SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "hsv:(MEDICIN OCH HÄLSOVETENSKAP) hsv:(Medicinsk bioteknologi) hsv:(Annan medicinsk bioteknologi) srt2:(2000-2004)"

Sökning: hsv:(MEDICIN OCH HÄLSOVETENSKAP) hsv:(Medicinsk bioteknologi) hsv:(Annan medicinsk bioteknologi) > (2000-2004)

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Jergil, Bengt, et al. (författare)
  • Purification of plasma membranes by affinity partitioning
  • 2000
  • Ingår i: Aqueous Two-Phase Systems : Methods and Protocols - Methods and Protocols. - New Jersey : Humana Press. - 1940-6061. - 9780896035416 - 9781592590285 ; 11, s. 193-200
  • Bokkapitel (övrigt vetenskapligt/konstnärligt)
  •  
2.
  • Juntikka, Rickard, et al. (författare)
  • Optimization of single skin surfaces for head injury prevention - a comparison of optima calculated for global versus local injury thresholds
  • 2004
  • Ingår i: International Journal of Crashworthiness. - : Informa UK Limited. - 1358-8265 .- 1754-2111. ; 9:4, s. 365-379
  • Tidskriftsartikel (refereegranskat)abstract
    • This paper describes optimizations of material properties for a bonnet-like plate using finite element calculations and the Euro-NCAP pedestrian head impact test. Four different head models were used for the impact simulations, a Euro-NCAP dummy head, a Hybrid III dummy head and two biomechanical head models exhibiting different mechanical properties for the brain tissue. The objective function was to minimize the displacement of the bonnet plate while satisfying constraints on the head injury criterion (HIC), the resultant contact force and, for the human head models, the strain in the brain tissue. An investigation was also conducted of the kinematics of the head models during impact, evaluating the energy distribution and the apparent mass. The analysis gave at hand that optimization of the plate with respect to impact with the Euro-NCAP and Hybrid III head models reached substantially, different results compared to impact with the biomechanical head models. For the latter case, the stiffness of the brain tissue influenced which constraints were active in the final solution. The investigation of the kinematics at impact showed that a substantial portion of energy was confined within the brain during impact for the biomechanical head models. The apparent mass at impact coincided with the actual mass for the rigid dummy heads while for the human head models it was roughly the mass of the skull only.
  •  
3.
  • Waligórski, Michael P R, et al. (författare)
  • Cellular parameters and RBE-LET dependences for modelling heavy-ion radiotherapy.
  • 2004
  • Ingår i: Radiother Oncol. - : Elsevier BV. - 0167-8140 .- 1879-0887. ; 73:Supplement 2, s. S173-175
  • Tidskriftsartikel (refereegranskat)abstract
    • Sets of four parameters (m, Eo, ~o and •) of the cellular track structure model of Katz have been fitted to recently published dataconcerning human melanoma (AA) and mammalian (V79) cells exposed to a variety of lighter ions and to mixed ion-Co60 and ionionirradiation. We discuss the predictive capability of this model and propose standards in reporting cellular radiobiology data forapplication in modelling heavy ion beam radiotherapy.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy