Validity and comparability of a wrist-worn accelerometer in children.

Ekblom, Örjan, 1971- (författare)
Gymnastik- och idrottshögskolan,Björn Ekbloms forskningsgrupp
Nyberg, Gisela (författare)
Karolinska Institutet
Ekblom Bak, Elin (författare)
Gymnastik- och idrottshögskolan,Björn Ekbloms forskningsgrupp
visa fler...
Ekelund, Ulf (författare)
Cambridge University,MRC Epidemiology
Marcus, Claude (författare)
Karolinska Institutet
visa färre...
 (creator_code:org_t)
Human Kinetics, 2012
2012
Engelska.
Ingår i: Journal of Physical Activity and Health. - : Human Kinetics. - 1543-3080 .- 1543-5474. ; 9:3, s. 389-393
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • BACKGROUND:Wrist-worn accelerometers may provide an alternative to hip-worn monitors for assessing physical activity as they are easier to wear and may thus facilitate long-term recordings. The current study aimed at a) assessing the validity of the Actiwatch (wrist-worn) for estimating energy expenditure, b) determining cut-off values for light, moderate, and vigorous activities, c) studying the comparability between the Actiwatch and the Actigraph (hip-worn), and d) assessing reliability.METHODS:For validity, indirect calorimetry was used as criterion measure. ROC-analyses were applied to identify cut-off values. Comparability was tested by simultaneously wearing of the 2 accelerometers during free-living condition. Reliability was tested in a mechanical shaker.RESULTS:All-over correlation between accelerometer output and energy expenditure were found to be 0.80 (P < .001).Based on ROC-analysis, cut-off values for 1.5, 3, and 6 METs were found to be 80, 262, and 406 counts per 15 s, respectively. Energy expenditure estimates differed between the Actiwatch and the Actigraph (P < .05). The intra- and interinstrument coefficient of variation of the Actiwatch ranged between 0.72% and 8.4%.CONCLUSION:The wrist-worn Actiwatch appears to be valid and reliable for estimating energy expenditure and physical activity intensity in children aged 8 to 10 years.

Nyckelord

Medicin/Teknik
Medicine/Technology

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy