Sökning: id:"swepub:oai:DiVA.org:hig-26500" >
Comparing different...
Comparing different building energy efficiency refurbishment packages performed within different district heating systems
-
- Lidberg, Tina, 1982- (författare)
- Högskolan i Gävle,Energisystem,Högskolan Dalarna,Energiteknik,Dalarna University, Sweden
-
- Swing Gustafsson, Moa (författare)
- Högskolan Dalarna; KTH,Dalarna University, Sweden; KTH Royal Institute Technology, Sweden
-
- Myhren, Jonn Are, 1979- (författare)
- Högskolan Dalarna,Byggteknik,Dalarna University, Sweden
-
visa fler...
-
- Olofsson, Thomas (författare)
- Högskolan Dalarna,Umeå universitet,Institutionen för tillämpad fysik och elektronik,Dalarna Univ, Sch Technol & Business Studies, SE-79188 Falun, Sweden,Högskolan Dalarna; Umeå universitet,Energiteknik,Dalarna University, Sweden; Umeå University, Sweden
-
- Trygg, Louise (författare)
- Linköpings universitet,Energisystem,Tekniska fakulteten
-
- Gustafsson, Marcus (författare)
- Högskolan Dalarna,KTH,Strömnings- och klimatteknik,Dalarna University, Sweden,Energiteknik
-
visa färre...
-
(creator_code:org_t)
- Elsevier BV, 2017
- 2017
- Engelska.
-
Ingår i: Energy Procedia. - : Elsevier BV. - 1876-6102. ; 105, s. 1719-1724, s. 1719-1724, s. 1719-1724
- Relaterad länk:
-
https://doi.org/10.1...
-
visa fler...
-
https://doi.org/10.1...
-
https://umu.diva-por... (primary) (Raw object)
-
https://du.diva-port... (primary) (Raw object)
-
https://urn.kb.se/re...
-
https://doi.org/10.1...
-
https://urn.kb.se/re...
-
https://urn.kb.se/re...
-
https://urn.kb.se/re...
-
https://urn.kb.se/re...
-
visa färre...
Abstract
Ämnesord
Stäng
- This study analyses the differences in primary energy (PE) use of a multi-family building refurbished with different refurbishment packages situated in different district heating systems (DHS). Four models of typical DHS are defined to represent the Swedish DH sector. The refurbishment packages are chosen to represent typical, yet innovative ways to improve the energy efficiency of a representative multi-family building in Sweden. The study was made from a broad system perspective, including valuation of changes in electricity use on the margin. The results show a significant difference in PE savings for the different refurbishment packages, depending on both the package itself as well as the type of DHS. Also, the package giving the lowest specific energy use per m2 was not the one which saved the most PE. © 2017 The Authors.
Ämnesord
- TEKNIK OCH TEKNOLOGIER -- Samhällsbyggnadsteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Civil Engineering (hsv//eng)
- TEKNIK OCH TEKNOLOGIER -- Naturresursteknik -- Energisystem (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Environmental Engineering -- Energy Systems (hsv//eng)
- TEKNIK OCH TEKNOLOGIER -- Maskinteknik -- Energiteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Mechanical Engineering -- Energy Engineering (hsv//eng)
Nyckelord
- building simulation
- District heating
- energy efficient refurbishment
- multi-family building
- primary energy
- Sustainable Urban Development
- Hållbar stadsutveckling
- Energy and Built Environments
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas