SwePub
Sök i LIBRIS databas

  Extended search

id:"swepub:oai:DiVA.org:hh-48986"
 

Search: id:"swepub:oai:DiVA.org:hh-48986" > Bond performance of...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Bond performance of tensile lap-spliced basalt-FRP reinforcement in high-strength concrete beams

Eltantawi, I. (author)
Qatar University, Doha, Qatar
Alnahhal, W. (author)
Qatar University, Doha, Qatar
El Refai, A. (author)
Laval University, Quebec, Canada
show more...
Younis, Adel, 1990- (author)
Linnéuniversitetet,Institutionen för byggteknik (BY),Linnaeus University, Växjö, Sweden
Alnuaimi, N. (author)
Qatar University, Doha, Qatar
Kahraman, R. (author)
Qatar University, Doha, Qatar
show less...
 (creator_code:org_t)
Elsevier BV, 2022
2022
English.
In: Composite structures. - : Elsevier BV. - 0263-8223 .- 1879-1085. ; 281
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • This paper investigates the bond between high-strength concrete (HSC) and tensile lap-spliced basalt fiber-reinforced polymer (BFRP) bars. Ten large-scale BFRP-reinforced concrete beams (300 × 450 × 3900 mm) were fabricated and tested under four-point loading until failure. The parameters investigated included the BFRP bar diameter (10, 12, and 16 mm), the splice length (400–1200 mm range), and the bar surface texture (sand-coated (SC) and helically wrapped (HW)). Test results demonstrated that the flexural capacity of the beams reinforced with SC-BFRP bars was almost similar to that of beams reinforced with HW-BFRP bars. However, SC-BFRP bars showed a slightly higher bond with concrete compared to that of helically wrapped counterparts. The bond strength of spliced BFRP bars was inversely related to the splice length. Also, BFRP bars with larger diameter bars require longer splice lengths to reach their maximum capacity. Finally, the experimentally estimated critical splice lengths were compared to those calculated by existing models and code-based equations. Both ACI 440.1R-15 and CSA S806-12 provisions were conservative in predicting splice length for BFRP bars. However, the CSA-S6-14 design code was more accurate in estimating the splice length for BFRP with bigger diameters. Though, it was not conservative with smaller diameters.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Samhällsbyggnadsteknik -- Husbyggnad (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Civil Engineering -- Building Technologies (hsv//eng)

Keyword

Lap-splice
Fiber reinforced polymer (FRP)
Basalt FRP bars
High-strength concrete
Reinforced concrete beams
Bond
Byggteknik

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view