SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:kth-122233"
 

Sökning: id:"swepub:oai:DiVA.org:kth-122233" > Ultrasonic Quantifi...

Ultrasonic Quantification of Skeletal Muscle Dynamics : Feasibility and Limitations

Lindberg, Frida, 1982- (författare)
KTH,Medicinsk teknik
Brodin, Lars-Åke, Professor (preses)
KTH,Medicinsk teknik
Grönlund, Christer, Docent (preses)
Medicinsk Teknik - FoU, Umeå Universitet
visa fler...
Jansson, Tomas, Docent (opponent)
Elektrisk mätteknik, Lunds Universitet
visa färre...
 (creator_code:org_t)
ISBN 9789175017372
Stockholm : KTH Royal Institute of Technology, 2013
Engelska x, 54 s.
Serie: Trita-STH : report, 1653-3836 ; 2013:4
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)
Abstract Ämnesord
Stäng  
  • Pain and disorders of the human skeletal muscles are one of the most common reasons for medical consultations in the western countries today and there is a great need to improve both the understanding and treatment of several different muscular conditions.Techniques describing the muscle function in vivo are often limited by either their invasiveness or lack of spatial resolution. Electromyography (EMG) is the most common approach to assess the skeletal muscle function in vivo, providing information on the neurological input. However, the spatial resolution is in general limited and there are difficulties reaching deep musculature without using invasive needles. Moreover, it does not provide any information about muscle structure or mechanical aspects.Quantitative ultrasound techniques have gained interest in the area of skeletal muscles and enables non-invasive and in-vivo insight to the intramuscular activity, through the mechanical response of the activation. However, these techniques are developed and evaluated for cardiovascular applications and there are important considerations to be made when applying these methods in the musculoskeletal field. This thesis is based on the work from four papers with the main focus to investigate and describe some of these considerations in combination with the development of processing and analyzing methods that can be used to describe the physiological characteristics of active muscle tissue.In the first paper the accuracy of the Doppler based technique Tissue Velocity Imaging (TVI) was evaluated in a phantom study for very low tissue velocities and the effect of the pulse repetition frequency was considered. The second paper presents a biomechanical model to describe the TVI strain’s dependency on the muscle fiber pennation angle. In the third and fourth papers the intramuscular activity pattern was assessed through the regional tissue deformation by motion mode (M-mode) strain imaging. The activity patterns were analyzed during force regulation and for the effects of fatigue.The work of this thesis show promising results for the application of these methods on skeletal muscles and indicate high clinical potential where quantitative ultrasound may be a valuable tool to reach a more multifaceted and comprehensive insight in the musculoskeletal function. However, the methodological considerations are highly important for the optimized application and further evaluation and development of analyzing strategies are needed.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk bildbehandling (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Image Processing (hsv//eng)

Nyckelord

ultrasound
skeletal muscle
intramuscular
dynamics
Tissue Doppler Imaging
Speckle Tracking
strain
quantification

Publikations- och innehållstyp

vet (ämneskategori)
dok (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy