Standard orientation of the pelvis : Validation on a model and ten patients

Olivecrona, Lotta (författare)
Karolinska Institutet, Department of Clinical Science, Intervention and Technology, Division of Radiology
Aspelin, Peter (författare)
Karolinska Institutet
Weidenhielm, Lars (författare)
Karolinska Institutet
visa fler...
Stark, Andreas (författare)
Karolinska Institutet
Noz, Marilyn E. (författare)
New York University, Department of Radiology,Nuclear Medicine
Maguire Jr., Gerald Q. (författare)
KTH,Kommunikationssystem, CoS,Computer Communications
Zeleznik, Michael P. (författare)
RAHD Oncol Prod, St Louis, MO USA
Svensson, Lars E. (författare)
KTH,Matematik (Inst.)
Olivecrona, Henrik (författare)
Soder Sjukhuset, Dept Hand Surgery
visa färre...
 (creator_code:org_t)
2016-08-30
2005
Engelska.
Ingår i: Acta Radiologica. - London, UK : Informa Healthcare. - 0284-1851 .- 1600-0455. ; 46:1, s. 74-82
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Purpose: To validate an image post-processing method for re-orienting the pelvis in CT volumes to a standardized orientation in a model and in 10 patients. Material and Methods: Twenty-four CT volumes of a pelvic model and 10 pairs of postoperative total hip arthroplasty (THA) patient CT scans were rotated to a defined pelvic standard orientation and the rotation was recorded. For precision, a test-retest procedure was used. For accuracy, three exactly represented coordinate points were used. For clinical application, the standard orientation was used for calculating the direction of acetabular cup migration from a previous model study. Results: Precision of pelvic standard orientation, calculated as maximal directional error, was better than 1degrees in the model study and better than 1.5degrees in the patient study. Accuracy, expressed as angle between ideal and measured coordinate axes, was 0.1degrees for x, y, z axes. No measurable systematic errors were found. When applied to acetabular cup migration in the model, standardization of pelvic orientation had no significant effect on the measurements. Conclusion: Reorienting the pelvis during image post-processing was shown to be accurate. It enables measurements relative to the pelvis and minimizes the dependency of patient positioning.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

CT
hip
arthroplasty
total hip-arthroplasty
acetabular component migration
semiautomated program
computed-tomography
ct
fusion
cup
anteversion
alignment
SRA - ICT
SRA - Informations- och kommunikationsteknik

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy