Experimental studies on simultaneous removal of CO2 and SO2 in a polypropylene hollow fiber membrane contactor

Lv, Yuexia (author)
Yu, Xinhai (author)
E China Univ Sci & Technol, Shanghai
Tu, Shan-Tung (author)
E China Univ Sci & Technol, Shanghai
show more...
Yan, Jinyue (author)
Mälardalens högskola,KTH,Energiprocesser,Akademin för hållbar samhälls- och teknikutveckling
Dahlquist, Erik (author)
Mälardalens högskola,Akademin för hållbar samhälls- och teknikutveckling
Lu, Yuexia, 1983- (author)
Mälardalens högskola,Akademin för hållbar samhälls- och teknikutveckling
show less...
 (creator_code:org_t)
Elsevier BV, 2012
2012
English.
In: Applied Energy. - : Elsevier BV. - 0306-2619 .- 1872-9118. ; 97, s. 283-288
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Membrane gas absorption technology is a promising alternative to conventional technologies for the mitigation of acid gases. In this study, simultaneous removal of SO2 and CO2 from coal-fired flue gas was carried out in a polypropylene hollow fiber membrane contactor using aqueous monoethanolamine as the absorbent. The influences of liquid and gas flow rates on the simultaneous absorption performance of CO2 and SO2 were investigated. The experimental results indicated that the membrane contactor could eliminate these two sour gases simultaneously and effectively. Absorption of SO2 and CO2 was enhanced by the increase in liquid flow rate and decrease in gas flow rate. It was observed that a small amount of SO2 in the flue gas had a slight influence on the absorption of CO2. In addition, the membrane contactor was operated continuously for two weeks to evaluate its duration performance. The results showed that the CO2 mass transfer rate was decreased significantly with the operating time due to partial wetting of membrane pores. After 14 days of continuous operation, the CO2 mass transfer rate of the wetted membrane contactor was decreased by 41% but could be retrieved to 86% of the fresh one by increasing the gas phase pressure.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Naturresursteknik -- Energisystem (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Environmental Engineering -- Energy Systems (hsv//eng)

Keyword

Simultaneous absorption
CO2 capture
SO2 removal
Membrane contactor
Partial wetting
Energy- and Environmental Engineering

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view