SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:kth-14266"
 

Sökning: id:"swepub:oai:DiVA.org:kth-14266" > Effect of head surf...

Effect of head surface roughness and sterilization method on wear of UHMWPE acetabular cups : preliminary hip joint simulator results

Jedenmalm, Anneli (författare)
KTH,Materialvetenskap
Leardini, Walther (författare)
Laboratorio di Tecnologia Medica, Istititi Ortppedci Rizzoli, Bologna
Zavalloni, Mara (författare)
Laboratorio di Tecnologia Medica, Istititi Ortppedci Rizzoli, Bologna
visa fler...
Affatato, Saverio (författare)
Laboratorio di Tecnologia Medica, Istititi Ortppedci Rizzoli, Bologna
visa färre...
 (creator_code:org_t)
2008-09-05
2006
Engelska.
Ingår i: Proceedings of 8th Biennial ASME Conference on Engineering Systems Design and Analysis, ESDA2006, Vol. 3. - : ASMEDC. - 9780791837795
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • More than one million hip joint replacements are performed each year in the world. However, the implants do not last forever due to material limitations, even though the operation is successful. The most common material combination used today is a CoCr head articulating against an UHMWPE (Ultra High Molecular Weight Polyethylene) acetabular cup. Several investigations have shown that the metal head is roughened inside the body and thus accelerating wear of the polymer cup. The sterilization method is also known to have effect on the wear properties. In vitro wear tests are however usually performed with as new implants. This investigation aimed at study the impact of head surface roughness on wear of both sterilized and non-sterilized acetabular cups. A total of nine acetabular cup and head pairs were wear tested in a hip joint simulator for 2Million cycles (Mc) with bovine calf serum as lubricant. Wear was determined by weighing of all cups. The heads were of CoCrMo and the average initial head surface roughness was 15nm (R-a), measured with a white light interference profilometer. The roughening was produced with a SiC paper producing circular multidirectional wear tracks to a surface roughness of about 400nm (R-a). The cups were of UHMWPE and the sterilized cups were 3Mrad gamma-radiated in nitrogen. The surface roughness after wear test was unchanged for the roughened heads, while the initially smooth heads were slightly roughened. Preliminary results show that the rough heads increase the wear of the cups 2-fold. The gamma-irradiation affected both wear- and soak rate.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk laboratorie- och mätteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Laboratory and Measurements Technologies (hsv//eng)

Nyckelord

Hip prostheses; Hip simulator; Roughened femoral heads; Surface roughness; UHMWPE; Wear
Medical engineering
Medicinsk teknik

Publikations- och innehållstyp

ref (ämneskategori)
kon (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy