Sökning: id:"swepub:oai:DiVA.org:hj-42472" >
A vibrotactile and ...
A vibrotactile and plantar force measurement-based biofeedback system : Paving the way towards wearable balance-improving devices
-
- Ma, Christina Zong-Hao (författare)
- Interdisciplinary Division of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong
-
- Wan, Anson H. -P (författare)
- Interdisciplinary Division of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong
-
- Wong, Duo W.-C. (författare)
- Interdisciplinary Division of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong
-
visa fler...
-
- Zheng, Yong-Ping (författare)
- Interdisciplinary Division of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong
-
- Lee, Winson C.-C. (författare)
- Interdisciplinary Division of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong
-
visa färre...
-
(creator_code:org_t)
- 2015-12-15
- 2015
- Engelska.
-
Ingår i: Sensors. - : MDPI. - 1424-8220. ; 15:12, s. 31709-31722
- Relaterad länk:
-
https://doi.org/10.3...
-
visa fler...
-
https://www.mdpi.com...
-
https://urn.kb.se/re...
-
https://doi.org/10.3...
-
visa färre...
Abstract
Ämnesord
Stäng
- Although biofeedback systems have been used to improve balance with success, they were confined to hospital training applications. Little attempt has been made to investigate the use of in-shoe plantar force measurement and wireless technology to turn hospital training biofeedback systems into wearable devices. This research developed a wearable biofeedback system which detects body sway by analyzing the plantar force and provides users with the corresponding haptic cues. The effects of this system were evaluated in thirty young and elderly subjects with simulated reduced foot sensation. Subjects performed a Romberg test under three conditions: (1) no socks, system turned-off; (2) wearing five layers of socks, system turned-off; (3) wearing five layers of socks, and system turned-on. Degree of body sway was investigated by computing the center of pressure (COP) movement measured by a floor-mounted force platform. Plantar tactile sensation was evaluated using a monofilament test. Wearing multiple socks significantly decreased the plantar tactile sensory input (p < 0.05), and increased the COP parameters (p < 0.017), indicating increased postural sway. After turning on the biofeedback system, the COP parameters decreased significantly (p < 0.017). The positive results of this study should inspire future development of wearable plantar force-based biofeedback systems for improving balance in people with sensory deficits.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Hälsovetenskap -- Arbetsterapi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Health Sciences -- Occupational Therapy (hsv//eng)
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Ortopedi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Orthopaedics (hsv//eng)
Nyckelord
- Balance
- Biofeedback
- Elderly
- Falls
- Plantar force measurement
- Postural stability
- Sensory augmentation
- Wearable device
- Balancing
- Force measurement
- Hospitals
- Wearable technology
- Wireless telecommunication systems
- Sensory augmentations
- Wearable devices
- adult
- aged
- ambulatory monitoring
- body equilibrium
- clinical trial
- devices
- falling
- female
- foot
- human
- male
- physiology
- prevention and control
- procedures
- shoe
- young adult
- Accidental Falls
- Biofeedback
- Psychology
- Humans
- Monitoring
- Ambulatory
- Postural Balance
- Shoes
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
-
Sensors
(Sök värdpublikationen i LIBRIS)
Till lärosätets databas