studies we increased the number of normal prostate tissue classes into stroma, epithelial tissue, lumen and stones. The linearity between the impression depth and tissue classes was calculated using multiple linear regression (R(2) = 0.68, n = 109, p < 0.001) and partial least squares (R(2) = 0.55, n = 109, p < 0.001). Thus it can be concluded that there existed a linear relationship between the impression depth and the tissue classes. The new image analysis method was easy to handle and decreased the classification time by 80%.
  •  
7.
  •  
8.
  • Jalkanen, Ville, et al. (författare)
  • Indentation loading response of a resonance sensor : discriminating prostate cancer and normal tissue
  • 2013
  • Ingår i: Journal of Medical Engineering & Technology. - : Taylor & Francis. - 0309-1902 .- 1464-522X. ; 37:7, s. 416-423
  • Tidskriftsartikel (refereegranskat)abstract
    • Prostate cancer is the most common type of cancer among men worldwide. Mechanical properties of prostate tissue are promising for distinguishing prostate cancer from healthy prostate tissue. The aim was to investigate the indentation loading response of a resonance sensor for discriminating prostate cancer tissue from normal tissue. Indentation measurements were done on prostate tissue specimens ex vivo from 10 patients from radical prostatectomy. The measurement areas were analysed using standard histological methods. The stiffness parameter was linearly dependent on the loading force (average R2 = 0.90) and an increased loading force caused a greater stiffness contrast of prostate cancer vs normal tissue. The accuracy of the stiffness contrast was assessed by the ROC curve with the area under the curve being 0.941 for a loading force of 12.8 mN. The results are promising for the development of a resonance sensor instrument for detecting prostate cancer.
  •  
9.
  • Nyberg, Morgan, 1971-, et al. (författare)
  • Dual-modality probe intended for prostate cancer detection combining Raman spectroscopy and tactile resonance technology—discrimination of normal human prostate tissues ex vivo
  • 2015
  • Ingår i: Journal of Medical Engineering & Technology. - : Taylor & Francis. - 0309-1902 .- 1464-522X. ; 39:3, s. 198-207
  • Tidskriftsartikel (refereegranskat)abstract
    • Prostate cancer is the most common cancer for men in the western world. For the first time, a dual-modality probe, combining Raman spectroscopy and tactile resonance technology, has been used for assessment of fresh human prostate tissue. The study investigates the potential of the dual-modality probe by testing its ability to differentiate prostate tissue types ex vivo. Measurements on four prostates show that the tactile resonance modality was able to discriminate soft epithelial tissue and stiff stroma (p<0.05). The Raman spectra exhibited a strong fluorescent background at the current experimental settings. However, stroma could be discerned from epithelia by integrating the value of the spectral background. Combining both parameters by a stepwise analysis resulted in 100% sensitivity and 91% specificity. Although no cancer tissue was analysed, the results are promising for further development of the instrument and method for discriminating prostate tissues and cancer.
  •  
10.
  •  