SwePub
Sök i LIBRIS databas

  Extended search

id:"swepub:oai:DiVA.org:kth-136104"
 

Search: id:"swepub:oai:DiVA.org:kth-136104" > Multiaxial mechanic...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Multiaxial mechanical properties and constitutive modeling of human adipose tissue : A basis for preoperative simulations in plastic and reconstructive surgery

Sommer, G. (author)
Eder, M. (author)
Kovacs, L. (author)
show more...
Pathak, H. (author)
Bonitz, L. (author)
Mueller, C. (author)
Regitnig, P. (author)
Holzapfel, Gerhard (author)
KTH,Hållfasthetslära (Inst.),Institute of Biomechanics, Center of Biomedical Engineering, Graz University of Technology, Austria
show less...
KTH Hållfasthetslära (Inst(creator_code:org_t)
Elsevier BV, 2013
2013
English.
In: Acta Biomaterialia. - : Elsevier BV. - 1742-7061 .- 1878-7568. ; 9:11, s. 9036-9048
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • A preoperative simulation of soft tissue deformations during plastic and reconstructive surgery is desirable to support the surgeon's planning and to improve surgical outcomes. The current development of constitutive adipose tissue models, for the implementation in multilayer computational frameworks for the simulation of human soft tissue deformations, has proved difficult because knowledge of the required mechanical parameters of fat tissue is limited. Therefore, for the first time, human abdominal adipose tissues were mechanically investigated by biaxial tensile and triaxial shear tests. The results of this study suggest that human abdominal adipose tissues under quasi-static and dynamic multiaxial loadings can be characterized as a nonlinear, anisotropic and viscoelastic soft biological material. The nonlinear and anisotropic features are consequences of the material's collagenous microstructure. The aligned collagenous septa observed in histological investigations causes the anisotropy of the tissue. A hyperelastic model used in this study was appropriate to represent the quasi-static multiaxial mechanical behavior of fat tissue. The constitutive parameters are intended to serve as a basis for soft tissue simulations using the finite element method, which is an apparent method for obtaining promising results in the field of plastic and reconstructive surgery.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Industriell bioteknik -- Biomaterial (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Industrial Biotechnology -- Bio Materials (hsv//eng)

Keyword

Biaxial tensile test
Constitutive parameters
Human abdominal adipose tissue
Multiaxial mechanical properties
Triaxial shear test

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view