SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:hig-42966"
 

Sökning: id:"swepub:oai:DiVA.org:hig-42966" > Mechanical and Post...

Mechanical and Postfire Structural Performances of Concrete under Elevated Temperatures

Murugan, Vishal (författare)
SRM Institute of Science and Technology, SRM Nagar, Kattankulathur, Tamil Nadu-603203, India.
Bahrami, Alireza (författare)
Högskolan i Gävle,Energisystem och byggnadsteknik
Srivastava, Rakshit (författare)
SRM Institute of Science and Technology, SRM Nagar, Kattankulathur, Tamil Nadu-603203, India.
visa fler...
Satyanarayanan, K. S. (författare)
SRM Institute of Science and Technology, SRM Nagar, Kattankulathur, Tamil Nadu-603203, India.
Murugan, Prakash (författare)
SRM Institute of Science and Technology, SRM Nagar, Kattankulathur, Tamil Nadu-603203, India.
Arvind, J. S. (författare)
Design Group Engineering Consultant LLC, Muscat, Oman
visa färre...
SRM Institute of Science and Technology, SRM Nagar, Kattankulathur, Tamil Nadu-603203, India Energisystem och byggnadsteknik (creator_code:org_t)
CEJ, 2023
2023
Engelska.
Ingår i: Civil Engineering Journal. - : CEJ. - 2676-6957 .- 2476-3055. ; 9:8, s. 1863-1879
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • This article investigates the mechanical and postfire structural performances of concrete under elevated temperatures (200°C, 400°C, 600°C, and 800°C) after 7 and 28 days of concrete curing. The main objective of this study is to evaluate the post-fire behavior of concrete structures and how their modulus of elasticity values influence their structural parameters. Mechanical studies, namely, the compressive strength, splitting tensile strength, and flexural strength, were performed on cubes, cylinders, and prism beams under normal and elevated temperatures. Non-destructive tests, like rebound hammer and ultrasonic pulse velocity, were also conducted on concrete cubes to obtain the strength of concrete before and after heating the specimens. Microstructural studies, in particular, scanning electron microscope and energy dispersive x-ray spectroscopy, were done to analyze the changes in the chemical composition of concrete under the effect of the temperatures. The weight loss of the concrete specimens was assessed under the elevated temperatures. The results indicated that the geometric shapes of the specimens influenced the loss in the moisture content of concrete under an elevated temperature scenario. Microstructural studies revealed the changes in the chemical composition under the elevated temperatures. The results of this research can be further integrated for industrial applications.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Samhällsbyggnadsteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Civil Engineering (hsv//eng)

Nyckelord

Post-Fire Structural Performance; Elevated Temperature; Geometric Shape; Mechanical Behavior; Microstructural Studies.

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy