1.
  • Eklund, Anders, et al. (författare)
  • Evaluation of applanation resonator sensors for intra-ocular pressure measurement : results from clinical and in vitro studies.
  • 2003
  • Ingår i: Medical and Biological Engineering and Computing. - 0140-0118 .- 1741-0444. ; 41:2, s. 190-197
  • Tidskriftsartikel (refereegranskat)abstract
    • Glaucoma is an eye disease that, in its most common form, is characterised by high intra-ocular pressure (IOP), reduced visual field and optic nerve damage. For diagnostic purposes and for follow-up after treatment, it is important to have simple and reliable methods for measuring IOP. Recently, an applanation resonator sensor (ARS) for measuring IOP was introduced and evaluated using an in vitro pig-eye model. In the present study, the first clinical evaluation of the same probe has been carried out, with experiments in vivo on human eyes. There was a low but significant correlation between IOP(ARS) and the IOP measured with a Goldmann applanation tonometer (r = 0.40, p = 0.001, n = 72). However, off-centre positioning of the sensor against the cornea caused a non-negligible source of error. The sensor probe was redesigned to have a spherical, instead of flat, contact surface against the eye and was evaluated in the in vitro model. The new probe showed reduced sensitivity to off-centre positioning, with a decrease in relative deviation from 89% to 11% (1 mm radius). For normalised data, linear regression between IOP(ARS) and direct IOP measurement in the vitreous chamber showed a correlation of r = 0.97 (p < 0.001, n = 108) and a standard deviation for the residuals of SD < or = 2.18 mm Hg (n = 108). It was concluded that a spherical contact surface should be preferred and that further development towards a clinical instrument should focus on probe design and signal analysis.
  •  
2.
  • Jalkanen, Ville, 1978-, et al. (författare)
  • Prostate tissue stiffness as measured with a resonance sensor system : a study on silicone and human prostate tissue in vitro.
  • 2006
  • Ingår i: Medical and Biological Engineering and Computing. - : Springer Science and Business Media LLC. - 0140-0118 .- 1741-0444. ; 44:7, s. 593-603
  • Tidskriftsartikel (refereegranskat)abstract
    • Prostate cancer is the most common form of cancer in men in Europe and in the USA. Some prostate tumours are stiffer than the surrounding normal tissue, and it could therefore be of interest to measure prostate tissue stiffness. Resonance sensor technology based on piezoelectric resonance detects variations in tissue stiffness due to a change in the resonance frequency. An impression-controlled resonance sensor system was used to detect stiffness in silicone rubber and in human prostate tissue in vitro using two parameters, both combinations of frequency change and force. Variations in silicone rubber stiffness due to the mixing ratio of the two components could be detected (p<0.05) using both parameters. Measurements on prostate tissue showed that there existed a statistically significant (MANOVA test, p<0.001) reproducible difference between tumour tissue (n=13) and normal healthy tissue (n=98) when studying a multivariate parameter set. Both the tumour tissue and normal tissue groups had variations within them, which were assumed to be related to differences in tissue composition. Other sources of error could be uneven surfaces and different levels of dehydration for the prostates. Our results indicated that the resonance sensor could be used to detect stiffness variations in silicone and in human prostate tissue in vitro. This is promising for the development of a future diagnostic tool for prostate cancer.
  •  
3.
  • Jalkanen, Ville, 1978-, et al. (författare)
  • Resonance sensor measurements of stiffness variations in prostate tissue in vitro : a weighted tissue proportion model
  • 2006
  • Ingår i: Physiological Measurement. - : IOP Publishing. - 0967-3334 .- 1361-6579. ; 27:12, s. 1373-86
  • Tidskriftsartikel (refereegranskat)abstract
    • Prostate cancer is the most common type of cancer in men in Europe and the US. The methods to detect prostate cancer are still precarious and new techniques are needed. A piezoelectric transducer element in a feedback system is set to vibrate with its resonance frequency. When the sensor element contacts an object a change in the resonance frequency is observed, and this feature has been utilized in sensor systems to describe physical properties of different objects. For medical applications it has been used to measure stiffness variations due to various patho-physiological conditions. In this study the sensor's ability to measure the stiffness of prostate tissue, from two excised prostatectomy specimens in vitro, was analysed. The specimens were also subjected to morphometric measurements, and the sensor parameter was compared with the morphology of the tissue with linear regression. In the probe impression interval 0.5-1.7 mm, the maximum R(2) > or = 0.60 (p < 0.05, n = 75). An increase in the proportion of prostate stones (corpora amylacea), stroma, or cancer in relation to healthy glandular tissue increased the measured stiffness. Cancer and stroma had the greatest effect on the measured stiffness. The deeper the sensor was pressed, the greater, i.e., deeper, volume it sensed. Tissue sections deeper in the tissue were assigned a lower mathematical weighting than sections closer to the sensor probe. It is concluded that cancer increases the measured stiffness as compared with healthy glandular tissue, but areas with predominantly stroma or many stones could be more difficult to differ from cancer.
  •  
4.
  • Lindahl, Olof A., et al. (författare)
  • Prostate cancer detection using a combination of Raman spectroscopy and stiffness sensing
  • 2014
  • Ingår i: 1st Global Conference on Biomedical Engineering &amp; 9th Asian-Pacific Conference on Medical and Biological Engineering. - New York : Encyclopedia of Global Archaeology/Springer Verlag. - 9783319122625 - 9783319122625 - 9783319122618 ; , s. 267-270
  • Konferensbidrag (refereegranskat)abstract
    • Prostate cancer (PCa) is the most common cancer form for men in Europe. A sensor system combining Raman spectroscopy and stiffness sensing with a resonance sensor has recently been developed by us for prostate cancer detection. In this study the sensor system has been used for measurements on two slices of fresh human prostate tissue. The stiffness sensor could detect locations slices with significantly different stiffness contrasts (p < 0.05). Raman spectroscopic measurements could be performed with the dual-modality probe for tissue classification. The findings are important for the continued development of a combination probe for prostate cancer detection.
  •  
5.
  • Nyberg, Morgan, 1971-, et al. (författare)
  • Dual-modality probe intended for prostate cancer detection combining Raman spectroscopy and tactile resonance technology—discrimination of normal human prostate tissues ex vivo
  • 2015
  • Ingår i: Journal of Medical Engineering & Technology. - : Taylor & Francis. - 0309-1902 .- 1464-522X. ; 39:3, s. 198-207
  • Tidskriftsartikel (refereegranskat)abstract
    • Prostate cancer is the most common cancer for men in the western world. For the first time, a dual-modality probe, combining Raman spectroscopy and tactile resonance technology, has been used for assessment of fresh human prostate tissue. The study investigates the potential of the dual-modality probe by testing its ability to differentiate prostate tissue types ex vivo. Measurements on four prostates show that the tactile resonance modality was able to discriminate soft epithelial tissue and stiff stroma (p<0.05). The Raman spectra exhibited a strong fluorescent background at the current experimental settings. However, stroma could be discerned from epithelia by integrating the value of the spectral background. Combining both parameters by a stepwise analysis resulted in 100% sensitivity and 91% specificity. Although no cancer tissue was analysed, the results are promising for further development of the instrument and method for discriminating prostate tissues and cancer.
  •  
6.
  •  
7.
  •  
8.
  • Åstrand, Anders P., et al. (författare)
  • Initial Measurements on Whole Human Prostate ex vivo with a Tactile Resonance Sensor in Order to Detect Prostate Cancer
  • 2015
  • Ingår i: 16th Nordic-Baltic Conference on Biomedical Engineering. - Cham : Springer International Publishing. - 9783319129662 - 9783319129679 ; , s. 120-123
  • Konferensbidrag (refereegranskat)abstract
    • Prostate cancer (PCa) is the most common form of cancer among the male population in Europe and the USA. PCa can be suspected by a blood test for a specific prostate antigen, a PSA-test, followed by a digital rectal examination (DRE). The objective with the DRE is to investigate the presence of stiff nodules on the prostate. Stiff nodules can indicate PCa and biopsies are taken from the suspicious parts of the prostate using guidance of a transrectal ultrasound. Microscopic evaluation of the biopsies is used for final diagnosis. Superficial tumor growth on, and beneath the surface of the gland is of special interest as it suggests that the cancer has spread to other parts of the body.Tactile resonance sensors can be used to distinguish between areas of different stiffness in soft tissue. The aim was to detect tumors on, and beneath the surface of a whole human prostate ex vivo.A tactile resonance sensor system (TRSS) based on a piezoelectric resonance sensor and a force sensor has been used to detect areas with increased stiffness in soft tissue. The TRSS has a rotatable sample holder for measurements on spherical shaped samples. Stiffness measurements were made on samples of porcine muscle tissue with embedded stiff silicone nodules placed under the surface. Further measurements were made on a resected whole human prostate with PCa.The results showed that through the measured stiffness parameter, the stiff silicone nodules placed down to 4 mm under the surface could be detected. The measurements on the prostate showed that elevated values of the stiffness parameter correlated (p < 0.05) with areas in the anterior of the prostate where cancer tumors were detected by histopathological evaluation. The tumors were significantly stiffer than the healthy tissue in the dorsal region.The results are promising for further development of a clinically useful instrument to detect superficial PCa.
  •  
9.
  •  
10.
  • Jonsson, Ulf G, 1950- (författare)
  • Detecting Inclusions in a Silicone Rubber Phantom Using Standing Lamb Waves and Multiple Frequency Footprints
  • 2014
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • The thesis deals with one major question: is it possible, using one piezoelectric sensor/vibrator, to detect a hard inclusion in a silicone rubber phantom? The question was approached with an open mind and the task was subdivided into three clearly identifiable parts: characterization of the piezoelectric sensor/vibrator (paper I), creating a model of the visco-elastic properties of a tissue-like material (phantom) in contact with the sensor/vibrator (paper II), and to detect the presence of a hard inclusion in the phantom (paper III). All vibrations of the sensor/vibrator and phantom was modeled using a finite element method (FEM). To minimize the computational time and to maximize the FEM model's ability to correctly reproduce the vibrations, a two-dimensional model system consisting of a cylindrical piezoelectric sensor/vibrator, emitting radial elastic waves in to a cylindrical disk-shaped phantom, was chosen. The piezoelectric sensor/vibrator was characterized using a parameter tuning procedure using harmonic overtones. The procedure enables tuning of the electro-elastic parameters of the sensor/vibrator so that the measured and calculated impedance frequency responses match. Silicone rubber was chosen as a phantom to mimic soft tissue. The properties of the phantom was modeled using a fractional derivative visco-elastic model. The hyperelastic effect at the first radial resonance of the sensor vibrator was corrected for by a compensating function. The high frequency complex visco-elastic modulus of the silicone rubber was determined using the transitions of standing Lamb waves in the phantom. The presence of a ring-shaped inclusion in the phantom, of polyamide, was detected using the change of the transitional Lamb wave patterns in the phantom. The tuning of the PZT5A1 sensor/vibrator parameters yielded a match between the calculated and the measured impedance spectra better than 0.54%. The average, complex, elastic modulus of three silicone rubber, Silgel 612, samples were: (0.97 + 0.009i) GPa  at 100 kHz and (0.97 + 0.005i) GPa at 250 kHz. The presence of a polyamide inclusion, PA6GPE, was detected in the phantom using multiple frequency footprints.
  •  