Electrical bioimpedance spectroscopy in time-variant systems : Is undersampling always a problem?

Abtahi, Farhad (författare)
KTH,Medicinska sensorer, signaler och system
Seoane, Fernando (författare)
Högskolan i Borås,KTH,Medicinska sensorer, signaler och system,Institutionen Ingenjörshögskolan,Medical TexTTronics
Lindecrantz, Kaj (författare)
Högskolan i Borås,KTH,Medicinska sensorer, signaler och system,Institutionen Ingenjörshögskolan,Medical TexTTronics
 (creator_code:org_t)
2014-04-18
2014
Engelska.
Ingår i: Journal of Electrical Bioimpedance. - : Walter de Gruyter GmbH. - 1891-5469. ; 5:1, s. 28-33
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • During the last decades, Electrical Bioimpedance Spectroscopy (EBIS) has been applied mainly by using the frequency-sweep technique, across a range of many different applications. Traditionally, the tissue under study is considered to be time-invariant and dynamic changes of tissue activity are ignored by treating the changes as a noise source. A new trend in EBIS is simultaneous electrical stimulation with several frequencies, through the application of a multi-sine, rectangular or other waveform. This method can provide measurements fast enough to sample dynamic changes of different tissues, such as cardiac muscle. This high sampling rate comes at a price of reduction in SNR and the increase in complexity of devices. Although the frequency-sweep technique is often inadequate for monitoring the dynamic changes in a variant system, it can be used successfully in applications focused on the time-invariant or slowly-variant part of a system. However, in order to successfully use frequency-sweep EBIS for monitoring time-variant systems, it is paramount to consider the effects of aliasing and especially the folding of higher frequencies, on the desired frequency e.g. DC level. This paper discusses sub-Nyquist sampling of thoracic EBIS measurements and its application in the case of monitoring pulmonary oedema. It is concluded that by considering aliasing, and with proper implementation of smoothing filters, as well as by using random sampling, frequency-sweep EBIS can be used for assessing time-invariant or slowly-variant properties of time-variant biological systems, even in the presence of aliasing. In general, undersampling is not always a problem, but does always require proper consideration.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk apparatteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Equipment Engineering (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik -- Signalbehandling (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering -- Signal Processing (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Medicinsk bioteknologi -- Biomedicinsk laboratorievetenskap/teknologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Medical Biotechnology -- Biomedical Laboratory Science/Technology (hsv//eng)

Nyckelord

Electrical bioimpedance spectroscopy
Aliasing in thoracic impedance spectroscopy
frequency-sweep EBIS
Thoracic Impedance Measurements
sub-Nyquist sampling
Medical Technology
Medicinsk teknologi
Electrical Engineering
Elektro- och systemteknik
Integrated Caring Science

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy