  • Wängberg, Bo, 1953, et al. (författare)
  • Intraoperative detection of somatostatin-receptor-positive neuroendocrine tumours using indium-111-labelled DTPA-D-Phe1-octreotide.
  • 1996
  • Ingår i: British journal of cancer. - 0007-0920. ; 73:6, s. 770-5
  • Tidskriftsartikel (refereegranskat)abstract
    • After injection of 111In-labelled DTPA-D-Phe1-octreotide, intraoperative tumour localisation was performed using a scintillation detector in 23 patients with neuroendocrine tumours. Count rates from suspect tumour lesions and adjacent normal tissue were expressed as a ratio before (Rin situ) and after (Rex vivo) excision. 111In activity concentration ratios of tumour tissue to blood (T/B) were determined in a gamma counter. In patients with midgut carcinoids, (all scintigraphy positive), false Rin situ recordings were found in 4/29 macroscopically identified tumours. T/B ratios were all high (27-650). In patients with medullary thyroid carcinomas (eight out of ten scintigraphy positive), misleading Rin situ results were found in 4/37 macroscopically identified tumours. T/B ratios were lower (3-39) than those seen in midgut carcinoids. Two out of four patients with endocrine pancreatic tumours had positive scintigraphy, reliable intraoperative measurements and very high T/B ratios (910-1500). One patient with a gastric carcinoid had correct measurements in situ and ex vivo with high T/B ratios (71-210). In situ measurements added little information to preoperative scintigraphy and surgical findings using the present detection system. Rex vivo measurements were more reliable. The very high T/B ratios seen in midgut carcinoids and some endocrine pancreatic tumours would be favourable for future radiation therapy via somatostatin receptors.
  •  
3.
  • Lindh, Mats, et al. (författare)
  • Endovascular stent-anchored aortic grafts: a comparison between self-expanding and balloon-expandable stents in minipigs
  • 1996
  • Ingår i: Journal of Endovascular Surgery. - 1074-6218. ; 3:3, s. 284-289
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: To study endovascular graft attachment with self-expanding Gianturco Z-stents and balloon-expanded Palmaz stents and the effect of these devices on the renal ostia. METHODS: Ten stent-grafts were constructed, 5 with Gianturco Z-stents and 5 with Palmaz stents. The endografts were implanted under fluoroscopic guidance into the abdominal aorta of 10 pigs so that the uncovered portion of the proximal stent extended over the renal artery orifices. Distal aortic blood pressure and flow were measured before and after graft placement and 1 hour postprocedure. The aorta was then exposed surgically, and the central portion of the stent-graft was inspected through an aortotomy to assess perigraft leakage. RESULTS: Stent-graft implantation was accurate and hemostatic in all cases, despite longitudinal folding of the graft due to oversizing. However, transverse folds produced pressure gradients (> 15 mmHg) between the ends of the graft in two cases. In another case, a pressure gradient resulted from partial thrombosis of the graft. In two cases, renal artery occlusion and thrombosis occurred due to coverage by the graft material. In two other animals, one of the renal arteries was entirely uncovered by a stent. The remaining 16 renal arteries were covered by the proximal stent but not the graft, as intended. One (6.25%) of these arteries thrombosed, but the remainder were grossly patent when the animals were sacrificed at 1 hour. CONCLUSIONS: Both Palmaz and Gianturco Z-stents produced hemostatic endovascular graft attachment, even in the presence of moderate graft oversizing. The risk of acute renal artery occlusion from juxtarenal stenting does not appear to be prohibitive, but longer term observations are needed.
  •  
4.
  • Fjälling, M, et al. (författare)
  • Systemic radionuclide therapy using indium-111-DTPA-D-Phe1-octreotide in midgut carcinoid syndrome.
  • 1996
  • Ingår i: Journal of nuclear medicine : official publication, Society of Nuclear Medicine. - 0161-5505. ; 37:9, s. 1519-21
  • Tidskriftsartikel (refereegranskat)abstract
    • A 55-yr-old woman with a midgut carcinoid syndrome due to metastatic spread of an ileal tumor to the liver, paraortic and mediastinal lymph nodes and to the skeleton was given systemic radionuclide therapy with 111In-DTPA-D-Phe1-octreotide. Before therapy, dosimetric calculations were performed on whole-body scintigraphs and 111In retention was shown to be long-lasting. Excretion was mainly seen during the first 24 hr after injection; thereafter whole-body retention remained stationary at 30%. Indium-111 activity in tumor biopsies and blood was measured using a gamma counter. Very high tumor-to-blood ratios were obtained: 150 for the primary tumor and 400-650 for liver metastases, which further justified radiation therapy. Indium-111-DTPA-D-Phe1-octreotide treatment was given on three separate occasions (3.0, 3.5 and 3.1 GBq) 8 and 4 wk apart. After each therapy, the patient experienced facial flush and pain over the skeletal lesions followed by symptomatic relief, even though no objective tumor regression was found radiologically after 5 mo. After initiation of octreotide treatment, there was a 14% reduction of the main tumor marker, urinary 5-HIAA. After three subsequent radionuclide therapies, there was a further 31% reduction of 5-HIAA levels. No adverse reactions, other than a slight decrease in leukocyte counts, were seen. The mean absorbed radiation dose after the three treatments was estimated to be about 10-12 Gy in liver metastases and 3-6 Gy in other tumors, depending on the size and location of the metastases. Assuming internalization of 111In into tumor cells and a radiobiological effect from short range Auger and conversion electrons, there might be a therapeutic effect on the tumor.
  •  
5.
  •  
6.
  •  
7.
  • Önsten, Ingemar, et al. (författare)
  • Migration and wear of a hydroxyapatite-coated hip prosthesis. A controlled roentgen stereophotogrammetric study
  • 1996
  • Ingår i: Journal of Bone and Joint Surgery: British Volume. - 2044-5377. ; 78:1, s. 85-91
  • Tidskriftsartikel (refereegranskat)abstract
    • A consecutive series of 30 total hip replacements using a hydroxyapatite (HA)-coated, modular implant (Omnifit) was followed clinically and by roentgen stereophotogrammetric analysis for two years and compared with two control groups, one of 27 cemented Charnley sockets and one of 40 cemented Charnley stems. Omnifit sockets with a central gap between the dome of the socket and the acetabular bone in the postoperative radiographs, migrated less than sockets without such gaps (p = 0.01). After adjustment for patient-related factors (age, gender and weight), no significant difference was found between the two prostheses with respect to micromotion and wear. We conclude that the early fixation of the HA-coated Omnifit prosthesis compares with that of the cemented Charnley prosthesis.
  •  
8.
  • Blad, Börje, et al. (författare)
  • Impedance spectra of tumour tissue in comparison with normal tissue; a possible clinical application for electrical impedance tomography
  • 1996
  • Ingår i: Physiological Measurement. - 0967-3334. ; 17, s. 105-115
  • Tidskriftsartikel (refereegranskat)abstract
    • Electrical characteristics of living tissues have been investigated for a long time in the search for further methods to complement the traditional investigations of pathology and physiology. Tumour tissue has been shown to exhibit a larger permittivity and conductivity than normal tissues. This might be associated with the fact that tumour cells have a higher water content and sodium concentration than normal cells, as well as different electrochemical properties of their cell membranes. To our knowledge only a few contributions on this subject have been published. This study describes an additional application on measurements of the complex impedance of tumour and normal tissues, in order to compare the impedance features of the two tissue types. The tissue sample is placed in a measuring cell in which the temperature is controlled. The measuring cell is connected to an impedance meter able to measure the complex impedance in terms of real and imaginary part curves for frequencies from 1.5 kHz to 700 kHz. The four-electrode principle is used with the current injected by the outer electrodes and the voltage difference measured between the inner electrodes. The current can be altered up to 1 mA. The instrument can be calibrated with known resistance and capacitance networks connected to the input of the instrument in order to minimize the measurement errors. The calibration routine uses a polynomial adaptation and can be applied interactively. Measurements performed by the instrument show promising results. Preliminary results show that this method can be extended to a new application for detection of tumour tissue by electrical impedance tomography (EIT).
  •  
9.
  •  
10.
  • Akeson, P, et al. (författare)
  • MR imaging in recurrent pain after back surgery. A comparative study using standard and high doses of gadolinium contrast agents
  • 1996
  • Ingår i: Acta Radiologica. - 1600-0455. ; 37:6, s. 858-858
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: To compare the diagnostic results following injection of (a) a high dose (0.3 mmol/kg b.w.) of gadodiamide injection and (b) the standard dose (0.1 mmol/kg b.w.) of Gd-DTPA, in patients with recurrent symptoms after surgery for lumbar disc herniation. MATERIAL AND METHODS: Twenty patients with recurrent or sustained symptoms after surgery for lumbar disc herniations were examined. MR imaging (0.3 T) was first performed before and after Gd-DTPA at 0.1 mmol/kg b.w., and then within one month (17 patients) or within 3 months (3 patients) before and after gadodiamide injection at 0.3 mmol/kg b.w. The examinations were first evaluated by 2 neuroradiologists blinded to dose but not to patient as the images were presented in pairs. Six months later the same investigators evaluated the examinations again, this time blinded to both dose and patient. RESULTS: At the evaluation in pairs (with the investigators blinded to dose only) the high-dose examinations were considered the most informative (p=0.05). However, at the later evaluation (with the investigators blinded both to dose and patient) no significant difference between high and standard dose was found regarding diagnosis or diagnostic certainty. CONCLUSION: In this study the high-dose contrast enhancement of MR imaging at 0.3 T did not increase the diagnostic information for differentiating between scar and recurrent hernia. The high-dose images were considered more informative when evaluated in pairs, but gave no additional or different information when evaluated separately. The study also indicated that comparisons in pairs should be interpreted with caution.
  •  