Sökning: id:"swepub:oai:DiVA.org:hb-7345" >
Development and pre...
Development and preliminary evaluation of an Android based heart rate variability biofeedback system
-
- Abtahi, Farhad, 1981- (författare)
- KTH,Högskolan i Borås,Institutionen för Vårdvetenskap,Medicinska sensorer, signaler och system,Kungliga Tekniska Högskolan (KTH),Royal Institute of Technology (KTH)
-
- Berndtsson, Andreas (författare)
- Högskolan i Borås,Institutionen för Vårdvetenskap,Kungliga Tekniska Högskolan (KTH),Royal Institute of Technology (KTH)
-
- Abtahi, Shirin (författare)
- Högskolan i Borås,Institutionen för Vårdvetenskap,Chalmers tekniska högskola,Chalmers University of Technology
-
visa fler...
-
- Seoane, Fernando (författare)
- KTH,Högskolan i Borås,Institutionen för Vårdvetenskap,Medical TexTTronics,Medicinska sensorer, signaler och system,University of Borås
-
- Lindecrantz, Kaj (författare)
- KTH,Medicinska sensorer, signaler och system,Medical TexTTronics,Karolinska Institutet,Kungliga Tekniska Högskolan (KTH),Royal Institute of Technology (KTH)
-
visa färre...
-
(creator_code:org_t)
- IEEE, 2014
- 2014
- Engelska.
-
Ingår i: Engineering in Medicine and Biology Society (EMBC), 2014 36th Annual International Conference of the IEEE. - : IEEE. - 9781424479290 ; 2014, s. 3382-5
- Relaterad länk:
-
http://ieeexplore.ie...
-
visa fler...
-
https://urn.kb.se/re...
-
https://doi.org/10.1...
-
https://urn.kb.se/re...
-
https://research.cha...
-
http://kipublication...
-
visa färre...
Abstract
Ämnesord
Stäng
- The reduced Heart Rate Variability (HRV) is believed to be associated with several diseases such as congestive heart failure, diabetes and chronic kidney diseases (CKD). In these cases, HRV biofeedback may be a potential intervention method to increase HRV which in turn is beneficial to these patients. In this work, a real-time Android biofeedback application based on a Bluetooth enabled ECG and thoracic electrical bioimpedance (respiration) measurement device has been developed. The system performance and usability have been evaluated in a brief study with eight healthy volunteers. The result demonstrates real-time performance of system and positive effects of biofeedback training session by increased HRV and reduced heart rate. Further development of the application and training protocol is ongoing to investigate duration of training session to find an optimum length and interval of biofeedback sessions to use in potential interventions.
Ämnesord
- TEKNIK OCH TEKNOLOGIER -- Elektroteknik och elektronik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Electrical Engineering, Electronic Engineering, Information Engineering (hsv//eng)
- TEKNIK OCH TEKNOLOGIER -- Elektroteknik och elektronik -- Datorsystem (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Electrical Engineering, Electronic Engineering, Information Engineering -- Computer Systems (hsv//eng)
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine (hsv//eng)
Nyckelord
- personalized healhcare
- pervasive healthcare
- Biomedical Engineering
- Integrated Caring Science
- Integrerad vårdutveckling
Publikations- och innehållstyp
- ref (ämneskategori)
- kon (ämneskategori)
Hitta via bibliotek
Till lärosätets databas