Removing respiratory artefacts from transthoracic bioimpedance spectroscopy measurements

Cuba-Gyllensten, Illapha (författare)
KTH,Skolan för teknik och hälsa (STH),Philips Research Europe, High Tech. Campus 34, 5656AE, Eindhoven, Netherlands; ACTLab., Signal Processing Systems, TU Eindhoven, 5600MB Eindhoven, Netherlands
Abtahi, Farhad (författare)
Philips Research Europe, High Tech. Campus 34, 5656AE, Eindhoven, Netherlands
Bonomi, Alberto Giovanni. (författare)
KTH,Skolan för teknik och hälsa (STH)
visa fler...
Lindecrantz, Kaj (författare)
KTH,Medicinska sensorer, signaler och system,University of Borås, Sweden
Seoane, Fernando (författare)
KTH,Medicinska sensorer, signaler och system,Karolinska Institute, Sweden
Amft, O. (författare)
ACTLab., Signal Processing Systems, TU Eindhoven, 5600MB Eindhoven, Netherlands
visa färre...
 (creator_code:org_t)
2013-04-18
2013
Engelska.
Ingår i: XV International Conference on Electrical Bio-Impedance (ICEBI) & XIV Conference on Electrical Impedance Tomography (EIT). - : Institute of Physics Publishing (IOPP).
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • Transthoracic impedance spectroscopy (TIS) measurements from wearable textile electrodes provide a tool to remotely and non-invasively monitor patient health. However, breathing and cardiac processes inevitably affect TIS measurements, since they are sensitive to changes in geometry and air or fluid volumes in the thorax. This study aimed at investigating the effect of respiration on Cole parameters extracted from TIS measurements and developing a method to suppress artifacts. TIS data were collected from 10 participants at 16 frequencies (range: 10 kHz - 1 MHz) using a textile electrode system (Philips Technologie Gmbh). Simultaneously, breathing volumes and frequency were logged using an electronic spirometer augmented with data from a breathing belt. The effect of respiration on TIS measurements was studied at paced (10 and 16 bpm) deep and shallow breathing. These measurements were repeated for each subject in three different postures (lying down, reclining and sitting). Cole parameter estimation was improved by assessing the tidal expiration point thus removing breathing artifacts. This leads to lower intra-subject variability between sessions and a need for less measurements points to accurately assess the spectra. Future work should explore algorithmic artifacts compensation models using breathing and posture or patient contextual information to improve ambulatory transthoracic impedance measurements.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Annan medicinteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Other Medical Engineering (hsv//eng)

Nyckelord

Air
Artificial intelligence
Electric impedance
Electric impedance tomography
Parameter estimation
Patient monitoring
Textiles

Publikations- och innehållstyp

ref (ämneskategori)
kon (ämneskategori)

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Cuba-Gyllensten, ...
Abtahi, Farhad
Bonomi, Alberto ...
Lindecrantz, Kaj
Seoane, Fernando
Amft, O.
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Medicinteknik
och Annan medicintek ...
Artiklar i publikationen
Av lärosätet
Kungliga Tekniska Högskolan

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy