Error Analysis and Correction of Relative Permittivity Measured by Three-electrode System

Zhang, Yijie (författare)
Xu, Zhiniu (författare)
Jin, Hu (författare)
2018
2018
Kinesiska.
Ingår i: Gaoya Dianqi/High Voltage Apparatus. - 1001-1609. ; 54:6, s. 24-31,37
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • To improve the accuracy of the measured relative permittivity based on three-electrode system, a three-dimensional model for relative permittivity measurement is established and solved with consideration of real electrode system’s material properties and dimension by means of the finite element analysis software Comsol for multiple physical fields. In view of the nearly rotational symmetry of the electrodes system, the model is simplified to two-dimensional one to reduce computation amount. Comparison of the computation results between the 3D and 2D models verifies the reliability of the latter. Subsequently, the potential, electric field and surface charge distributions are obtained, and the error of the relative permittivity calculated by the method in a standard is calculated. The influences of sample’s thickness, relative permittivity and area (radius) on the accuracy of the calculated relative permittivity are systematically investigated, and the key factors influencing the accuracy are determined. Employing the 2D model with the sample’s thickness ranging from 0.2 to 10 mm and relative permittivity ranging from 1 to 100, the errors of relative permittivity are obtained, which are all less than zero. The relationship among sample thickness, measured relative permittivity and real value of relative permittivity is obtained, and the 2D interpolation method is used to correct the measured relative permittivity. In addition, the proposed correction method is validated by simulation and is applied to relative permittivity measurement of an insulating material.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Teknisk mekanik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Applied Mechanics (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk laboratorie- och mätteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Laboratory and Measurements Technologies (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Annan medicinteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Other Medical Engineering (hsv//eng)

Nyckelord

Error correction
Relative permittivity
Three-electrode system
Electric filed analysis
Capacitance

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Zhang, Yijie
Xu, Zhiniu
Jin, Hu
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Maskinteknik
och Teknisk mekanik
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Medicinteknik
och Medicinsk labora ...
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Medicinteknik
och Annan medicintek ...
Artiklar i publikationen
Gaoya Dianqi/Hig ...
Av lärosätet
Chalmers tekniska högskola

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy