SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:hig-27633"
 

Sökning: id:"swepub:oai:DiVA.org:hig-27633" > Disturbance observe...

Disturbance observer based dynamic load torque compensator for assistive exoskeletons

Masud, Nauman (författare)
KTH,Högskolan i Gävle,Elektronik,Department of Robotics, Perception and Learning, Royal Institute of Technology, Stockholm, Sweden,Robotik, perception och lärande, RPL,Univ Gävle, Dept Elect Math & Sci, S-80176 Gävle, Sweden
Smith, Christian (författare)
KTH,Robotik, perception och lärande, RPL,Department of Robotics, Perception and Learning, Royal Institute of Technology, Stockholm, Sweden
Isaksson, Magnus (författare)
Högskolan i Gävle,Elektronik,Univ Gävle, Dept Elect Math & Sci, S-80176 Gävle, Sweden.
 (creator_code:org_t)
Elsevier Ltd, 2018
2018
Engelska.
Ingår i: Mechatronics (Oxford). - : Elsevier Ltd. - 0957-4158 .- 1873-4006. ; 54, s. 78-93
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • In assistive robotics applications, the human limb is attached intimately to the robotic exoskeleton. The coupled dynamics of the human-exoskeleton system are highly nonlinear and uncertain, and effectively appear as uncertain load-torques at the joint actuators of the exoskeleton. This uncertainty makes the application of standard computed torque techniques quite challenging. Furthermore, the need for safe human interaction severely limits the gear ratio of the actuators. With small gear ratios, the uncertain joint load-torques cannot be ignored and need to be effectively compensated. A novel disturbance observer based dynamic load-torque compensator is hereby proposed and analysed for the current controlled DC-drive actuators of the exoskeleton, to effectively compensate the said uncertain load-torques at the joint level. The feedforward dynamic load-torque compensator is proposed based on the higher order dynamic model of the current controlled DC-drive. The dynamic load-torque compensator based current controlled DC-drive is then combined with a tailored feedback disturbance observer to further improve the compensation performance in the presence of drive parametric uncertainty. The proposed compensator structure is shown both theoretically and practically to give significantly improved performance w.r.t disturbance observer compensator alone and classical static load-torque compensator, for rated load-torque frequencies up to 1.6 Hz, which is a typical joint frequency bound for normal daily activities for elderly. It is also shown theoretically that the proposed compensator achieves the improved performance with comparable reference current requirement for the current controlled DC-drive.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik -- Robotteknik och automation (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering -- Robotics (hsv//eng)

Nyckelord

Disturbance observer
Exoskeleton
Load torque compensator
Serial manipulator
Actuators
DC motors
Dynamic loads
Electric machine control
Electric machine theory
Joints (anatomy)
Manipulators
Robotics
Torque
Torque measurement
Application of standards
Compensation performance
Compensator structure
Higher-order dynamics
Load torques
Parametric uncertainties
Serial manipulators
Exoskeleton (Robotics)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy