SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:hh-30366"
 

Sökning: id:"swepub:oai:DiVA.org:hh-30366" > Turbulence influenc...

Turbulence influence on wind energy extraction for a medium size vertical axis wind turbine

Möllerström, Erik, 1984- (författare)
Uppsala universitet,Högskolan i Halmstad,Energiteknik,Uppsala University, Uppsala, Sweden,Elektricitetslära,Halmstad Univ, Dept Construct & Energy Engn, POB 823, SE-30118 Halmstad, Sweden
Ottermo, Fredric, 1975- (författare)
Högskolan i Halmstad,Energiteknik,Halmstad Univ, Dept Construct & Energy Engn, POB 823, SE-30118 Halmstad, Sweden
Goude, Anders (författare)
Uppsala universitet,Elektricitetslära,Uppsala University, Uppsala, Sweden
visa fler...
Eriksson, Sandra S. (författare)
Uppsala universitet,Elektricitetslära,Uppsala University, Uppsala, Sweden
Hylander, Jonny, 1955- (författare)
Högskolan i Halmstad,Energiteknik,Halmstad Univ, Dept Construct & Energy Engn, POB 823, SE-30118 Halmstad, Sweden
Bernhoff, Hans (författare)
Uppsala universitet,Elektricitetslära,Uppsala University, Uppsala, Sweden
visa färre...
 (creator_code:org_t)
2016-02-18
2016
Engelska.
Ingår i: Wind Energy. - Chichester : John Wiley & Sons. - 1095-4244 .- 1099-1824. ; 19:11, s. 1963-1973
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The relation between power performance and turbulence intensity for a VAWT H-rotor is studied using logged data from a 14 month (discontinuous) period with the H-rotor operating in wind speeds up to 9 m/s. The turbine, designed originally for a nominal power of 200 kW, operated during this period mostly in a restricted mode due to mechanical concerns, reaching power levels up to about 80 kW. Two different approaches are used for presenting results, one that can be compared to power curves consistent with the International Electrotechnical Commission (IEC) standard and one that allows isolating the effect of turbulence from the cubic variation of power with wind speed. Accounting for this effect, the turbine still shows slightly higher efficiency at higher turbulence, proposing that the H-rotor is well suited for wind sites with turbulent winds. The operational data are also used to create a Cp(λ) curve, showing slightly lower Cp compared with a curve simulated by a double multiple streamtube model. Copyright © 2016 John Wiley & Sons, Ltd.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Energiteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Energy Engineering (hsv//eng)

Nyckelord

VAWT
H-rotor
turbulence intensity
power coefficient curve

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy